Getdoublerich 1B10U30N92OGHSG2SGLM2AZ

Contents

Electronic Industrial Alarm Buzzer

Model: 1B10U30N92OGHSG2SGLM2AZ | Brand: Getdoublerich

1. Introduction

This manual provides comprehensive instructions for the installation, operation, and maintenance of the Getdoublerich Electronic Industrial Alarm Buzzer. Designed for industrial use, this buzzer produces a continuous sound at a high decibel level, making it suitable for various warning and signaling applications. Please read this manual thoroughly before installation and use to ensure proper function and safety.

2. Safety Information

Always observe the following safety precautions to prevent injury or damage to the device:

  • Ensure the power supply voltage matches the rated voltage of the buzzer (DC 3-24V).
  • Do not expose the device to extreme temperatures or moisture beyond its specified operating range.
  • Handle wiring with care. Ensure correct polarity (red wire typically positive, black wire negative) to avoid damage.
  • Installation should be performed by qualified personnel if complex wiring or integration into existing systems is required.
  • Keep the device away from flammable materials.

3. Product Overview

The Getdoublerich Electronic Industrial Alarm Buzzer is a compact and robust signaling device. Key features include:

  • Loud Continuous Sound: Produces a clear and evident alarm with a sound pressure of 100 dB.
  • Wide Voltage Range: Operates on DC 3-24V, offering versatility for various industrial applications.
  • Convenient Wiring: Features a simple 2-wire design (black and red) for easy connection.
  • Durable Construction: Made from high-quality plastic material for long-term use in industrial environments.
  • Compact Design: Small overall dimensions (48 x 30 x 15 mm) allow for easy mounting in diverse settings.
Front view of the electronic industrial alarm buzzer with black and red wires.
Figure 3.1: Front view of the buzzer, showing the sound outlet and wiring.

This image displays the main body of the electronic buzzer, highlighting its compact black plastic casing and the attached red and black power wires. The top surface features a circular grille for sound emission.

Bottom view of the electronic industrial alarm buzzer showing mounting holes and voltage label.
Figure 3.2: Bottom view of the buzzer with voltage specifications.

This image shows the underside of the buzzer, revealing the mounting tabs with pre-drilled holes and a label indicating the DC 3-24V operating voltage range.

Electronic industrial alarm buzzer integrated into a vehicle dashboard for demonstration.
Figure 3.3: Example application of the buzzer in a vehicle.

This image illustrates a potential application of the buzzer, shown in the foreground with a vehicle dashboard in the background, suggesting its use in automotive or similar industrial settings for alerts.

4. Specifications

Parameter Value
Product Name Electronic Buzzer
Sound Type Continuous Sound
Rated Voltage DC 3 – 24 V
Rated Current 15mA
Sound Pressure 100 dB
Operating Temperature -20 °C to +45 °C
Overall Dimensions (L x W x H) 48 x 30 x 15 mm
Mounting Holes (L x W) 3.5 x 4 mm (0.14 x 0.16 inches)
Mounting Hole Distance 40 mm
Cable Length 11 cm
External Material Plastic
Color Black
Weight 8 g

5. Setup and Installation

Follow these steps for proper installation of the electronic buzzer:

  1. Choose a Mounting Location: Select a stable surface where the buzzer can be securely mounted. Consider proximity to the power source and the desired audibility of the alarm.
  2. Prepare Mounting Surface: Mark the positions for the mounting holes based on the buzzer's dimensions (40 mm distance between holes). Drill pilot holes if necessary.
  3. Secure the Buzzer: Use appropriate screws or fasteners (not included) to attach the buzzer to the chosen surface through its mounting tabs.
  4. Wiring Connection:
    • Identify the red wire as the positive (+) terminal and the black wire as the negative (-) terminal.
    • Connect the red wire to the positive (+) terminal of your DC power source (3-24V).
    • Connect the black wire to the negative (-) terminal of your DC power source.
    • Ensure all connections are secure and insulated to prevent short circuits.
  5. Test Functionality: Once wired, apply power to the circuit to verify the buzzer emits a continuous sound.
Top-down view of the electronic industrial alarm buzzer showing mounting holes and wires.
Figure 5.1: Buzzer with visible mounting points.

This image provides a clear view of the buzzer from above, emphasizing the two mounting holes on its base, which are crucial for secure installation.

Close-up of the red and black wires of the electronic industrial alarm buzzer.
Figure 5.2: Detail of the wiring.

A close-up shot of the red and black wires, showing their stripped ends ready for connection to a power source. This highlights the simplicity of the wiring process.

6. Operating Instructions

The Getdoublerich Electronic Industrial Alarm Buzzer is designed for straightforward operation:

  • The buzzer will emit a continuous sound when a DC voltage between 3V and 24V is applied to its red (positive) and black (negative) wires.
  • The sound will cease when the power supply is disconnected.
  • Integrate the buzzer into your control system (e.g., with a switch, sensor, or relay) to activate it under specific conditions, such as an alarm trigger or status indication.

7. Maintenance

The electronic buzzer requires minimal maintenance:

  • Cleaning: Periodically wipe the exterior of the buzzer with a soft, dry cloth to remove dust and debris. Do not use abrasive cleaners or solvents.
  • Inspection: Regularly check the wiring connections for any signs of wear, corrosion, or loose contacts. Ensure the mounting is still secure.
  • Environmental Conditions: Ensure the buzzer remains within its specified operating temperature range (-20 °C to +45 °C) and is protected from excessive moisture or direct water exposure.

8. Troubleshooting

If the buzzer is not functioning as expected, consider the following:

Problem Possible Cause Solution
Buzzer does not sound.
  • No power supply.
  • Incorrect voltage (outside 3-24V DC).
  • Incorrect wiring polarity.
  • Loose or faulty connections.
  • Damaged buzzer.
  • Verify power is supplied to the circuit.
  • Check power supply voltage is within 3-24V DC.
  • Ensure red wire is connected to positive, black to negative.
  • Inspect and secure all wire connections.
  • If all else fails, the buzzer may be faulty and require replacement.
Sound is weak or intermittent.
  • Insufficient voltage.
  • Partial short circuit.
  • Obstruction of sound outlet.
  • Ensure voltage is stable and within the optimal range (e.g., closer to 24V for maximum loudness).
  • Check for any unintended contact between wires or components.
  • Clear any debris or obstructions from the buzzer's sound outlet.

9. Warranty and Support

For warranty information or technical support, please refer to the seller's policy or contact Getdoublerich directly through their official channels. You can visit the Getdoublerich Store on Amazon for more information.

© 2025 Getdoublerich. All rights reserved.

This manual is subject to change without notice.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Rate this product if you’ve used it

Was this page helpful?