BAOSHISHAN T2

BAOSHISHAN 45L Mini Aquarium Cooler and Heater with Integrated Pump (Model T2)

Instruction Manual

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of your BAOSHISHAN T2 45L Mini Aquarium Cooler and Heater. This device is designed to maintain a stable water temperature in your aquarium, ensuring a healthy environment for aquatic life. It features precise temperature control, low noise operation, and an integrated water pump for convenience.

2. Important Safety Information

3. Package Contents

Please check the package carefully to ensure all items are present:

Image showing all components included in the BAOSHISHAN T2 package: Chiller unit, power cord, silicone hose, pipe bracket, water inlet filter, flat spout for water outlet, fuse, filter cotton cover, and tool bag.

Figure 3.1: Included Components

4. Product Specifications

Image showing the product dimensions and technical specifications of the BAOSHISHAN T2 chiller, including port labels.

Figure 4.1: Product Dimensions and Ports

Technical Data
FeatureSpecification
Model NumberT2
Dimensions (L x W x H)15 x 19 x 18 cm
Weight3.7 kg
Cooling Capacity (Variable Frequency)10-93W
Heating Capacity (Variable Frequency)10-230W
Main Pump Power10.8W
Auxiliary Pump Power3.6W
Water Flow Rate50-200 L/H
Suction/Lift4m
Pipe Diameter8/11 mm
Power Cord LengthApproximately 1.6m
Temperature Control Range10 to 35 °C
Cooling Performance (Ambient 32°C)≤35L to 23-26°C; ≤45L to 25-28°C
Heating Performance (Ambient 8°C)≤45L to 28-32°C
Noise Level (Thermostat Mode)35 dB (below 40 dB in silent mode)
Suitable forFreshwater aquariums (up to 45L)

5. Setup and Installation

Follow these steps to set up your aquarium chiller:

  1. Unpack Components: Carefully remove all items from the packaging and verify against the package contents list.
  2. Positioning: Place the chiller unit on a stable, flat surface next to your aquarium. It is recommended to position the chiller on the left side of the aquarium, ensuring sufficient space (at least 10-15 cm) on the left side for proper heat dissipation.
  3. Connect Hoses:
    • Connect the silicone hoses to the inlet and outlet ports of the chiller.
    • Attach the water inlet filter to the end of the inlet hose that will be submerged in the aquarium.
    • Attach the flat spout for water outlet to the end of the outlet hose that will return water to the aquarium.
    • Secure the hoses within the aquarium using the provided pipe bracket.
  4. Submerge Hoses: Place the inlet filter and outlet spout into the aquarium, ensuring they are fully submerged.
  5. Power Connection: Connect the power cord to the chiller unit and then plug it into a suitable power outlet.
  6. Initial Priming (Automatic): The built-in self-priming water circulation design automatically purges air and fills with water upon first power-on. One-touch operation completes this process.
Diagram illustrating the built-in automatic water pump system, showing water circulation from the aquarium through the chiller and back, with a note on low noise operation.

Figure 5.1: Automatic Water Pump and Circulation

Image showing three different aquarium setups with the chiller, emphasizing its suitability for freshwater tanks and a warning for saltwater use.

Figure 5.2: Suitable for Freshwater Aquariums (with Saltwater Warning)

Image illustrating the modular design of the chiller, highlighting easy transport and cleaning of components, along with a graph showing constant temperature mode performance versus a heating rod.

Figure 5.3: Modular Design and Temperature Stability

6. Operating Instructions

6.1. Manual Temperature Adjustment

The chiller features physical buttons for direct temperature control:

  1. To unlock the screen and adjust the temperature, simultaneously press the top two buttons.
  2. Once unlocked, press either button to adjust the desired temperature.
  3. Pressing two buttons simultaneously will also initiate automatic water absorption and air exhaust.
Image showing the top panel of the chiller with buttons and display, indicating how to adjust temperature and the meaning of blue (cooling), red (heating), and green (stopped) indicator lights.

Figure 6.1: Temperature Adjustment Buttons and Status Indicators

Indicator Lights:

6.2. Smart App Control (T2 Smart Version)

The T2 Smart Version allows for remote control and monitoring via a mobile application. Refer to the product description or scan the QR code in the manual (if provided) to download the app.

Screenshot of the mobile application interface for controlling the BAOSHISHAN T2 chiller, showing various settings like pump mode, temperature alarm, calibration, and electricity usage details.

Figure 6.2: Mobile App Interface for Chiller Control

The app provides a simple and clear user interface, allowing you to:

6.3. Noise Level

The chiller is designed for low-noise operation, featuring an integrated self-priming water circulation pump and a low-noise fan with dual ball bearings. In thermostat mode, the noise level is approximately 35 decibels, making it suitable for living rooms, bedrooms, and offices.

7. Maintenance

Regular maintenance ensures the longevity and optimal performance of your chiller.

8. Troubleshooting

If you encounter issues with your BAOSHISHAN T2 chiller, please refer to the following common problems and solutions:

ProblemPossible CauseSolution
Chiller not turning onNo power supply; Loose power connection; Blown fuse.Check power outlet; Ensure power cord is securely connected; Replace fuse (refer to package contents for spare).
Water not circulatingHoses kinked or blocked; Inlet filter clogged; Pump malfunction.Check hoses for kinks or obstructions; Clean inlet filter; Contact customer support if pump is faulty.
Temperature not stable or incorrectIncorrect temperature setting; Sensor issue; Significant ambient temperature fluctuations; Chiller capacity exceeded.Verify target temperature setting; Ensure water flow is adequate; Allow time for temperature stabilization; Ensure aquarium size is within recommended limits (up to 45L). Calibrate temperature via app if necessary.
Unusual noise during operationAir trapped in system; Unit not level; Fan obstruction.Allow automatic priming to complete; Ensure unit is on a flat surface; Check for any obstructions around the fan vents.

If the problem persists after attempting these solutions, please contact customer support.

9. Warranty and Support

9.1. Warranty Information

This product is covered by a standard warranty. For specific details regarding warranty claims, returns, or defects, please refer to the purchase platform's return policy or contact the seller directly. Generally, products can be returned within 30 days of receipt if you change your mind. For defective or damaged products, specific assistance pages are available on the purchase platform.

9.2. Customer Support

For further assistance, technical support, or inquiries not covered in this manual, please contact BAOSHISHAN customer service through the retailer where the product was purchased. Please have your model number (T2) and purchase date available when contacting support.