1. Introduction

Thank you for choosing the Duluth Forge DLS-N24T-2 Ventless Natural Gas Log Set. This product is designed to provide efficient supplemental heating and a realistic fireplace ambiance without the need for a chimney or vent. Please read this manual thoroughly before installation and operation to ensure safe and proper use.

Duluth Forge Ventless Natural Gas Log Set installed in a fireplace, showing realistic flames and logs.

Image 1: Duluth Forge DLS-N24T-2 Ventless Natural Gas Log Set in operation.

2. Safety Information

WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information, consult a qualified installer, service agency, or the gas supplier.

  • This appliance is for indoor use only.
  • Do not install this appliance in a bathroom or bedroom.
  • Ensure adequate ventilation in the room where the appliance is installed.
  • The appliance must be installed in a masonry or agency approved firebox.
  • Minimum firebox size required: 20 inches (H) x 28 inches (W) in front (23 inches W at rear) x 15 inches (D).
  • Equipped with an Oxygen Depletion Sensor (O.D.S.) that automatically shuts off the unit if oxygen levels drop.
  • Professional installation by a certified gas technician is highly recommended to ensure safety and maintain warranty validity.
  • Keep children and pets away from the appliance when in operation.
  • Do not place clothing or other flammable materials on or near the appliance.

3. What's in the Box

Verify that all components are present and undamaged before proceeding with installation.

  • U-Burner Chassis - Qty. 1
  • Hand Painted Ceramic Fiber Logs - Qty. 8
  • Bag of Embers - Qty. 1
  • Hardware Pack - Qty. 1
  • User Manual - Qty. 1
Components of the Duluth Forge Ventless Gas Log Set, including the burner chassis, logs, and a bag of embers.

Image 2: All components included in the package.

4. Setup

4.1 Firebox Preparation

Ensure your firebox meets the minimum size requirements: 20 inches (H) x 28 inches (W) in front (23 inches W at rear) x 15 inches (D). The firebox must be clean and free of debris.

Diagram showing the dimensions of the Duluth Forge Ventless Gas Log Set and the minimum required firebox dimensions.

Image 3: Product dimensions and minimum firebox requirements.

4.2 Gas Line Connection

Connect the gas line to the U-burner chassis. This step requires a qualified gas technician to ensure proper and safe connection to your natural gas supply. Improper connection can lead to gas leaks and serious hazards.

4.3 Log Placement

Carefully arrange the 8 ceramic fiber logs on the burner chassis according to the diagram provided in the detailed user manual. The logs are designed to fit together like a puzzle, ensuring optimal flame appearance and heat distribution. Do not block any burner ports or air inlets.

Close-up of the Duluth Forge Ventless Gas Log Set showing the arrangement of the hand-painted ceramic logs and glowing embers.

Image 4: Detailed view of log placement and ember bed.

4.4 Ember Material Application

Distribute the glowing ember material from the provided bag evenly over the burner pan, avoiding direct contact with the burner ports. This enhances the realistic glowing effect.

4.5 Battery Installation

Install 1 AAA battery (included) into the battery-assisted Piezo ignition system. Refer to the manual for the exact location of the battery compartment.

5. Operation

5.1 Ignition

To ignite the log set, turn the control knob to the 'PILOT' position and press it in. While holding, press the Piezo igniter button repeatedly until the pilot flame ignites. Continue to hold the control knob for approximately 60 seconds to allow the thermocouple to heat up. Release the knob; if the pilot extinguishes, repeat the process. Once the pilot is stable, turn the control knob to the desired heat setting (1-5).

Close-up of the thermostat control knob and electronic Piezo ignition button on the Duluth Forge gas log set.

Image 5: Thermostat control and Piezo ignition.

5.2 Thermostatic Control

The DLS-N24T-2 features a built-in thermostat control. Once set to a desired temperature, the burner will automatically cycle on and off to maintain the room temperature, providing consistent and efficient heating.

5.3 Heat Output

This unit provides 33,000 BTU of heat, capable of heating up to 1,300 sq. ft. It operates on natural gas, offering 99.9% efficiency without the need for an outside duct or chimney.

Duluth Forge Ventless Gas Log Set heating a large area, highlighting its 33,000 BTU output and ventless design.

Image 6: Efficient heating for large areas.

5.4 Shutting Down

To turn off the appliance, rotate the control knob to the 'OFF' position. For extended periods of non-use, it is recommended to turn off the main gas supply valve.

6. Maintenance

Regular maintenance ensures optimal performance and safety. Always turn off the appliance and allow it to cool completely before performing any maintenance.

6.1 Cleaning

  • Logs: Gently brush the ceramic logs with a soft brush to remove dust or soot. Do not use abrasive cleaners.
  • Burner/Pilot: Keep the burner ports and pilot assembly clean. Use a vacuum cleaner with a soft brush attachment to remove any lint or debris.
  • Exterior: Wipe the exterior surfaces with a damp cloth.

