1. Introduction
This manual provides essential information for the safe and efficient operation of your ETURBEV SU800-WJMB High-Performance Variable Frequency Drive (VFD) Inverter. Please read this manual thoroughly before installation, operation, or maintenance to ensure proper use and prevent potential hazards.
The SU800-WJMB VFD is designed to control the speed and torque of 3-phase AC motors, offering precise control and energy savings in various industrial applications.
2. Safety Information
WARNING: Improper installation or operation may result in electric shock, fire, or serious injury. Always follow safety precautions.
- Only qualified personnel should install, operate, and maintain this VFD.
- Ensure the power supply is disconnected before performing any wiring or maintenance. Wait at least 5 minutes after power-off for capacitors to discharge.
- Verify correct voltage and current ratings before connecting to the motor and power supply.
- Do not touch internal components or circuit boards when power is applied.
- Install the VFD in a clean, dry, well-ventilated area, away from direct sunlight, corrosive gases, and excessive vibration.
- Proper grounding is essential to prevent electric shock.
3. Product Overview
The ETURBEV SU800-WJMB VFD features a compact design with an integrated control panel for easy operation and monitoring.
3.1. External View and Components


3.2. Control Panel
The control panel allows for parameter setting, status monitoring, and manual operation. Key elements include:
- Digital Display: Shows frequency, current, voltage, and other operational data.
- RUN/STOP Buttons: To start and stop the motor.
- Directional Keys (▲ ▼ ◀ ▶): For navigation and value adjustment.
- PRG/FUNC Button: To enter/exit programming mode and select functions.
- ENTER Button: To confirm selections and save parameters.

4. Setup and Installation
4.1. Mounting
Mount the VFD vertically on a flat, non-flammable surface. Ensure adequate clearance around the unit for proper ventilation (at least 10 cm above and below, 5 cm on sides).
4.2. Wiring
CAUTION: All wiring must be performed by a qualified electrician. Ensure power is OFF before wiring.
Refer to the internal wiring diagram for terminal connections. The main power terminals are typically labeled R, S, T (input) and U, V, W (output to motor). Ensure proper grounding (PE terminal).


Input Power: Connect the appropriate 220V or 380V AC power supply to the input terminals (R, S, T or L1, L2, L3 depending on model/region).
Motor Connection: Connect the 3-phase motor to the output terminals (U, V, W).
Control Wiring: Connect external control signals (e.g., start/stop, speed reference, fault reset) to the designated control terminals as per your application requirements. Refer to the detailed wiring diagram in the full product manual for specific terminal functions.
5. Operating Instructions
5.1. Initial Power-Up
- After verifying all wiring is correct and secure, apply power to the VFD.
- The digital display will illuminate, showing the default frequency or a status code.
5.2. Basic Operation (Panel Control)
- Press the RUN button to start the motor. The display will show the output frequency.
- Use the ▲ and ▼ buttons to adjust the output frequency (motor speed).
- Press the STOP button to stop the motor.
5.3. Parameter Setting
To access and modify parameters:
- Press the PRG/FUNC button to enter programming mode.
- Use the ▲ and ▼ buttons to navigate through parameter groups and individual parameters.
- Press ENTER to select a parameter and view its current value.
- Use ▲ and ▼ to change the parameter value.
- Press ENTER again to save the new value.
- Press PRG/FUNC to exit programming mode.
Common parameters include:
- Motor Parameters: Rated power, rated voltage, rated current, rated frequency.
- Acceleration/Deceleration Time: Time taken for the motor to reach/stop from maximum speed.
- Max/Min Frequency: Upper and lower limits for output frequency.
- Control Mode: V/F control, vector control (if supported).
Refer to the complete product manual for a detailed list of all parameters and their functions.
6. Maintenance
WARNING: Disconnect all power before performing any maintenance. Wait for capacitors to discharge.
- Regular Cleaning: Keep the VFD clean and free from dust and debris. Use compressed air to clean ventilation openings and cooling fins.
- Inspection: Periodically check for loose connections, damaged wiring, or signs of overheating (discoloration).
- Environmental Check: Ensure the operating environment remains within specified temperature and humidity ranges.
- Fan Check: Ensure cooling fans are operating correctly and are not obstructed.
7. Troubleshooting
This section provides solutions for common issues. For complex problems, contact technical support.
| Problem | Possible Cause | Solution |
|---|---|---|
| VFD does not power on | No input power; Blown fuse; Internal fault | Check power supply; Replace fuse; Contact support |
| Motor does not run | Incorrect wiring; Parameter settings; Emergency stop active | Verify wiring; Check motor parameters; Reset emergency stop |
| Overcurrent fault | Motor overload; Short circuit; Rapid acceleration/deceleration | Reduce load; Check motor/cables; Increase Accel/Decel time |
| Overvoltage fault | High input voltage; Rapid deceleration with high inertia load | Check input voltage; Increase Decel time; Consider braking resistor |
| Overheat fault | Poor ventilation; Ambient temperature too high; Fan failure | Improve ventilation; Reduce ambient temp; Check/replace fan |
8. Specifications
The following are general specifications for the ETURBEV SU800-WJMB VFD Inverter. Specific ratings may vary by model variant (e.g., 0.75KW, 1.5KW, 2.2KW, 5.5KW).
- Model: SU800-WJMB
- Input Voltage: 220V / 380V AC (depending on specific model)
- Output Voltage: 0-Input Voltage (3-phase)
- Output Frequency: 0-400 Hz
- Rated Power: 0.75KW, 1.5KW, 2.2KW (for 220V/380V models), up to 5.5KW (for 380V models)
- Control Method: V/F control, Vector control (sensorless)
- Protection: Overcurrent, Overvoltage, Undervoltage, Overheat, Overload, Short circuit, etc.
- Operating Temperature: -10°C to 40°C (14°F to 104°F)
- Humidity: < 90% RH (non-condensing)
- ASIN: B0F9SL1X8Y
Note: The product dimensions and weight provided in some listings (e.g., 0.39 x 0.39 x 0.39 inches, 1.76 ounces) are generic placeholders and do not reflect the actual physical characteristics of this industrial device. Actual dimensions and weight will be significantly larger and heavier.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the documentation included with your purchase or contact your authorized ETURBEV distributor or customer service. Please have your model number (SU800-WJMB) and purchase details ready when contacting support.
For further assistance, visit the official ETURBEV website or contact their customer service department.