1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of your Moonshan 100 GPD Reverse Osmosis (RO) System Booster Pump. This pump is designed to enhance the performance of RO systems by increasing water pressure, ensuring efficient filtration and consistent water flow. Please read this manual thoroughly before installation and use to ensure proper function and safety.

Comparison of water flow before and after installing the booster pump

Image 1.1: Visual comparison showing improved water flow from a faucet after the booster pump installation, demonstrating enhanced pressure and purity.

2. Package Contents

Verify that all components listed below are included in your package. If any items are missing or damaged, please contact customer support.

Detailed view of the Moonshan 100 GPD RO Booster Pump and all included accessories

Image 2.1: The booster pump and its complete accessory kit, including various connectors, tubing, power adapter, and a hex wrench.

  • 100 GPD Booster Pump
  • High-Pressure Switch
  • 24V Power Adapter
  • Connection Wire
  • 1/4'' RO Water Tube (3.28 inches)
  • 3/8'' to 1/4'' Quick Connector (I-Type) x2 (Pre-installed)
  • 3/8'' to 1/4'' Quick Connector (L-Type) x2
  • 2.5mm T-shaped Flat Head Hex Wrench

Note: The connection wire is pre-wired before you receive the machine.

3. Installation Guide

The Moonshan booster pump features a quick-connection design for straightforward installation. Follow these steps to integrate the pump into your RO system.

3.1 Quick Connection Design

Diagram showing the quick-connect terminal cable and 1/4 inch quick connector for easy setup

Image 3.1: Illustration of the quick-connect terminal cable and 1/4'' quick connector, highlighting the plug-and-play installation process.

The pump utilizes a quick-plug fluid interface design, simplifying the wiring process. Simply plug the components together.

3.2 System Integration Diagram

Diagram illustrating the connection of the booster pump and high-pressure switch within an RO system under a sink

Image 3.2: A schematic showing the booster pump, RO unit, storage tank, and high-pressure switch connected in a typical under-sink RO water filtration setup.

  1. Identify Components: Locate your RO system, storage tank, and the new booster pump and high-pressure switch.
  2. Connect High-Pressure Switch: Install the high-pressure switch on the purified water line, typically between the RO membrane and the storage tank. Ensure the flow direction is correct.
  3. Connect Booster Pump: Install the booster pump on the inlet water line to the RO system, before the RO membrane. Ensure the inlet and outlet ports are correctly oriented.
  4. Electrical Connections: Connect the high-pressure switch to the booster pump using the provided connection wire. Then, connect the 24V power adapter to the pump and plug it into a power outlet.
  5. Secure Connections: Ensure all quick-connect fittings are securely seated to prevent leaks.

4. Operating Instructions

4.1 Automatic Start/Stop Function

The integrated high-pressure switch automatically controls the pump's operation. When the RO storage tank pressure reaches a preset level (indicating the tank is full), the high-pressure switch will turn off the pump. When water is drawn from the tank and the pressure drops, the switch will activate the pump again to refill the tank. This function conserves energy and extends the lifespan of the pump.

4.2 Adjustable Working Pressure

Close-up of a hand adjusting the pressure screw on the booster pump with a hex wrench

Image 4.1: A user adjusting the working pressure of the pump using the provided hex wrench on the pressure adjustment screw.

The working pressure of the pump can be adjusted to suit environmental conditions and specific RO system requirements. Use the included 2.5mm T-shaped flat head hex wrench to adjust the pressure screw located on the pump. Turning the screw clockwise typically increases pressure, while turning it counter-clockwise decreases pressure. Adjust gradually and monitor your system's performance.

5. Maintenance

To ensure optimal performance and longevity of your Moonshan booster pump, consider the following maintenance guidelines:

  • Regular Inspection: Periodically check all connections for leaks. Ensure the pump and tubing are free from kinks or obstructions.
  • Cleanliness: Keep the exterior of the pump clean and free from dust or debris.
  • Filter Replacement: Ensure your RO system's pre-filters and membrane are replaced according to the manufacturer's recommendations. Clogged filters can put undue strain on the booster pump.
  • Storage: If the pump will not be used for an extended period, drain any water from it and store it in a dry, cool place.

