1. Important Safety Information

Please read and understand all instructions before using this product. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Outdoor Use Only: This timer is designed for outdoor use. Ensure all connections are secure and protected from direct water exposure.
  • Grounding: Always plug the timer into a grounded 3-prong outlet. Do not remove the grounding prong.
  • Electrical Rating: Do not exceed the maximum electrical rating of 15A/1800W. Overloading the timer can cause damage or fire.
  • Water Protection: The unit is weatherproof, but ensure the protective covers for unused outlets are securely closed. Avoid submerging the unit in water.
  • Placement: Install the stake timer in a location where it is not a tripping hazard and where the cord is not easily damaged. Ensure the outlets are at least 1 foot above ground level.
  • Children and Pets: Keep the timer and connected devices out of reach of children and pets.
  • Maintenance: Disconnect power before cleaning or performing any maintenance.

2. Product Overview

The DEWENWILS Outdoor Digital Power Stake Timer is designed to automate your outdoor lighting and appliances with ease and reliability. It features multiple grounded outlets, programmable settings, and a durable, weatherproof construction.

Diagram showing key features of the DEWENWILS outdoor power stake timer, including 6 grounded outlets, 7-day programmability, 8 ON/OFF settings, screen and buttons, and a 3-month power backup feature.

Figure 2.1: Key Features and Components

Key Features:

  • 6 Grounded Outlets: Control up to six devices simultaneously.
  • 7-Day Programmable: Set automatic ON/OFF schedules that repeat weekly.
  • 8 ON/OFF Settings: Allows up to 8 distinct ON/OFF programs with a minimum setting time of 1 minute.
  • Weatherproof Design: Built with a weather-resistant housing to withstand rain, snow, and dust, suitable for various outdoor environments.
  • Built-in Backup Battery: Retains programmed settings for up to 3 months during power outages.
  • 6FT 14/3C Extension Cord: Provides flexible placement options.
  • Overload Protection: Integrated 15A circuit breaker protects connected devices from overload or short-circuit damage.
  • ETL Certified: Ensures safety and quality standards are met.

3. Specifications

Detailed diagram of the DEWENWILS outdoor power stake timer showing dimensions and labeled components such as the digital LCD, control buttons, 6 grounded outlets, waterproof cover, heavy-duty extension cord, and two-section long stake.

Figure 3.1: Product Dimensions and Components

FeatureSpecification
Model NumberLPU06FG-YJ
Input Voltage125V~, 60Hz
Max Power Rating15A/1800W
Number of Outlets6 Grounded Outlets
Cord Length6FT (14/3C SJTW)
Programmable Settings8 ON/OFF programs, 7-day cycle
Minimum Setting Time1 Minute
Backup BatteryYes (up to 3 months)
ProtectionOverload Protection Switch
CertificationsETL Listed
MaterialMetal, Plastic (Flame-retardant PC housing)
Item Weight0.8 Pounds

4. Setup and Installation

Follow these steps to properly set up and install your DEWENWILS Outdoor Digital Power Stake Timer.

4.1 Assembling the Stake

Diagram illustrating the assembly of the two-section stake. One section connects to the timer unit, and the other section, a pointed stake, connects to the first section for ground insertion.

Figure 4.1: Stake Assembly

  1. Connect the two sections of the stake by twisting them together until secure.
  2. Attach the assembled stake to the bottom of the timer unit by twisting it into place.

4.2 Ground Installation

The DEWENWILS outdoor power stake timer installed in a grassy area, with the stake firmly in the ground and the unit elevated at least 1 foot above the ground. Rain is visible, demonstrating its weatherproof capability.

Figure 4.2: Ground Installation

  1. Choose a suitable outdoor location with firm ground.
  2. Insert the pointed end of the stake firmly into the ground, ensuring the timer unit is stable and upright.
  3. Ensure the bottom of the timer unit, where the outlets are located, is at least 1 foot (30 cm) above ground level to prevent water ingress.

4.3 Wall Mounting (Optional)

The DEWENWILS outdoor power stake timer shown mounted on a wall, with a close-up inset of the mounting holes on the back of the unit. The clear protective cover is open, revealing the outlets and digital display.

Figure 4.3: Wall Mounting Option

If ground installation is not preferred, the timer can be wall-mounted:

  1. Locate the mounting holes on the back of the timer unit.
  2. Use appropriate screws (not included) to securely fasten the timer to a wall or sturdy vertical surface. Ensure the mounting location is protected from direct heavy rain if possible, and that the unit remains upright.

4.4 Connecting Power and Devices

The DEWENWILS outdoor power stake timer with multiple devices plugged into its 6 grounded outlets. The unit is placed outdoors near a tent with string lights, demonstrating its use for various electrical appliances.

Figure 4.4: Connecting Devices

  1. Plug the timer's 6FT extension cord into a grounded outdoor electrical outlet.
  2. Open the clear protective cover.
  3. Plug your outdoor lights or appliances into the 6 grounded outlets on the timer.
  4. Ensure the total wattage of all connected devices does not exceed 1800W (15A).
  5. Close the protective cover securely to maintain weatherproof integrity.

5. Operating Instructions

The timer features a digital display and several buttons for setting the clock and programming schedules.

Close-up of the DEWENWILS digital timer's screen and control buttons. The screen displays 'MO PM 6:57 AUTO OFF'. Buttons include WEEK, HOUR, MIN, R, RESET, CLOCK, PROG, and MANUAL.

