1. Introduction

The EBYTE EID051 Series RS485 Serial Port LED Display is a robust industrial-grade digital tube display designed for various communication and monitoring applications. It supports the MODBUS RTU protocol, enabling flexible display of integers, floating-point numbers, and ASCII characters. This manual provides detailed instructions for the installation, operation, and maintenance of your EID051-133 (3 Digits 0.36 inch) display.

2. Key Features

  • RS485 Communication: Supports MODBUS RTU protocol for industrial communication.
  • Versatile Display: Capable of displaying integers, positive/negative numbers, decimal points, floating-point numbers, and various ASCII characters.
  • Electronic Labeling: Features a power-on customized display content function, ideal for electronic labeling (e.g., "A-01", "B-02").
  • Adjustable Brightness: Offers 8 phases of brightness adjustment for optimal visibility in different environments.
  • Configurable Parameters: Allows modification of Modbus address (1-255), baud rate (1200bps-115200bps), and check digit.
  • Power-on Customization: Set initial display content upon power-on (e.g., 0, 485 address, specified content, all segments lit).
  • Blinking Function: Configurable blinking display for specific digits or the entire display, with adjustable cycle.
  • Industrial-Grade Protection: Built-in switching power supply with reverse connection and overcurrent protection. Industrial-grade RS485 chip with lightning, surge, anti-static, over-voltage, and over-current protection.
  • Wide Operating Temperature: Stable operation in extreme conditions from -45°C to 85°C.
  • Built-in Watchdog: Ensures stable and continuous operation without crashing.
  • EMC Level 3 Certification: Ports can resist 8KV electrostatic air discharge.
  • Easy Installation: Designed for embedded panel mounting, requiring only square holes and no installation screws.
  • Host Computer Software: Supporting software provided for testing and parameter modification.

3. Setup and Installation

Follow these steps for proper installation of your EID051 display.

3.1 Physical Installation

The EID051 display is designed for embedded panel mounting. Cut a square hole in your device panel according to the dimensions provided in the specifications section. Insert the display into the opening; it will secure itself without the need for additional screws.

EID051 Series Display Dimensions

Figure 3.1: Dimensions for EID051-133/134/135/143/144/145 (top) and EID051-138/148 (bottom) models. The EID051-133 (3 Digits 0.36 inch) model corresponds to the smaller unit shown at the top, with approximate dimensions of 60.3mm x 28.8mm for the front panel and 15mm depth.

3.2 Wiring

Connect the power supply and RS485 communication lines to the display's terminals. Ensure correct polarity for the power supply, as the device includes reverse connection protection. Refer to the product's pinout diagram (if available, otherwise general RS485 A/B and power +/- connections).

  • Power Supply: Connect to the designated power input terminals. The device features a wide input voltage range.
  • RS485 Communication: Connect the RS485 A and B lines to the corresponding terminals.

4. Operating Instructions

This section details how to configure and operate your EID051 display using the Modbus RTU protocol.

4.1 Modbus RTU Communication

The display communicates via Modbus RTU. Ensure your master device (e.g., PLC, HMI) is configured with matching communication parameters (Modbus address, baud rate, check digit).

  • Modbus Address: Can be set from 1 to 255. This address identifies the display on the RS485 bus.
  • Baud Rate: Supports standard rates from 1200bps to 115200bps.
  • Check Digit: Configurable parity settings (e.g., None, Even, Odd).

Refer to the specific Modbus register map provided with the product documentation for details on writing data to display and configuring parameters.

4.2 Display Customization

The EID051 offers several options for customizing its display behavior.

  • Brightness Adjustment: The display supports 8 levels of brightness. This can typically be adjusted via Modbus commands or potentially through the host computer software.
  • EID051 Display with 8 Brightness Levels

    Figure 4.1: The EID051 display offers 8 distinct brightness levels, allowing users to adjust visibility according to environmental conditions and preferences.

  • Power-on Initial Display: Configure what the display shows immediately after power-up. Options include displaying '0', the device's 485 address, a specified custom content, or having all digital tube segments lit.
  • Blinking Function: Activate blinking for specific digits or the entire display. The blinking cycle can be customized to user habits and site requirements.

4.3 Host Computer Software

EBYTE provides supporting host computer software to facilitate testing, parameter modification, and restoration of factory settings. This software offers a user-friendly interface for managing the display's configurations.

5. Maintenance

The EID051 display is designed for industrial environments and requires minimal maintenance.

