1. Introduction
This manual provides detailed instructions for the safe and effective use of your FeelTech TR120 Infrared Thermal Imaging Camera. Please read this manual thoroughly before operating the device and retain it for future reference. The TR120 is designed for various applications including electrical device repair, HVAC inspection, and general thermal analysis.
2. Product Overview
The FeelTech TR120 is a handheld infrared thermal imager featuring a 120x90 infrared resolution, a wide temperature measurement range of -20°C to 400°C, and a 3.5-inch color LCD display. It includes a visible light camera for dual-mode imaging, automatic hot/cold spot tracking, and a powerful LED light for dark environments.

Figure 2.1: Front and back view of the FeelTech TR120 Infrared Thermal Imaging Camera. The front features the display screen and control buttons, while the back shows the thermal and visible light lenses, along with the powerful LED light.

Figure 2.2: Detailed view of the TR120's top section, highlighting the magnetic dust cap protecting the lenses, the visible light camera, and the powerful LED light for illumination in low-light conditions.
3. Setup
3.1 Unboxing and Contents
Carefully unpack all items from the product packaging. Verify that all components are present.

Figure 3.1: The complete package contents for the FeelTech TR120, including the thermal imager, a protective carrying case, a wrist strap, a USB charging/data cable, and the user manual.
The box should contain:
- FeelTech TR120 Infrared Thermal Imaging Camera
- USB Type-C Cable
- User Manual
- Carrying Case
- Wrist Strap
3.2 Charging the Battery
The TR120 is equipped with a 2600mAh rechargeable battery. Before first use, fully charge the device.
- Connect the provided USB Type-C cable to the camera's USB port.
- Connect the other end of the USB cable to a standard USB power adapter (not included) or a computer's USB port.
- The charging indicator on the device will show the charging status. A full charge typically takes several hours.
3.3 Powering On/Off
- To Power On: Press and hold the power button (usually marked with a power symbol) until the display screen illuminates.
- To Power Off: Press and hold the power button until the device powers down.
4. Operating Instructions
4.1 Basic Controls and Display
Familiarize yourself with the buttons and the information displayed on the 3.5-inch LCD screen. The screen typically shows the thermal image, temperature readings (max, min, center spot), battery status, and selected palette.
4.2 Temperature Measurement
Point the camera at the object or area you wish to measure. The device will automatically display the temperature distribution. The TR120 features automatic tracking and warning for high and low temperatures within its -20°C to 400°C range.
4.3 Color Palettes
The TR120 offers 6 different color palettes to visualize thermal images. These palettes help in distinguishing temperature differences more clearly depending on the application and user preference.

Figure 4.1: The TR120 display showcasing six distinct color palettes: High Resolution Rainbow, Hot Red, Lava, Rainbow, Iron Oxide Red, and White Heat. Each palette offers a different visual representation of temperature gradients, enhancing clarity for various inspection tasks.
To change the color palette, navigate through the menu options using the device's buttons until you find the palette selection. Choose the palette that best suits your viewing needs.
4.4 Dual Camera Mode (Infrared & Visible Light)
The TR120 integrates both an infrared thermal imager and a visible light camera. This allows for a blended image display, combining the thermal data with visual details for better context and identification of heat sources.

Figure 4.2: The TR120's capability to display both infrared light imaging (top) and visible light imaging (bottom). This dual-mode functionality allows users to overlay thermal data onto a real-world visual, providing enhanced context for inspections.
Access this mode through the device's menu to switch between pure infrared, visible light, or a blended image.
4.5 Hot/Cold Spot Tracking
The device automatically identifies and tracks the hottest and coldest points within the field of view, displaying their temperatures on the screen. This feature is crucial for quickly identifying anomalies.
4.6 Using the Powerful LED Light
For inspections in dimly lit or dark areas, activate the built-in powerful LED light. This ensures safe operation and provides necessary illumination for the visible light camera.
4.7 USB Communication and PC Analysis Software
Connect the TR120 to a computer using the USB Type-C cable to transfer captured images and data. The device supports PC analysis software (available separately or via manufacturer's website) for in-depth thermal image analysis and reporting.
4.8 Typical Applications
The TR120 is suitable for a variety of professional and DIY applications:

