Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of your VEVOR Register Booster Fan, Model HAB-612W. Please read this manual thoroughly before using the product to ensure proper function and safety. Keep this manual for future reference.
Safety Instructions
- Ensure the power supply voltage matches the fan's requirements (110V).
- Do not operate the fan with a damaged cord or plug. If damaged, contact VEVOR support.
- Keep fingers and foreign objects away from the fan blades during operation.
- Do not immerse the fan or its electrical components in water or other liquids.
- Unplug the fan from the power outlet before cleaning or performing any maintenance.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Do not block the air inlets or outlets.
- Install the fan securely in the vent opening to prevent accidental dislodgement.
Package Contents
Verify that all items are present in your package:
- VEVOR Register Booster Fan (1 unit)
- Remote Control (1 unit)
- Power Adapter (1 unit)
- Mounting Screws (2 units)
- Cable Ties (for cord management, quantity may vary)

Product Features
- Compatible Vent Size: Designed for standard 6 x 12 inch (12-12.6 x 5.12-6.7 inch) floor or wall vents.
- Remote Control: Handheld remote for convenient adjustment of fan speed and modes from up to 26 feet away.
- Programmable LCD Controller: Features a temperature sensor for automatic airflow adjustment based on set room temperature. The screen automatically turns off to save power.
- Energy-Efficient PWM DC Motor: 6W motor reduces energy consumption. Operates quietly, with a lowest noise level of 18dB.
- Optimal Airflow: Improves air distribution from HVAC systems with a 160 CFM capacity and 10 adjustable speeds.
- Durable Construction: Aluminum frame with a refined surface.


Setup and Installation
- Prepare the Vent Opening: Ensure the existing vent opening is clean and clear of any obstructions. The fan is designed for openings between 12-12.6 inches in length and 5.12-6.7 inches in width.
- Position the Fan: Carefully place the VEVOR Register Booster Fan into the vent opening. Ensure it sits flush with the floor or wall surface.
- Secure the Fan: Use the provided mounting screws to secure the fan to the vent opening. This prevents movement and ensures stable operation.
- Connect Power: Plug the power adapter into the fan unit, then plug the adapter into a standard 110V electrical outlet.
- Cable Management: Use the included cable ties to neatly manage any excess power cord, preventing tripping hazards.


Operating Instructions
Using the LCD Controller
The fan features an integrated LCD controller for direct adjustments and monitoring.
- Power On/Off: Press the power button on the unit or remote to turn the fan on or off.
- Mode Button: Press the "Mode" button (three horizontal lines icon) to cycle through different operating modes (e.g., Temperature Control, Manual Speed).
- Up/Down Arrows: Use the "Up" and "Down" arrow buttons to adjust fan speed, set temperature, or navigate menu options depending on the selected mode.
- Temperature Control Mode: In this mode, the fan automatically adjusts its speed based on the ambient temperature detected by its sensor and your set target temperature. The screen will display the current temperature and the target temperature.
- Screen Auto-Off: The LCD screen will automatically turn off after a period of inactivity to save power and prevent light disturbance.
Using the Remote Control
The remote control provides convenient access to all fan functions.
- Power Button: Turns the fan on or off.
- Speed Adjustment: Buttons labeled "SPEED" or arrow icons allow you to increase or decrease the fan speed (10 levels available).
- Temperature Setting: Buttons labeled "TEMP" or arrow icons allow you to set the desired temperature for automatic operation.
- Mode Selection: Buttons for "COOL" (snowflake icon) and "HEAT" (flame icon) to select the desired operating mode.
- C/F Toggle: Button to switch between Celsius and Fahrenheit temperature display.


Maintenance
Regular maintenance ensures optimal performance and longevity of your VEVOR Register Booster Fan.
- Cleaning:
- Before cleaning, always unplug the fan from the power outlet.
- Wipe the exterior surfaces of the fan with a soft, damp cloth. Do not use abrasive cleaners or solvents.
- Periodically, use a vacuum cleaner with a brush attachment to remove dust and debris from the fan blades and grilles.
- Storage: If storing the fan for an extended period, unplug it, clean it thoroughly, and store it in a cool, dry place away from direct sunlight.
Troubleshooting
If you encounter issues with your VEVOR Register Booster Fan, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Fan does not turn on. | No power supply; Power adapter not connected; Remote control batteries dead. | Check if the power adapter is securely plugged into both the fan and the wall outlet. Ensure the outlet has power. Replace remote control batteries. |
| Fan runs but airflow is weak. | Fan speed set too low; Obstruction in vent or fan; Dirty fan blades. | Increase fan speed using the controller or remote. Check for and remove any obstructions in the vent or around the fan. Clean fan blades and grilles. |
| Fan is noisy. | Fan speed set too high; Loose installation; Obstruction hitting blades. | Reduce fan speed. Ensure the fan is securely mounted in the vent opening. Check for any debris or objects interfering with the fan blades. |
| Remote control not working. | Dead batteries; Out of range; Obstruction between remote and fan. | Replace remote control batteries. Ensure you are within the 26-foot effective range. Remove any objects blocking the signal path. |
| Temperature control not accurate. | Sensor obstructed or dirty; Incorrect temperature setting. | Ensure the temperature sensor area is clean and unobstructed. Verify the desired temperature setting. |
Specifications
| Feature | Detail |
|---|---|
| Model Number | HAB-612W |
| Brand | VEVOR |
| Color | White |
| Material | Aluminum |
| Product Dimensions (D x W x H) | 2"D x 13"W x 7.4"H (51mm D x 330mm W x 188mm H approx.) |
| Item Weight | 1.98 lbs (0.9 kg) |
| Power Source | AC (110 Volts) |
| Power Consumption | 3.8W (PWM DC Motor) |
| Air Flow Capacity | 160 CFM (Cubic Feet Per Minute) |
| Noise Level | 18 dB (lowest setting) |
| Number of Speeds | 10 |
| Control Method | LCD Panel & Remote Control |
| Remote Control Range | Up to 26 ft (8 meters) |
| Power Cord Length | 12 ft (3.6 meters) |
| Fit Duct Size | 12-12.6 x 5.12-6.7 inch |
| Recommended Uses | Ventilating, Heating, Cooling |

Warranty and Support
VEVOR products come with a standard warranty. For specific warranty details, technical support, or service inquiries, please refer to the warranty card included with your product or visit the official VEVOR website. You can also contact VEVOR customer service directly for assistance.
Official VEVOR Website: www.vevor.com