  • Cleaning: Gently wipe the display surface with a soft, dry cloth. Avoid using abrasive cleaners or solvents that could damage the display or casing.
  • Environmental Conditions: Ensure the operating environment remains within the specified temperature and humidity ranges (-45°C to 85°C).
  • Firmware Updates: Check the EBYTE official website periodically for any available firmware updates that may enhance performance or add new features.

6. Troubleshooting

If you encounter issues with your EID051 display, refer to the following common troubleshooting steps.

ProblemPossible CauseSolution
Display is blank or off.No power, incorrect wiring, or power supply issue.Verify power connections and supply voltage. Check for reverse polarity.
Incorrect or garbled display.Modbus communication parameters mismatch, incorrect data format.Check Modbus address, baud rate, and check digit settings on both the display and the master device. Ensure data sent is in the correct format (e.g., ASCII, integer).
Display not responding to commands.Modbus address conflict, wiring issue, or master device problem.Confirm unique Modbus address. Inspect RS485 wiring for continuity and shorts. Test with host computer software if available.
Display flickers or is unstable.Power supply instability, electromagnetic interference (EMI).Ensure stable power supply. Check for sources of EMI and consider shielding or grounding improvements.
EID051 Display with Built-in Watchdog

Figure 6.1: The EID051 series features a built-in watchdog timer to prevent system crashes and ensure stable, continuous operation, reducing the need for constant supervision.

EID051 Display with EMC Level 3 Protection

Figure 6.2: The EID051 display is designed with EMC level 3 certification, providing robust protection against electrostatic discharge up to 8KV, enhancing reliability in industrial environments.

7. Specifications

Detailed technical specifications for the EID051-133 (3 Digits 0.36 inch) display.

ParameterValue
BrandEBYTE
ModelEID051-133 (3 Digits 0.36 inch)
Communication ProtocolRS485, MODBUS RTU
Display TypeLED Digital Tube
Digit Count3 Digits
Digit Size0.36 inch
Baud Rate1200bps - 115200bps
Modbus Address Range1 - 255
Brightness Levels8 phases
Operating Temperature-45°C to 85°C
Protection FeaturesReverse connection, overcurrent, lightning, surge, anti-static, over-voltage
EMC CertificationLevel 3 (8KV electrostatic air discharge resistance)
MountingEmbedded Panel Mount
Parcel Dimensions19 x 13 x 6 cm
Weight100 g
EID051 Display Industrial Grade Quality

Figure 7.1: The EID051 display is built to industrial-grade quality standards, ensuring stable operation within a wide temperature range of -45°C to 85°C, suitable for demanding environments.

8. Warranty and Support

For warranty information and technical support, please refer to the documentation provided with your purchase or visit the official EBYTE website. Contact details for customer service are typically available on the product packaging or the manufacturer's website.

Related Documents - EID051-133 (3 Digits 0.36 inch)

Preview EBYTE MA01/MA02-AXCX4040 无线调制解调器用户手册
EBYTE MA01/MA02-AXCX4040 用户手册提供了关于这款4路数字输入(DI)和4路数字输出(DO)的串口I/O联网模块的详细信息。该模块支持Modbus RTU协议,适用于工业自动化、远程数据采集和控制应用。
Preview EBYTE NE2 Series Serial Port Server AT Command Set
This document provides the AT command set for the EBYTE NE2 Series Serial Port Servers, covering basic functions, Modbus functions, and IoT functions. It details commands for configuration, network settings, communication protocols, and device management.
Preview 亿佰特 ZigBee 3.0 系列 HEX 模式串口命令指南
本指南详细介绍了亿佰特(EBYTE)ZigBee 3.0 系列模块的 HEX 模式串口通信命令。内容涵盖了串口格式、命令帧结构、命令类型、网络管理命令(ZDO)以及 ZCL 协议命令的解析,是开发和集成 EBYTE ZigBee 模块的必备参考文档。
Preview EBYTE 多串口服务器 AT 指令集
本手册详细介绍了 EBYTE 多串口服务器的 AT 指令集,涵盖基本功能、Modbus 功能和物联网功能,帮助用户配置和管理设备。
Preview EWM108-GN05 Command Manual for GNSS Module
This manual provides comprehensive instructions for using commands with the EWM108-GN05 GNSS module from Chengdu Ebyte Electronic Technology. It details command formats, serial port configuration, NMEA data output, satellite system selection, parameter saving, and special pin functions for firmware updates.
Preview NB124 Dual Serial Port Server User Manual
This user manual provides comprehensive instructions for the NB124 Dual Serial Port Server, a 2-way serial port server that integrates TCP/IP protocol for transparent data transmission between serial ports and Ethernet. It covers product introduction, quick start guide, technical parameters, basic and advanced functions, working modes, and firmware upgrades.