Figure 5.1: Digital Display and Control Buttons

5.1 Button Functions:

  • CLOCK: Used to set the current time and day.
  • PROG: Used to enter and exit programming mode for ON/OFF schedules.
  • MANUAL: Toggles between ON, OFF, and AUTO modes.
  • WEEK: In CLOCK mode, sets the current day. In PROG mode, selects days for a program.
  • HOUR: Adjusts the hour.
  • MIN: Adjusts the minute.
  • R (Reset Program): Clears the current program setting.
  • RESET: Clears all settings and resets the timer to factory defaults. Use a pointed object (e.g., pen tip) to press.

5.2 Setting the Current Time and Day:

  1. Press the CLOCK button. The display will show the current time.
  2. While holding the CLOCK button, press WEEK to set the current day (MO, TU, WE, TH, FR, SA, SU).
  3. While holding the CLOCK button, press HOUR to set the current hour (12-hour format with AM/PM).
  4. While holding the CLOCK button, press MIN to set the current minute.
  5. Release the CLOCK button to save the settings.

5.3 Manual Mode:

Press the MANUAL button to cycle through the following modes:

  • ON: All connected devices will remain ON continuously, overriding any programmed schedules.
  • OFF: All connected devices will remain OFF continuously, overriding any programmed schedules.
  • AUTO: The timer will operate according to the programmed ON/OFF schedules. This is the default and recommended mode for automated operation.

6. Programming the Timer

The timer allows for up to 8 distinct ON/OFF programs. Each program can be set for specific days of the week.

6.1 Setting ON/OFF Programs:

  1. Press the PROG button once. The display will show "1 ON" and the time will flash. This is for the first ON time.
  2. Press WEEK repeatedly to select the desired day(s) for this program. Options include individual days, weekdays (MO TU WE TH FR), weekends (SA SU), or all days (MO TU WE TH FR SA SU).
  3. Press HOUR to set the desired hour for the ON time.
  4. Press MIN to set the desired minute for the ON time.
  5. Press PROG again. The display will show "1 OFF" and the time will flash. This is for the first OFF time.
  6. Repeat steps 2-4 to set the desired day(s), hour, and minute for the OFF time. Ensure the OFF time is set for the same day(s) as the ON time.
  7. To set additional programs (up to 8), press PROG again and repeat steps 1-6 for "2 ON", "2 OFF", and so on.
  8. After setting all desired programs, press the CLOCK button to exit programming mode and return to the current time display.

6.2 Clearing a Program:

If you need to clear a specific ON/OFF program:

  1. Press the PROG button repeatedly until the program number you wish to clear is displayed (e.g., "3 ON").
  2. Press the R button. The display will show "--:--", indicating the program has been cleared.
  3. Repeat for the corresponding OFF time (e.g., "3 OFF").
  4. Press CLOCK to exit.

6.3 Resetting All Settings:

To clear all programmed settings and reset the timer to its factory default state:

  • Use a small pointed object (like a pen tip) to press the RESET button.
  • The display will clear, and you will need to set the current time and reprogram any desired schedules.

7. Maintenance

Proper maintenance ensures the longevity and safe operation of your timer.

  • Cleaning: Disconnect the timer from the power source before cleaning. Wipe the unit with a damp cloth. Do not use abrasive cleaners or immerse the unit in water.
  • Inspection: Periodically inspect the power cord and the timer unit for any signs of damage, such as cuts, fraying, or cracks. If damage is found, discontinue use and replace the unit.
  • Storage: When not in use for extended periods, store the timer in a dry, cool place away from direct sunlight.
  • Overload Protection: If the overload protection switch trips (the timer stops working), disconnect some devices, then press the reset button on the side of the unit to restore power.

8. Troubleshooting

If you encounter issues with your DEWENWILS Outdoor Digital Power Stake Timer, refer to the following common problems and solutions.

ProblemPossible CauseSolution
Timer does not turn ON/OFF at programmed times.1. Timer is not in AUTO mode.
2. Incorrect program settings.
3. Current time/day is incorrect.
1. Press MANUAL until "AUTO" is displayed.
2. Review and re-enter program settings carefully (Section 6.1).
3. Reset current time and day (Section 5.2).
Display is blank or dim.1. No power to the unit.
2. Backup battery low (if recently unplugged).
1. Ensure the timer is securely plugged into a live outlet.
2. Plug the timer in for several hours to charge the internal backup battery. If the issue persists, the unit may be faulty.
Connected devices do not receive power.1. Timer is in OFF mode.
2. Overload protection tripped.
3. Faulty device or connection.
1. Press MANUAL to switch to ON or AUTO mode.
2. Reduce the load, then press the overload protection reset button on the side of the unit.
3. Test the device directly in a working outlet. Check all connections.
Cannot set programs or time.Unit is locked or unresponsive.Press the RESET button with a pointed object to clear all settings and try again.

9. Warranty and Support

DEWENWILS products are designed for reliability and performance. This product comes with a standard manufacturer's warranty against defects in materials and workmanship.

  • Warranty Period: Please refer to the product packaging or the official DEWENWILS website for specific warranty duration.
  • Customer Support: For technical assistance, troubleshooting, or warranty claims, please contact DEWENWILS customer service. Contact information can typically be found on the product packaging, the DEWENWILS official website, or through your retailer.
  • Online Resources: Visit the DEWENWILS Store on Amazon for additional product information and support.

© 2026 DEWENWILS. All rights reserved.

Model: LPU06FG-YJ

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.