1. Product Overview

The LANCHEZ 1.6 HP Shallow Well Pump with Pressure Tank is a robust and efficient water transfer solution designed for various applications including garden irrigation, domestic water supply, and general water transfer. This pump features a powerful 1.6 HP motor, a maximum flow rate of 1340 GPH, and a maximum head of 150 feet. Its stainless steel construction ensures durability and corrosion resistance, while the integrated 5-gallon pressure tank prolongs its service life.

LANCHEZ 1.6 HP Shallow Well Pump with Pressure Tank showing key performance metrics: Max Flow 1340 GPH, Max Head 150 Ft, Max Suction 26 Ft.

Image 1.1: Overview of the LANCHEZ 1.6 HP Shallow Well Pump highlighting its performance capabilities.

Key Features:

  • Efficient Performance: 1.6 HP motor and durable impeller provide strong suction up to 26ft, max flow of 1340 GPH, and max head of 150ft.
  • Automatic Operation: Starts at 20psi and shuts off at 40psi, with a pressure switch and external pressure gauge for real-time monitoring.
  • Safety Features: Incorporates temperature sensing technology with automatic overload stop function to protect the motor from overheating due to water shortage.
  • Durable Construction: High-quality stainless steel casing for outstanding durability and corrosion resistance. Features a carbon ceramic mechanical seal for effective water leakage prevention.
  • Integrated Pressure Tank: Compact 5-gallon pressure tank prolongs pump service life.
Diagram showing components of the LANCHEZ Shallow Well Pump: 1.6HP Powerful Motor, 1 inch NPT Discharge, 1 inch NPT Inlet, Stainless Steel pump head, Pressure Gauge, 5 Gallon Pressure Tank, Pressure Switch, and 6.5 Ft Power Cord.

Image 1.2: Detailed view of the pump's components and features.

2. Safety Information

Read and understand all safety warnings and instructions before operating this pump. Failure to follow these instructions may result in electric shock, fire, serious injury, or property damage. Keep this manual for future reference.

General Safety Warnings:

  • Electrical Safety: Ensure the power supply matches the pump's voltage (115V/60Hz). Use a grounded outlet. Do not operate with damaged cords or plugs.
  • Water and Electrical: Never immerse the pump motor in water. Avoid operating the pump in standing water unless specifically designed for submersible use (this model is not).
  • Overload Protection: The pump is equipped with thermal overload protection. If the pump stops due to overheating, disconnect power and allow it to cool before restarting. Investigate the cause of overheating (e.g., water shortage).
  • Proper Installation: Ensure all connections are secure and leak-free. Do not run the pump dry; always prime it with water before initial use.
  • Children and Pets: Keep children and pets away from the operating pump.
  • Maintenance: Disconnect power before performing any maintenance or cleaning.

3. Setup and Installation

Proper installation is crucial for the optimal performance and longevity of your LANCHEZ shallow well pump. Follow these steps carefully.

3.1 Unpacking and Inspection

  • Carefully remove the pump from its packaging.
  • Inspect the pump for any signs of damage during shipping. If damaged, do not operate and contact customer service.
  • Ensure all components listed in the packing list are present.

3.2 Connecting Pipes

The pump features 1-inch NPT inlet and discharge ports. Ensure you use appropriate plumbing fittings and sealants (e.g., PTFE tape) for a watertight connection.

  1. Install an inlet pipe with a check valve to prevent backflow.
  2. Connect the water pipe to the water inlet of the pump.
  3. Connect the pipe to the outlet of the pump, leading to your desired application (e.g., garden hose, irrigation system).
Three images showing the steps to connect pipes to the pump: first, connecting the inlet pipe; second, adding water to the pump head; third, connecting the outlet pipe.

Image 3.1: Steps for connecting pipes and priming the pump.

3.3 Priming the Pump

Before the first use, it is essential to prime the pump by filling it with water. Running the pump dry can cause damage.

  1. Remove the priming plug (usually located on top of the pump head).
  2. Pour clean water into the pump head until it is full.
  3. Replace and securely tighten the priming plug.
Image showing water being poured into the pump head for priming, with illustrations of correct and incorrect water levels.

Image 3.2: Visual guide for priming the pump before use.

3.4 Inlet Connection Methods

The pump supports two primary inlet connection methods:

  • For Water Taps: Connect directly to a municipal water tap.
  • For Self-Priming: Place the inlet hose into a water source (e.g., well, rain barrel) for self-priming operation.
Diagram illustrating two inlet connection methods: one connected to a water tap, and another with the inlet hose submerged in a water source for self-priming.

Image 3.3: Two common methods for connecting the pump's water inlet.

Installation Video:

Video 3.1: This video provides a visual guide on how to install the LANCHEZ shallow well pump, including connecting hoses and priming the unit.