6.2 Annual Inspection

It is recommended to have a qualified service technician inspect the appliance annually. This includes checking gas connections, burner operation, pilot assembly, and the Oxygen Depletion Sensor (O.D.S.) for proper function.

7. Troubleshooting

If you encounter issues with your gas log set, refer to the following common problems and solutions. For persistent problems, contact a qualified service technician.

ProblemPossible CauseSolution
Pilot will not lightNo gas supply; Air in gas line; Pilot orifice clogged; Faulty igniterCheck gas supply; Bleed air from line; Clean pilot orifice; Replace igniter (if faulty)
Main burner will not lightPilot not lit; Thermostat setting too low; Main burner orifice cloggedLight pilot; Adjust thermostat; Clean main burner orifice
Unit shuts off unexpectedlyOxygen Depletion Sensor (O.D.S.) activated; Pilot flame too weak; Insufficient ventilationEnsure adequate ventilation; Clean pilot assembly; Contact service technician if O.D.S. repeatedly activates
Unusual odorsNew unit burn-off; Gas leakInitial odors are normal; If gas odor persists, turn off gas supply and call gas company immediately

8. Specifications

FeatureDetail
Model NameDLS-N24T-2
BrandDuluth Forge
Fuel TypeNatural Gas
Heat Output33,000 BTU
Heating CoverageUp to 1,300 sq ft
Ventilation TypeVent Free
Log MaterialCeramic Fiber
Ignition TypeBattery Assisted Piezo (1 AAA battery included)
Control TypeThermostat Control
Product Dimensions24"D x 12"W x 11"H
Item Weight50 Pounds
Safety FeaturesOxygen Depletion Sensor (O.D.S.), Automatic Shut-off
CertificationsANSI Certified System, PFS Approved

9. Warranty & Support

9.1 Limited Warranty

This Duluth Forge gas log set comes with a limited warranty. Please refer to the warranty card included in your hardware pack for specific terms, conditions, and duration. Note that the warranty may be voided if the product is not installed by a qualified professional.

9.2 Customer Support

For technical assistance, replacement parts, or warranty claims, please contact Duluth Forge customer service. Contact information can be found on the product packaging or the official Duluth Forge website.

10. Official Product Videos

Duluth Forge Ventless Gas Logs, Stacked 2022

This video showcases the Duluth Forge Ventless Gas Logs in a stacked configuration, highlighting their realistic appearance and flame patterns. It provides a visual demonstration of the product's aesthetic appeal.

Duluth Forge Ventless Dual Fuel Gas Log Set - 30 in. Berkshire Split Oak - Remote Control

This video demonstrates the Duluth Forge Ventless Dual Fuel Gas Log Set, featuring a Berkshire Split Oak design and remote control functionality. While a different size and fuel option, it illustrates the general operation and visual quality of Duluth Forge ventless gas logs.

Related Documents - DLS-N24T-2

PreviewDuluth Forge Vented Natural Gas Log Installation Instructions
Comprehensive installation guide for Duluth Forge vented natural gas log sets, models FNL18L103B, FN24L103B, and FN30L103B. Covers safety, log placement, operation, curing, and parts. Approved to ANSI Z21.11.2 and Z21.60 standards.
PreviewDuluth Forge FDLR24/30-1 Dual Fuel Vent-Free Gas Log Chassis Owner's Operation and Installation Manual
This comprehensive manual provides detailed instructions for the operation and installation of the Duluth Forge FDLR24/30-1 Dual Fuel Vent-Free Gas Log Chassis. It covers safety precautions, specifications, installation procedures, operating instructions, troubleshooting, parts replacement, and warranty information.
PreviewDuluth Forge Vented Natural Gas Logs: Installation, Operation, and Safety Manual
Comprehensive guide for Duluth Forge Vented Natural Gas Logs (Models FNVL18-1, FNVL24-1, FNVL30-1). Includes installation instructions, operating procedures, safety warnings, maintenance tips, troubleshooting, parts lists, and warranty information.
PreviewDuluth Forge FVFLC22-1 Vent-Free Gas Logs Installation Instructions
Installation instructions for the Duluth Forge FVFLC22-1 Vent-Free Gas Logs Log Cluster, including safety guidelines, proper log placement, and operational advice. Compatible with FLM24-1-LP, FLM24-1-NG, FLT24-1-LP, FLT24-1-NG, and FDLT24-1 Burner Chassis.
PreviewDuluth Forge FDLR24/30-1 Vent-Free Gas Log Chassis Owner's Operation and Installation Manual
Comprehensive guide for the Duluth Forge FDLR24/30-1 Vent-Free Gas Log Chassis, covering installation, operation, safety, maintenance, and troubleshooting for natural and propane gas. Includes detailed instructions and warnings.
PreviewDuluth Forge FDLR18-1 Vent-Free Gas Log Chassis Owner's Operation and Installation Manual
Comprehensive guide for the Duluth Forge FDLR18-1 Vent-Free Gas Log Chassis, covering safety, specifications, installation, operation, maintenance, and troubleshooting.