Figure 4.3: Visual examples of the FeelTech TR120 in use across various applications, including motor detection, distribution cabinet testing, circuit board inspection, HVAC system inspection, automotive repair, and its compatibility with tripod support for stable measurements.
- Motor Detection: Identifying overheating components in motors.
- Distribution Cabinet Test: Checking for loose connections or overloaded circuits in electrical panels.
- Circuit Board Inspection: Pinpointing hot spots on electronic circuit boards.
- HVAC Inspection: Detecting air leaks, insulation issues, or blockages in heating, ventilation, and air conditioning systems.
- Auto Repair: Diagnosing automotive issues such as brake problems, exhaust leaks, or engine overheating.
5. Maintenance
5.1 Cleaning
- Device Body: Use a soft, damp cloth to wipe the exterior of the camera. Do not use abrasive cleaners or solvents.
- Lenses: Gently clean the thermal and visible light lenses with a lens cleaning cloth or a soft, lint-free cloth. Avoid touching the lenses with bare hands.
5.2 Storage
When not in use, store the TR120 in its protective carrying case in a cool, dry place, away from direct sunlight and extreme temperatures. Ensure the magnetic dust cap is in place to protect the lenses.
5.3 Battery Care
To prolong battery life, avoid fully discharging the battery frequently. If storing the device for an extended period, charge the battery to approximately 50% and recharge every few months.
6. Troubleshooting
If you encounter issues with your FeelTech TR120, refer to the following common problems and solutions:
- Device does not power on:
- Ensure the battery is sufficiently charged. Connect the device to a power source and try again.
- Verify that the power button is pressed and held correctly.
- Inaccurate temperature readings:
- Ensure the lenses are clean and free from obstructions.
- Check the emissivity setting if adjustable (refer to advanced settings in the device menu). Different materials have different emissivities.
- Ensure the measurement distance is appropriate for the target size.
- Display is blank or frozen:
- Try restarting the device by holding the power button.
- If the issue persists, contact customer support.
- Cannot connect to PC via USB:
- Ensure the USB cable is securely connected to both the camera and the computer.
- Try a different USB port or cable.
- Check if necessary drivers are installed on your computer (if required by the analysis software).
7. Specifications
The following table outlines the key technical specifications for the FeelTech TR120 Infrared Thermal Imaging Camera:

Figure 7.1: A comparison table detailing specifications for various thermal imager models, with the FeelTech TR120's specifications clearly visible in the middle column.
| Feature | Specification |
|---|---|
| Model Number | EC-Mileseey-TR120 |
| Infrared Resolution | 120 x 90 pixels |
| Display Size | 3.5 inch |
| Display Mode | Thermal image, Visible image, MSX blending image |
| Temperature Range | -20°C to 400°C |
| Thermal Sensitivity | <60mK |
| Spectral Response Band | 8-14µm |
| Pixel Size | 17µm |
| Frame Rate | <25Hz |
| Color Palettes | 6 (High Resolution Rainbow, Hot Red, Lava, Rainbow, Iron Oxide Red, White Heat) |
| High and Low Temperature Alarm | Yes |
| Battery | 2600mAh (or 5000mAh as per image) Lithium-ion 3.7V rechargeable battery |
| Communication Interface | Type-C USB |
| LED Lighting | High power white LED |
| IP Level | IP 65 |
| Working Temperature | -10°C to 50°C |
| Storage Temperature | -20°C to 60°C (or -40°C to 70°C as per image) |
| Fall Prevention | 1.5m |
| Dimensions | 238*95.5*85.5mm |
| Weight | 540g (1 Kilogram as per product specifications) |
| Specification Met | CE, RoHS |
| Manufacturer | Shenzhen Mileseey TECHNOLOGY CO., LTD |
| Date First Available | July 3, 2025 |
Note: Some specifications, such as battery capacity, storage temperature, and weight, may vary slightly between product listings and the comparison chart. Please refer to the product packaging for the most accurate information.
8. Warranty and Support
The FeelTech TR120 Infrared Thermal Imaging Camera is manufactured under strict quality control standards. For information regarding warranty coverage, terms, and conditions, please refer to the warranty card included with your product or contact the seller directly. EU spare part availability duration is 1 year.
For technical support, troubleshooting assistance beyond this manual, or service inquiries, please contact your point of purchase or the manufacturer's authorized service center. Keep your purchase receipt as proof of purchase for warranty claims.