4. Operating Instructions

Once the pump is properly installed and primed, it is ready for operation.

4.1 Starting the Pump

  1. Ensure all connections are secure and there are no leaks.
  2. Plug the pump into a grounded 115V/60Hz electrical outlet.
  3. Flip the waterproof On/Off switch to the 'On' position. The pump will start automatically when pressure drops below 20psi and stop when it reaches 40psi.
  4. Monitor the external pressure gauge to observe real-time pressure.
Close-up images detailing the Automatic Booster System: Automatic Pressure Switch (Auto On < 20Psi, Auto Off > 40Psi), Pressure Gauge for real-time observation, and the 5 Gallon Pressure Tank (pre-assembled).

Image 4.1: Details of the automatic booster system and pressure gauge.

4.2 Applications

The LANCHEZ shallow well pump is versatile and suitable for:

  • Garden Watering
  • Farm Irrigation
  • Domestic Water Pressurization
  • Water Transfer (e.g., from rain barrels, pools, ponds)
Collage of images showing various applications of the pump: Garden Watering, Farm Irrigation, Domestic Water Pressurization, and Water Transfer.

Image 4.2: Examples of pump applications.

Operation Video:

Video 4.1: This video demonstrates the operation of the LANCHEZ 1.6HP Shallow Well Pump with Pressure Tank, showcasing its use in various scenarios.

5. Maintenance

Regular maintenance ensures the longevity and efficient operation of your pump. Always disconnect the power supply before performing any maintenance.

5.1 Cleaning

  • Periodically clean the exterior of the pump to prevent dirt and debris buildup.
  • Check the inlet screen (if applicable) for blockages and clean as needed to maintain optimal flow.

5.2 Winterization (for cold climates)

  • Drain all water from the pump and connected pipes to prevent freezing and damage.
  • Store the pump in a dry, frost-free location during winter months.

5.3 General Checks

  • Inspect power cords and plugs for any damage.
  • Check for any unusual noises or vibrations during operation, which may indicate a problem.
  • Ensure the pressure tank is functioning correctly and maintaining pressure.

6. Troubleshooting

This section provides solutions to common issues you might encounter with your pump. For problems not listed here, contact LANCHEZ customer service.

ProblemPossible CauseSolution
Pump does not startNo power; tripped circuit breaker; motor overload; faulty switch.Check power connection; reset breaker; allow motor to cool; inspect switch.
Pump runs but no water flowsPump not primed; air in system; clogged inlet/outlet; low water source.Prime the pump; check for air leaks; clear blockages; ensure adequate water supply.
Low pressure or flowPartial blockage; worn impeller; pressure tank issue; leaks in system.Check for blockages; inspect impeller; check pressure tank air charge; repair leaks.
Pump cycles frequentlyLeaks in plumbing; pressure tank air charge too low; faulty pressure switch.Check for leaks; recharge pressure tank; replace pressure switch.
Pump is noisyAir in pump; cavitation; loose mounting; foreign object.Bleed air; ensure adequate water supply; tighten mounting bolts; inspect for debris.

7. Specifications

Detailed technical specifications for the LANCHEZ 1.6 HP Shallow Well Pump.

Diagram showing the dimensions of the LANCHEZ Shallow Well Pump and a list of its technical specifications including Voltage, Horsepower, Tank Capacity, Max Flow Rate, Max Lift, Max Suction, Max Water Temperature, Protection, and Inlet/Outlet size.

Image 7.1: Dimensions and technical specifications of the pump.

SpecificationValue
BrandLANCHEZ
Model1.6HP Shallow Well Pump
Horsepower1.6 HP
Voltage115 Volts
Wattage1200 watts
Maximum Flow Rate1340 GPH (23 Gallons Per Minute)
Maximum Lifting Height (Head)150 Feet
Maximum Suction26 Feet
Pressure Tank Capacity5 Gallons
Product Dimensions (L x W x H)20"L x 13"W x 22"H
MaterialStainless Steel
Item Weight32.4 pounds
Power SourceCorded Electric
Included Components1.6 HP Shallow Well Pump with Pressure Tank
Warranty3 Year Manufacturer

8. Warranty and Support

LANCHEZ stands behind the quality of its products.

8.1 Manufacturer's Warranty

This product comes with a generous 3-year manufacturer's warranty. This warranty covers defects in materials and workmanship under normal use. Please retain your proof of purchase for warranty claims.

8.2 Customer Service

For professional installation and maintenance support, or any questions regarding your LANCHEZ pump, please contact our customer service team. We are committed to assisting you.

Additional protection plans may be available for purchase:

  • 3-Year Protection Plan
  • 4-Year Protection Plan
  • Complete Protect (monthly billing)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.