6. Troubleshooting

If you encounter issues with your booster pump, refer to the following common problems and solutions:

ProblemPossible CauseSolution
Pump does not turn onNo power; Faulty power adapter; High-pressure switch engaged (tank full); Loose wiring.Check power connection; Test power adapter; Check tank pressure; Secure all electrical connections.
Low water pressure/flowClogged filters; Incorrect pressure adjustment; Air in the system; Pump malfunction.Replace filters; Adjust pressure screw; Bleed air from the system; Contact support if pump is faulty.
Pump runs continuouslyLow-pressure switch not working; High-pressure switch not engaging; Leak in the system; Tank not filling.Inspect pressure switches; Check for leaks; Ensure RO membrane is functioning.
Excessive noise or vibrationLoose mounting; Air in pump; Worn components.Ensure pump is securely mounted; Bleed air; Contact support if noise persists.

7. Specifications

Technical details for the Moonshan 100 GPD RO System Booster Pump.

Booster pump with text indicating it is designed for RO systems under 100 GPD and showing inlet pressure range

Image 7.1: The booster pump, emphasizing its compatibility with RO systems up to 100 GPD and its ability to boost inlet pressure from below 40 PSI to 60-80 PSI.

  • Model: MS-RO-100G
  • Brand: Moonshan
  • Style: 100GPD
  • Material: Plastic
  • Product Dimensions: 7.3"L x 4"W x 3.6"H
  • Item Weight: 6 Pounds
  • Power Source: Corded Electric
  • Maximum Flow Rate: 1.2 Liters Per Minute
  • Maximum Lifting Height: 6.56 Feet
  • Input Pressure Range: Boosts from 30-40 psi to 60-80 psi
  • Special Features: Adjustable Pressure, Auto Start/Stop Function, Quick Connection Design, Low Voltage (24V)

Important Note: This pump is not recommended for RO systems above 100 GPD.

8. Warranty and Support

Moonshan is committed to providing reliable products. This product typically comes with a one-year warranty from the date of purchase, covering manufacturing defects. For warranty claims, technical assistance, or any questions regarding your booster pump, please contact Moonshan customer support through the retailer where the product was purchased or visit the official Moonshan store online.

For further information and support, you may visit the Moonshan Store on Amazon.

Related Documents - MS-RO-100G

Preview Moonshan Automatic Filling Production Line: MS-3L Filling Machine & MS-1011 Conveyor Belt Manual
Comprehensive guide to the Moonshan MS-3L Intelligent Liquid Filling Machine and MS-1011 Conveyor Belt production line. Includes specifications, installation, troubleshooting, and customization options for industrial applications.
Preview Moonshan Automatic Gate Opener MS-GO-1 User Manual
Comprehensive user manual for the Moonshan MS-GO-1 Automatic Gate Opener system, detailing installation, operation, safety, and maintenance for medium-duty swing gates up to 12ft and 551lbs.
Preview Moonshan Electric Liquid Filling Machine User Manual
Comprehensive user manual for Moonshan Electric Liquid Filling Machines, covering operation, technical parameters, installation, maintenance, and troubleshooting for various pump types including diaphragm and peristaltic pumps. Learn how to achieve precise filling for liquids in pharmaceutical, chemical, food, cosmetic, and beverage industries.
Preview Bluonics Domestic RO Unit Installation and Maintenance Manual
This manual provides comprehensive instructions for the installation and maintenance of the Bluonics Domestic RO Unit, a 5-stage reverse osmosis filtration system. It covers system components, troubleshooting, and operational guidelines to ensure optimal performance and water quality.
Preview AquaFX Whale Shark 7-Stage RO/DI System: Installation, Maintenance, and Troubleshooting Guide
Comprehensive guide for the AquaFX Whale Shark 7-Stage Premium RO/DI Water Purification System, covering installation, filter replacement, maintenance, operational parameters, troubleshooting, and warranty information.
Preview Crystal Quest THUNDER Series Undersink Reverse Osmosis Water Filter System Installation and Operation Guide
Comprehensive installation and operation guide for the Crystal Quest THUNDER Series Undersink Reverse Osmosis Water Filter System, covering setup, maintenance, troubleshooting, and warranty information.