1. Product Overview
The GROWNEER 6-inch inline exhaust fan with filter is designed to provide efficient air purification and ventilation for various residential applications. This system offers dual operational modes and advanced filtration to improve indoor air quality.
- Dual-Mode Ventilation & Purification: Operates in Air Purification Mode (210 CFM) with a HEPA filter for air circulation and cleaning, or Powerful Exhaust Mode (340 CFM) without the filter for rapid odor and moisture removal.
- 3-Stage Advanced Filtration: Features a Pre-filter, Activated Carbon filter, and MERV 12 HEPA Filter to capture up to 99.97% of dust, pollen, lint, smoke, and eliminate odors and formaldehyde.
- Versatile Applications: Suitable for whole-house ventilation, spot ventilation in bathrooms and kitchens, air purification in grow tents, workshops, and basements.
- Remote Control: Includes a wall-mounted touch remote control panel for convenient operation and fan speed adjustment.

Figure 1: GROWNEER 6-Inch Inline Exhaust Fan with Filter. This image shows the main unit with its dual intake ports and exhaust port.
2. Safety Information
WARNING: To reduce the risk of serious injury or property damage, observe the following safety precautions:
- Installation must be completed by qualified personnel in accordance with all applicable local and national electrical codes and standards.
- Ensure the ceiling or joist can bear a static load at least two times the weight of the product.
- Exercise caution to avoid damaging electrical wiring or other hidden utilities when cutting or drilling into walls or ceilings.
- Do not place the fan where it can be reached from a bathtub or shower.
- Unless the fan is part of a major circuit, it must be grounded to prevent electrical hazards.
- This product is intended for indoor use only.
3. Package Contents
Verify that all components are present before beginning installation:
- Inline Exhaust Fan Unit
- Adjustable Mounting Frame
- Wall-Mounted Touch Remote Control Panel
- HEPA Filter (pre-installed or separate)
- Pre-filter and Activated Carbon Filter
- Wire Rope Hoisting Hardware
- Mounting Screws and Anchors
- Instruction Manual

Figure 2: Illustrated view of all items included in the product package.
4. Setup and Installation
The GROWNEER inline exhaust fan offers three primary installation methods. Choose the method best suited for your application.
4.1 Electrical Connection
Before any installation, ensure the power supply is disconnected. Connect the N/L/E wires from the fan to their corresponding colored wires in your electrical system (Neutral, Live, Earth/Ground).
Video 1: Installation Guide for GROWNEER 6-Inch Inline Exhaust Fan. This video demonstrates the steps for installing the filter, connecting electrical wires, and performing the wire rope hoisting and frame installations.
4.2 Filter Installation (if not pre-installed)
- Unscrew the filter access panel on the fan unit.
- Carefully unwrap the HEPA filter and the pre-filter/activated carbon filter.
- Insert the filters into the designated slots, ensuring proper orientation.
- Secure the filter access panel by screwing it back into place.

Figure 3: Components of the 3-stage filtration system, including the pre-filter, activated carbon filter, and MERV 12 HEPA filter.
4.3 Mounting Options
Refer to the diagram below for visual guidance on each installation method.

Figure 4: Diagram illustrating the three installation methods: Bar Mount, Ceiling Mount (Wire Rope Hoisting), and Direct Beam Mount.
4.3.1 Wire Rope Hoisting (Ceiling Mount)
- Attach the mounting brackets to the fan unit using the provided screws.
- Secure the adjustable load-bearing wires to the ceiling structure.
- Pass the wires through the mounting brackets on the fan unit.
- Adjust the wire length to suspend the fan at the desired height and level.
4.3.2 Adjustable Frame Mount
- Assemble the adjustable frame to fit the desired space (e.g., between joists or within a cabinet). The frame is extendable from 11.41" to 22".
- Secure the frame to the mounting surface using appropriate screws.
- Place the fan unit within the frame and secure it using the provided hardware.
4.3.3 Direct Beam Mount
- Position the fan unit directly against a sturdy beam or flat surface.
- Secure the fan unit to the beam using appropriate screws through the designated mounting points.
Note: Ducts and grilles are not included and must be purchased separately for a complete ventilation system.
5. Operating Instructions
The fan is controlled via the included wall-mounted touch remote control panel.

Figure 5: The wall-mounted touch remote control panel for operating the fan.
- Power On/Off: Press the power button on the remote to turn the unit on or off.
- Mode Selection: The fan supports two modes:
- Air Purification Mode (210 CFM): Engages the 3-stage filtration system for air cleaning.
- Powerful Exhaust Mode (340 CFM): Operates without the filter for maximum airflow and odor/moisture removal.
- Fan Speed Adjustment: The remote control allows for 5-speed adjustment of the fan. Use the '+' and '-' buttons to increase or decrease the fan speed.
6. Maintenance
Regular maintenance ensures optimal performance and longevity of your GROWNEER inline exhaust fan.
- Filter Replacement: The downward-facing filter door allows for easy access. Replace the HEPA and activated carbon filters periodically based on usage and air quality. Refer to the filter manufacturer's recommendations for replacement intervals.
- Cleaning: Periodically clean the exterior of the fan unit with a soft, damp cloth. Ensure the unit is powered off and unplugged before cleaning. Do not use abrasive cleaners or solvents.
- Ductwork Inspection: Inspect connected ductwork for any blockages, leaks, or damage that could impede airflow.
7. Troubleshooting
If you encounter issues with your GROWNEER inline exhaust fan, refer to the following common troubleshooting steps:
| Problem | Possible Cause | Solution |
|---|---|---|
| Fan does not turn on | No power supply; loose wiring; remote control battery low. | Check power connection and circuit breaker. Verify wiring connections. Replace remote control batteries. |
| Reduced airflow | Clogged filters; blocked ductwork; incorrect mode selection. | Inspect and replace filters if necessary. Check ductwork for obstructions. Ensure fan is in the desired operating mode. |
| Unusual noise or vibration | Loose mounting; foreign object in fan; motor issue. | Ensure the fan is securely mounted. Power off and inspect for foreign objects. If noise persists, contact customer support. |
| Remote control not responding | Battery low or dead; signal interference; remote out of range. | Replace remote batteries. Reduce interference sources. Ensure remote is within effective range (up to 15m, may vary through walls/ceilings). |
8. Specifications
| Brand | GROWNEER |
| Model Name | Inline Filter Box (AX253702001) |
| Air Flow Capacity (without filter) | 340 Cubic Feet Per Minute (CFM) |
| Air Flow Capacity (with filter) | 210 Cubic Feet Per Minute (CFM) |
| Noise Level | 50 Decibels (dB) |
| Voltage | 120 Volts (AC) |
| Power Source | AC |
| Product Dimensions | 16"D x 12.8"W x 9.8"H |
| Item Weight | 19.96 pounds |
| Special Features | Quiet Operation, Remote Controlled |
| Room Type | Attic, Bathroom, Garage, Living Room, Study Room |
| Installation Type | Wire Rope Hoisting, Adjustable Frame Mount, Direct Beam Mount |
| Indoor/Outdoor Usage | Indoor |
9. Warranty and Support
For warranty information or technical support, please contact GROWNEER customer service. Keep your purchase receipt as proof of purchase.
Contact Information: Refer to the product packaging or the official GROWNEER website for the most current contact details.