Important Safety Information

WARNING: Always follow all safety precautions to reduce the risk of injury or damage. Read and understand all instructions before operation.

  • Wear appropriate personal protective equipment (PPE) such as safety glasses.
  • Ensure the work area is clear of obstructions and well-lit.
  • Do not operate the pump in explosive atmospheres, such as in the presence of flammable liquids, gases, or dust.
  • Always disconnect the battery pack before making any adjustments, changing accessories, or storing the tool.
  • Do not pump flammable liquids. This pump is designed for water and water/glycol mixtures only.
  • Keep children and bystanders away while operating the pump.

Setup

1. Battery Installation

  • Ensure the pump's power switch is in the OFF position.
  • Align the 20V MAX battery pack (sold separately) with the battery port on the pump.
  • Slide the battery pack into the pump until it clicks securely into place.
  • To remove, press the battery release button and slide the battery out.
DEWALT Transfer Pump with highlighted features

Figure 2: Key features of the DEWALT Transfer Pump, including the battery compartment, LED-embedded power switch, and self-priming pump mechanism.

2. Hose Connection

  • Connect the intake hose to the inlet port of the pump. Ensure a tight, leak-free connection.
  • Connect the discharge hose to the outlet port of the pump.
  • Place the intake end of the hose into the liquid source (e.g., water tank, bucket).
  • Direct the discharge end of the hose to the desired drainage or transfer location.

Operation

1. Priming the Pump

  • The DEWALT Transfer Pump features a self-priming design. However, for optimal performance, ensure the pump is positioned below the liquid level or manually prime the pump by pouring a small amount of liquid into the inlet port before starting.

2. Starting the Pump

  • Press the LED-embedded power switch to turn the pump ON. The LED will illuminate green when active.
  • Monitor the flow of liquid. The pump can transfer up to 10 gallons per minute (GPM) of tap water.
  • The pump is capable of transferring a 60% water / 40% propylene glycol mixture, suitable for HVAC and refrigeration applications.
DEWALT Transfer Pump actively transferring water from a bucket

Figure 3: The pump in operation, demonstrating its ability to transfer up to 10 GPM of tap water. Note the connected hoses for intake and discharge.

3. Stopping the Pump

  • Press the LED-embedded power switch again to turn the pump OFF. The LED will extinguish.
  • Disconnect hoses and drain any remaining liquid from the pump and hoses.

4. Positioning the Pump

  • The pump can be positioned horizontally or vertically for operation, providing versatility in various work environments.

Maintenance

1. Cleaning the Impeller

  • If the pump's performance decreases or it becomes clogged, the impeller may need cleaning.
  • Disconnect the battery pack.
  • Remove the four screws securing the impeller cover.
  • Carefully remove the impeller cover and the impeller.
  • Clean any debris from the impeller and the pump housing.
  • Reassemble the impeller and cover, ensuring all screws are tightened securely.
Hand holding a pump impeller for cleaning or replacement

Figure 4: Demonstrates the ease of accessing and cleaning or replacing the impeller, a key maintenance task for optimal pump function.

2. Storage

  • After each use, drain all liquid from the pump and hoses to prevent freezing or corrosion.
  • Store the pump in a dry, protected area away from extreme temperatures.
  • Remove the battery pack during storage.

Troubleshooting

ProblemPossible CauseSolution
Pump does not startBattery not installed or dischargedInstall a charged 20V MAX battery pack.
No or low liquid flow
  • Hoses clogged or kinked
  • Impeller clogged with debris
  • Pump not primed
  • Air leak in intake hose
  • Check and clear hoses.
  • Clean the impeller (refer to Maintenance section).
  • Ensure pump is primed or below liquid level.
  • Check all connections for tightness.
Pump runs but no liquid transfersPump not primed or air in systemEnsure pump is fully primed and all air is expelled from the system.

Specifications

FeatureDetail
Model NumberDCE050B
BrandDEWALT
Power Source20V MAX Battery (sold separately)
Maximum Flow Rate (Tap Water)10 Gallons Per Minute (GPM)
Maximum Lifting Height (Tap Water)25 Feet
Maximum Head Height (Tap Water)45 Feet (at 4.5 GPM)
Liquid CompatibilityWater, 60% Water / 40% Propylene Glycol Mixture
Product Dimensions (L x W x H)16.19" x 6.69" x 9.82"
Item Weight10.14 pounds
UPC885911436922
Included Components(1) 20V MAX* Transfer Pump (Bare Tool Only)

Warranty and Support

For warranty information, service, or technical support, please contact DEWALT customer service or visit the official DEWALT website. Keep your proof of purchase for warranty claims.

DEWALT Customer Service: Refer to your product packaging or the official DEWALT website for the most current contact information.

Online Resources: Visit the DEWALT Store on Amazon

© 2025 DEWALT. All rights reserved. Specifications are subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.