Introduction
The LIDER Programmable Digital Timer Switch provides automated control for indoor and outdoor lighting, fans, and motors. This 7-day timer offers up to 18 ON/OFF settings, enhancing energy efficiency and home security. It is designed for 1-pole applications and does not require a neutral wire, making it suitable for various electrical installations. This manual provides detailed instructions for installation, setup, operation, and troubleshooting.
Safety Information
WARNING: To avoid fire, shock, or death, turn off power at the circuit breaker or fuse box and test that the power is off before wiring. This device must be installed in accordance with all national and local electrical codes.
- Always turn off power at the circuit breaker before installation or servicing.
- A ground wire is required for proper operation and safety.
- Do not use with appliances that could cause dangerous conditions if activated unexpectedly (e.g., sunlamps, saunas, heaters).
- Ensure the total bulb wattage exceeds 5W for proper operation.
- GFCI/AFCI circuits might disrupt normal timer operation. Verify compatibility if present.
Package Contents
- LIDER Programmable Digital Timer Switch
- Wall Plate
- Wire Nuts
- Instruction Manual
Specifications
| Model | LTS-7D-G-LAWP |
| Voltage | 120V, 60Hz |
| Resistive Load | 15A |
| Tungsten Load | 1200W |
| Ballast Load | 1200W |
| Motor Load | 1/2 HP |
| Number of Settings | 18 ON/OFF programs |
| Wiring | 1-Pole, No Neutral Wire Required, Ground Wire Required |
| Material | Polycarbonate Thermoplastic |
| Certifications | UL Listed |
Installation
Follow these steps for safe and correct installation of your LIDER Digital Timer Switch.
- Turn Off Power: Locate the circuit breaker or fuse box controlling the switch you are replacing. Turn off the power completely. Verify the power is off using a voltage tester.
- Prepare Wiring: This timer switch requires a Line (Hot), Load, and Ground connection. It does not require a neutral wire. Identify these wires in your electrical box. The timer has three pigtail leads: Black (Hot), Red (Load), and Green (Ground).
- Connect Wires: Use the provided wire nuts to connect the timer's wires to your household wiring:
- Connect the timer's Black wire to the Line (Hot) wire from your electrical box.
- Connect the timer's Red wire to the Load wire (leading to the light/fan).
- Connect the timer's Green wire to the Ground wire in your electrical box.
Important: Ensure the Line (Hot) and Load wires are connected correctly. Reversing them will prevent the timer from functioning.

Image: Wiring diagram for the LIDER timer switch, illustrating connections for Hot (Black), Load (Red), and Ground wires.
- Mount the Timer: Carefully push the wired timer into the electrical box. Secure it with the mounting screws. Attach the wall plate.
- Restore Power & Warm-Up: Turn the power back on at the circuit breaker. The timer requires a warm-up period of approximately 1-2 minutes after installation before the display activates. Do not be alarmed if the screen remains blank initially.

Image: Visual guide showing installation steps and the warm-up process for the timer switch.
This timer is ideal for homes built before the mid-1980s that may lack a neutral wire in the switch box.

Image: The LIDER timer switch installed in a residential setting, emphasizing its 'No Neutral Wire Required' feature.
Initial Setup
After the warm-up period, the display will show the current time and day. If not, you may need to set them.

Image: The LIDER timer switch with its protective cover open, revealing the programming buttons.

Image: A detailed diagram labeling each button on the LIDER timer switch and its corresponding function.
- Set Current Time: Press the HOUR button to adjust the hour and the MIN button to adjust the minute. Hold the buttons for faster adjustment.
- Set Current Day: Press the DAY button to select the current day of the week.
- Daylight Saving Time (DST): Press the HOUR/DST button to toggle DST on or off.
Operating Instructions
Programming ON/OFF Schedules
The timer allows for up to 18 ON/OFF programs per day. Each program consists of an ON time and an OFF time.
- Press the PROG button to enter programming mode. The display will show '1 ON'.
- Use the HOUR and MIN buttons to set the desired ON time for program 1.
- Press the DAY button to select the day(s) of the week for this program. You can choose individual days, weekdays, weekends, or all 7 days.
- Press PROG again. The display will show '1 OFF'. Set the desired OFF time for program 1 using HOUR, MIN, and DAY buttons.
- Repeat steps 2-4 for additional programs (2 ON/OFF through 18 ON/OFF).
- To exit programming mode, press the MODE/RCL button. The timer will return to normal operation.
Manual Override
To temporarily override the programmed schedule, press the MAN button. This will cycle through ON, OFF, and AUTO modes. In AUTO mode, the timer follows the programmed schedule.
Random Mode for Security
The random mode feature can deter intruders by turning lights on and off at varying, unpredictable times when you are away.
- To activate random mode, press the MIN/RND button. The display will show 'RND'.
- In random mode, the timer will turn connected devices ON and OFF randomly within a set time window around your programmed schedules.
- To deactivate random mode, press the MIN/RND button again.
The LIDER timer switch offers versatile control for various applications, including porch lights, patio lighting, fans, and even automated aquarium lighting.

Image: Timer switch controlling porch lights.

Image: Timer switch controlling patio lighting.

Image: Timer switch automating aquarium lighting.
Maintenance
The LIDER Digital Timer Switch is designed for minimal maintenance. To ensure longevity and proper function:
- Clean the surface with a soft, damp cloth. Avoid abrasive cleaners or solvents.
- Do not attempt to open or repair the device. Refer servicing to qualified personnel.
- The internal battery (for timekeeping during power outages) is not user-replaceable.
Troubleshooting
Common Issues and Solutions
- Timer Switch Shows No Response After Installation (Blank Screen):
- Ensure Line (Hot) and Load wires are not reversed. Correct wiring is crucial.
- Verify the ground wire is securely connected to the switch or the junction box's grounding screw.
- Check if the light fixture or connected device is faulty.
- Allow 1-2 minutes for the device to warm up after power restoration.
- Lights/Fans Do Not Turn ON/OFF According to Schedule:
- Ensure the timer is in AUTO mode (not Manual ON or Manual OFF).
- Review your programmed schedules for correct ON/OFF times and selected days.
- Check if the current time and day are set correctly on the timer.
- Deactivate Random Mode if it's causing unexpected variations.
- Buttons Are Unresponsive:
- Perform a soft reset by pressing the recessed RESET button (usually requires a small pointed object like a paperclip). This will clear all settings, and you will need to reprogram the timer.
Warranty and Support
LIDER products typically come with a standard 1-year warranty from the date of purchase. For potential warranty extension to 2 years, please refer to the product packaging or LIDER's official website for specific instructions and requirements, usually involving registration within 90 days of purchase.
For technical support, warranty claims, or further assistance, please contact LIDER customer service through their official website or the contact information provided with your product packaging.