1. Introduction

The ORIA Digital Fridge Thermometer is designed to monitor temperatures in refrigerators, freezers, and indoor environments. It features a main display unit and two wireless sensors, providing real-time temperature and humidity readings, along with alarm functions for temperature deviations.

ORIA Digital Fridge Thermometer main unit and two wireless sensors

Image: The main display unit and two wireless sensors (labeled 1 and 2) of the ORIA Digital Fridge Thermometer.

2. Package Contents

  • 1 x Main Display Unit
  • 2 x Wireless Sensors
  • 1 x USB Cable (for main unit power)
  • 1 x User Manual

Note: AAA batteries are required for operation and are not included in the package. The main unit requires 2 AAA batteries or USB power. Each sensor requires 2 AAA batteries.

3. Product Overview

Main Display Unit

The main unit features a 3.42-inch color screen displaying temperatures from both wireless sensors (CH1, CH2) and the indoor temperature/humidity. It includes buttons for settings and a touch-sensitive area for backlight control and unit switching.

Rear view of ORIA Digital Fridge Thermometer main unit showing buttons, hang hole, magnet, power port, stand, and battery compartment

Image: Rear view of the main display unit, highlighting the CH1, CH2, +/MEM, and /RF buttons, along with the hang hole, magnet, USB power port, stand, and battery compartment.

Wireless Sensors

Two independent wireless sensors are included to monitor temperatures in separate locations, such as a refrigerator and a freezer. Each sensor is compact and battery-powered.

Dimensions of ORIA Digital Fridge Thermometer main unit and wireless sensor, with icons for key features

Image: Illustrates the dimensions of the main unit (8.2cm x 8.2cm) and a wireless sensor (5.2cm x 7.5cm). Icons indicate features like Easy to Set, Dual-Channel, MAX/MIN Record, Temperature Alarm, Backlight, and Dual Power Supply.

4. Setup

4.1 Battery Installation

  1. Main Display Unit: Open the battery compartment on the back. Insert 2 AAA batteries, observing polarity. Alternatively, connect the main unit using the provided USB cable for continuous power and backlight.
  2. Wireless Sensors: Open the battery compartment on each sensor. Insert 2 AAA batteries into each sensor, observing polarity.

4.2 Pairing Sensors

The main unit and sensors should automatically pair upon battery installation. If pairing does not occur or is lost:

  • Ensure both the main unit and sensors have fresh batteries.
  • Place the sensors close to the main unit.
  • On the main unit, long press the /RF button to initiate re-pairing. The screen will display the alarm symbol. Press again to clear previous connection data and re-scan.

5. Operating Instructions

5.1 Button Functions (Rear of Main Unit)

  • CH1 Button:
    • Short press: Toggle CH1 alarm ON/OFF. An alarm symbol appears when active.
    • Long press: Set CH1 alarm temperature (maximum and minimum values). Use +/- buttons to adjust. Configurable range: -40°C to 60°C (-40°F to 140°F).
  • CH2 Button:
    • Short press: Toggle CH2 alarm ON/OFF. An alarm symbol appears when active.
    • Long press: Set CH2 alarm temperature (maximum and minimum values). Use +/- buttons to adjust. Configurable range: -40°C to 60°C (-40°F to 140°F).
  • +/MEM Button:
    • Short press: Switch between 24H and ALL TIME logging modes to display highest and lowest recorded values.
    • Long press: Clear the history protocol for the currently displayed mode.
  • /RF Button:
    • Short press: Display the set alarm values for both channels (alarm symbol appears). Default values are 60°C (max) and -40°C (min).
    • Long press: Re-pair the screen with sensors. Press again to remove previous connector data and initiate a new scan.

5.2 Light/°C/°F Button (Top Touch Area)

Hand touching the top of the ORIA Digital Fridge Thermometer to activate backlight and switch temperature units

Image: A hand interacting with the top touch area of the main unit, demonstrating backlight activation and temperature unit switching.

  • Backlight:
    • Battery mode: Short press to turn on the backlight for 8 seconds (automatic shutdown to save energy).
    • USB mode: Short press to toggle the backlight ON/OFF. When ON, it stays illuminated.
  • Temperature Unit (°C/°F): Long press for 2 seconds to switch between Celsius (°C) and Fahrenheit (°F).

5.3 Alarm Function

When the temperature measured by a sensor exceeds the set maximum or falls below the set minimum, the device will trigger a continuous audible alarm and the backlight will flash red. This provides an immediate warning to protect stored items.

ORIA Digital Fridge Thermometer display showing normal temperature readings and a red alarm display

Image: Comparison of the normal display and the alarm display, which shows a red backlight and an alarm bell icon when a temperature threshold is exceeded.

