1. Introduction
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Amana HEH073K25DXXX 7,000 BTU Packaged Terminal Air Conditioner (PTAC) unit. This high-efficiency unit features a heat pump, operates on 208/230 Volts and 15 Amps, and is designed to provide year-round comfort. Please read this manual thoroughly before installation and use, and retain it for future reference.

Figure 1: Amana HEH073K25DXXX PTAC Unit, showing the complete exterior housing.
2. Safety Information
Always observe the following safety precautions to reduce the risk of fire, electric shock, or injury to persons.
- WARNING: RISK OF ELECTRIC SHOCK. Disconnect all remote electric power supplies before servicing. This compartment must be closed except when servicing.
- Installation and servicing must be performed by qualified personnel only.
- Ensure the unit is properly grounded to prevent electrical shock.
- Do not operate the unit with damaged wiring or components.
- Keep flammable materials away from the unit.
- Ensure proper ventilation around the unit as specified in installation instructions.

Figure 2: Internal wiring compartment with safety warning label. Always disconnect power before accessing this area.
3. Product Overview and Features
The Amana HEH073K25DXXX PTAC unit is designed for optimal performance and user comfort. Key features include:
- High Efficiency: Engineered for energy-saving operation.
- Heat Pump Functionality: Provides both cooling and heating capabilities.
- Quiet Operation: Features upgraded DC motors for reduced noise levels (52 dB).
- Smart Door Economizer: Allows the unit to bring in cool, dry outside air to maintain room temperatures, reducing energy consumption.
- Easy Pull-Out Filters: Simplifies routine maintenance.
- Room Freeze Protection: Automatically activates to prevent freezing in unoccupied rooms.
- Zero Floor Clearance: Designed for flexible installation options.
- 100% Run Tested: Each unit undergoes rigorous testing to ensure reliability.
- Assembled in the USA: Quality manufacturing.

Figure 3: Front view of the Amana PTAC unit, showcasing its sleek design and air vents.
4. Setup and Installation
This PTAC unit is designed for through-the-wall installation. Professional installation is highly recommended to ensure proper function and safety.
4.1 Pre-Installation Considerations
- Power Requirements: The unit requires a 208/230 Volt, 15 Amp electrical supply. Ensure the electrical circuit meets these specifications.
- External Thermostat: This unit does not have an on-board control panel. An external thermostat (sold separately) is required for operation. Plan for its installation and wiring.
- Wall Sleeve: A compatible wall sleeve is necessary for through-the-wall installation.
- Included Components: Verify that the front cover and installation hardware are present.
4.2 Installation Steps (Summary)
- Prepare the wall opening and install the wall sleeve according to its specific instructions.
- Carefully slide the PTAC unit into the wall sleeve.
- Connect the unit to the dedicated 208/230V, 15 Amp electrical supply. Refer to local electrical codes and the unit's wiring diagram.
- Install and wire the external thermostat to the unit's control board.
- Secure the unit within the sleeve and install the front cover.
- Perform a test run to ensure all functions operate correctly.

Figure 4: Example of a 208/230V, 15 Amp power plug, similar to what may be used with this unit. Ensure proper electrical connection.

Figure 5: Internal view of the PTAC unit, showing the fan and coil components. Access for installation and maintenance.
5. Operating Instructions
The Amana HEH073K25DXXX PTAC unit is controlled exclusively by an external thermostat. Once the unit is properly installed and connected to an external thermostat, you can manage its operation.
5.1 Basic Operation via External Thermostat
- Power On/Off: Use the external thermostat to turn the unit on or off.
- Mode Selection: Select desired operating mode (Cool, Heat, Fan Only) on your external thermostat. The unit will respond accordingly.
- Temperature Setting: Adjust the desired room temperature using the external thermostat's controls.
- Fan Speed: If supported by your external thermostat, adjust the fan speed (e.g., Low, Medium, High, Auto).
5.2 Smart Door Economizer Function
The integrated Smart Door Economizer feature allows the unit to utilize favorable outdoor conditions to cool the room. When the outside air is cool and dry enough, the unit can bring in this air to maintain comfort, thereby reducing the need for mechanical cooling and saving energy. This function operates automatically based on programmed settings or external thermostat commands, if applicable.
6. Maintenance
Regular maintenance ensures optimal performance and extends the lifespan of your Amana PTAC unit. Always disconnect power to the unit before performing any maintenance.
6.1 Air Filter Cleaning/Replacement
The unit is equipped with easy pull-out filters. Clean or replace filters regularly (e.g., monthly, or more frequently with heavy use) to maintain air quality and unit efficiency.
- Disconnect power to the unit at the circuit breaker.
- Locate the filter access panel, typically on the front of the unit.
- Gently pull out the air filters.
- Clean filters with a vacuum cleaner or wash with mild soap and water. Ensure filters are completely dry before reinstallation. Replace if damaged or excessively dirty.
- Reinsert the clean/new filters and close the access panel.
- Restore power to the unit.

Figure 6: Accessing the easy pull-out air filters for cleaning or replacement.
6.2 Coil Cleaning
Periodically inspect the evaporator and condenser coils for dirt and debris. If coils are dirty, professional cleaning is recommended to avoid damage and ensure efficient operation.
6.3 General Cleaning
Wipe the exterior of the unit with a soft, damp cloth. Do not use abrasive cleaners or solvents.
7. Troubleshooting
If your Amana PTAC unit is not operating correctly, refer to the following common issues and solutions. For problems not listed here, or if solutions do not resolve the issue, contact qualified service personnel.
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not turn on. | No power supply; External thermostat off or incorrectly wired; Circuit breaker tripped. | Check power connection; Ensure external thermostat is on and set correctly; Reset circuit breaker. |
| Insufficient cooling/heating. | Dirty air filter; Obstruction to airflow; Incorrect thermostat setting; Unit undersized for room. | Clean or replace air filter; Remove obstructions; Adjust thermostat setting; Consult with an HVAC professional. |
| Unusual noise. | Loose components; Debris in fan; Unit not level. | Inspect for loose parts; Check for debris and remove if safe; Ensure unit is level. If noise persists, contact service. |
| Water leakage. | Clogged condensate drain; Improper installation. | Check and clear condensate drain; Verify proper unit leveling and installation. Contact service if issue continues. |
8. Specifications
| Feature | Detail |
|---|---|
| Brand | AMANA |
| Model Number | HEH073K25DXXX |
| Cooling Capacity | 7,000 BTU (7100 British Thermal Units) |
| Heating Type | Heat Pump |
| Voltage | 208/230 Volts |
| Amperage | 15 Amps (Size of the product: 11.2 A, Wattage: 545 watts) |
| Noise Level | 52 dB |
| Product Dimensions (D x W x H) | 21.63 x 42 x 16 inches |
| Item Weight | 115 pounds |
| Installation Type | Through The Wall |
| Material Type | Metal, Plastic |
| Included Components | Front Cover, Installation Hardware |
| Special Features | Automatic Emergency Heat, Easy Pull-Out Filters, Room Freeze Protection, Zero Floor Clearance, Smart Door Economizer |
9. Warranty and Support
For warranty information, technical support, or to locate authorized service providers, please contact AMANA customer service. Keep your purchase receipt and model number (HEH073K25DXXX) readily available when contacting support.