6. Features

  • Dual Channel Monitoring: Equipped with two independent wireless sensors to simultaneously monitor temperatures in two separate locations (e.g., fridge and freezer).
  • Clear Color Display: A 3.42-inch color screen with white backlight ensures easy readability of all data, even in low light conditions.
  • Adjustable Temperature Alarm: Set custom high and low temperature alarms for each sensor. An audible alarm and flashing red backlight activate if temperatures exceed or fall below these thresholds.
  • Max/Min Temperature and Humidity Records: Displays the highest and lowest recorded temperatures and humidity for the last 24 hours or since the last reset.
  • Indoor Monitoring: The main unit also monitors the ambient indoor temperature (-10°C to 60°C / -14.2°F to 140°F) and humidity (10% to 99% RH) where it is placed.
  • Wide Outdoor Temperature Range: Wireless sensors monitor temperatures from -40°C to 60°C (-40°F to 140°F).
  • Stable Wireless Transmission: Provides a stable wireless range of up to 100 meters (328 feet) in open areas.
  • Dual Power Supply: The main unit can be powered by 2 AAA batteries or a USB cable. Sensors are powered by 2 AAA batteries each.
  • Low Battery Warning: Indicates when batteries are running low.

7. Placement and Installation

Main Display Unit

The main unit offers multiple placement options:

  • Stand: Use the integrated foldable stand for tabletop placement.
  • Wall Mount: Utilize the hang hole on the back to mount it on a wall.
  • Magnetic Attachment: The magnetic back allows attachment to metallic surfaces, such as a refrigerator door.

Wireless Sensors

Place the wireless sensors in the desired monitoring locations, such as inside a refrigerator or freezer. Ensure they are positioned to avoid direct contact with food or ice, which could affect readings. The sensors also have a hang hole for wall mounting.

Wireless sensor placed inside a refrigerator, showing wireless transmission

Image: A wireless sensor placed inside a refrigerator, illustrating its remote monitoring capability. The main unit is shown outside the fridge.

8. Specifications

ParameterValue
Main Unit Dimensions8.1 x 2 x 8.1 cm (approx. 3.2 x 0.8 x 3.2 inches)
Sensor Dimensions5 x 2 x 7.5 cm (approx. 2 x 0.8 x 3 inches)
Main Unit Weight93g
Sensor Weight33g
Indoor Temperature Range-10°C to 60°C (14.2°F to 140°F)
Outdoor Temperature Range (Sensors)-40°C to 60°C (-40°F to 140°F)
Indoor Humidity Range10% to 99% RH
Temperature Accuracy±1°C (±2°F)
Humidity Accuracy±5% RH
Wireless Transmission RangeUp to 100 meters (328 feet) in open areas
Main Unit Power Supply2 x AAA batteries (not included) or USB cable
Sensor Power Supply2 x AAA batteries per sensor (not included)
Display TypeLCD color screen
MaterialPlastic
Model Numberdda2bea4-fae9-4009-aea9-abf190ec66fb

9. Troubleshooting

  • No Display/Low Battery: Check battery installation and replace with fresh AAA batteries. If using USB power for the main unit, ensure the cable is securely connected.
  • Sensors Not Connecting: Ensure sensors are within range (up to 100m in open areas, less with obstructions). Re-pair by long pressing the /RF button on the main unit.
  • Inaccurate Readings: Ensure sensors are not in direct contact with cold surfaces or food, which can affect readings. Allow time for temperatures to stabilize after placement.
  • Alarm Not Functioning: Verify that the alarm is enabled for the respective channel (CH1/CH2) and that the alarm thresholds are set correctly.
  • Backlight Issues: In battery mode, the backlight turns off after 8 seconds to save power. For continuous backlight, use USB power.

10. Warranty and Support

ORIA provides a 1-year warranty for this product, allowing for replacement within 365 days of purchase. Additionally, lifetime after-sales service is available for all customers. For support or warranty claims, please contact ORIA customer service through your purchase platform.

Related Documents - dda2bea4-fae9-4009-aea9-abf190ec66fb

PreviewORIA WA28 2-Channel Refrigerator Thermometer User Manual | Installation, Operation, Troubleshooting
Comprehensive user manual for the ORIA WA28 2-Channel Refrigerator Thermometer. Learn how to install, operate, and troubleshoot your wireless thermometer for accurate indoor and outdoor temperature monitoring.
PreviewORIA Analog Alarm Clock: Usage Method and Important Precautions
Detailed instructions on how to use the ORIA analog alarm clock, including battery installation, time setting, and important matters to pay attention to for safe and optimal operation.
PreviewEAE KNX Oria Switch Series Installation Manual
Installation guide for the EAE KNX Oria Switch Series, detailing operation, installation, technical specifications, and commissioning for smart home automation systems.
PreviewSimplex 4009 IDNet NAC Extender Installation and Operation Guide
Comprehensive guide for installing and configuring the Simplex 4009 IDNet Notification Appliance Circuit (NAC) Extender. Covers hardware components, system configuration, wiring, and operational modes for fire alarm systems.