1. Introduction and Important Safety Warnings
Thank you for choosing the VEVOR US-007/36W UV Disinfection Lamp. This device utilizes advanced UV-C light and ozone generation to effectively purify air and surfaces in unoccupied spaces. Please read this manual thoroughly before use to ensure safe and optimal operation.
CRITICAL SAFETY WARNINGS:
- DANGER: UV-C RADIATION AND OZONE EMISSION. Direct exposure to UV-C light can cause severe skin and eye damage. Ozone can be harmful if inhaled in high concentrations.
- NEVER operate this lamp in the presence of humans, pets, or plants. Ensure the area is completely clear during operation.
- After each use, THOROUGHLY VENTILATE the treated room for at least 30-60 minutes to dissipate any residual ozone before re-entry.
- Keep the device out of reach of children and individuals who cannot understand these warnings.
- Do not disassemble, modify, or attempt to repair the device yourself. Contact qualified personnel for service.
2. What's in the Box
Carefully unpack all components and check for any damage. If any items are missing or damaged, please contact VEVOR customer support.
- 1 x VEVOR US-007/36W UV Disinfection Lamp
- 1 x Remote Controller
- 1 x Alkaline Battery (23A 12V) for Remote Controller
- 1 x Sticker for Lampshade Top
- 1 x Instruction Manual (this document)
3. Product Overview
The VEVOR US-007/36W UV Disinfection Lamp is designed for comprehensive air and surface purification. It features a robust design with intuitive controls.

Image 3.1: Product Details. This image shows the main components of the VEVOR UV Disinfection Lamp, including the ABS flame-retardant lamp cover, the 110W long-lifespan light tube, the hand-operated switch on the base, and the wireless remote controller.
Key Components:
- UV-C Quartz Tube: High-transmission quartz tube emitting 253.7 nm UV-C light and 185 nm UV light for ozone generation.
- ABS Flame Retardant Lamp Cover: Provides protection for the UV-C tube.
- Base with Control Panel: Features a hand-operated switch and digital display for timer settings.
- Wireless Remote Controller: Allows convenient operation from a distance, offering ON/OFF and timer functions.

Image 3.2: Control Modes. This image illustrates the two control methods: the wireless remote control and the panel control located on the device base. It also highlights the three timer levels: 0.5 hours, 1 hour, and 2 hours.
4. Setup
- Unpack the Device: Carefully remove the UV Disinfection Lamp and all accessories from its packaging. Retain packaging for future storage or transport.
- Placement: Place the lamp on a stable, flat surface in the center of the room you wish to disinfect. Ensure there are no obstructions blocking the UV light path. The lamp is suitable for rooms up to 37 m² (approximately 400 sq ft).
- Power Connection: Plug the power cord into a standard electrical outlet (220-240V, 50Hz).
- Remote Control Battery Installation: Open the battery compartment on the back of the remote control. Insert the provided 23A 12V alkaline battery, ensuring correct polarity (+/-). Close the compartment.
- Prepare the Room: Before operation, ensure all people, pets, and plants are removed from the room. Close all doors and windows to contain the UV-C light and ozone.
5. Operating Instructions
The lamp can be operated using either the control panel on the device base or the wireless remote control.
Using the Control Panel:
- Ensure the lamp is plugged in and the room is empty.
- Press the power button on the base. The lamp will typically have a delay before turning on to allow you to leave the room safely.
- Use the timer buttons on the base to select the desired disinfection duration (0.5h, 1h, or 2h).
- Once the timer is set, the lamp will begin operation after a short delay. Immediately exit the room.
Using the Remote Control:
- Ensure the lamp is plugged in and the room is empty.
- Point the remote control towards the lamp.
- Press the 'ON' button to power on the lamp.
- Select the desired timer setting (0.5H, 1H, or 2H) using the corresponding buttons on the remote.
- The lamp will activate after a short delay. Immediately exit the room.
After Operation:
- Once the selected disinfection cycle is complete, the lamp will automatically turn off.
- DO NOT re-enter the room immediately. Open windows and doors (from outside the room if possible) to allow for thorough ventilation.
- Ventilate the room for at least 30-60 minutes to ensure all ozone has dissipated before re-entry.

Image 5.1: Ozone and UV-C Action. This image visually represents the lamp's dual action, showing UV-C light and ozone (O3) being emitted to purify the air and surfaces within a room, covering up to 37 m².
6. Maintenance
Regular maintenance ensures the longevity and effectiveness of your UV Disinfection Lamp.
Cleaning the Lamp:
- Always unplug the device from the power outlet before cleaning.
- Use a soft, dry cloth to gently wipe the exterior of the lamp and the quartz tube.
- Do not use liquid cleaners, abrasive materials, or chemical solvents, as these can damage the device or reduce the effectiveness of the UV-C tube.
- Ensure the lamp is completely dry before plugging it back in.
Remote Control Battery Replacement:
- If the remote control becomes unresponsive, replace the 23A 12V alkaline battery.
- Open the battery compartment, remove the old battery, and insert a new one with correct polarity.
- Dispose of old batteries according to local regulations.
7. Troubleshooting
If you encounter issues with your VEVOR UV Disinfection Lamp, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Lamp does not turn on. | No power supply. Remote control battery is dead. Device is faulty. | Check if the power cord is securely plugged into a working outlet. Replace the remote control battery. If the issue persists, contact VEVOR customer support. |
| Remote control is not working. | Battery is dead or incorrectly inserted. Obstruction between remote and lamp. Remote is too far from the lamp. | Replace the remote control battery and ensure correct polarity. Ensure a clear line of sight between the remote and the lamp. Operate the remote within its effective range. |
| Strong odor after disinfection. | Residual ozone in the air. | This is normal. Ensure thorough ventilation of the room for at least 30-60 minutes after use. |
8. Specifications
Detailed technical specifications for the VEVOR US-007/36W UV Disinfection Lamp.

Image 8.1: Dimensions and Specifications. This image provides a visual representation of the lamp's dimensions and lists key specifications such as model number, power, timer settings, material, wavelength, color, controller size, product size, product weight, and package contents.
| Feature | Specification |
|---|---|
| Model Number | US-007/36W |
| Power | 36 W |
| Timer Settings | 3 Levels (0.5 h / 1 h / 2 h) |
| Material | ABS |
| Wavelength | 253.7 nm + 185 nm (UV-C light + Ozone) |
| Color | Black |
| Controller Size | 4.1 x 1.7 x 0.7 in / 105 x 45 x 18 mm |
| Product Dimensions (Diameter x Height) | Φ6.5 x 16.4 in / Φ166 x 416 mm |
| Product Weight | 1.3 lb / 0.6 kg ± 3% |
| Rated Voltage Frequency | 220-240 V, 50 Hz |
| Light Source Lifespan | 8000 Hours |
| Control Method | Remote Control, Panel Control |
| Coverage Area | Up to 37 m² (approx. 400 sq ft) |
9. Warranty and Support
VEVOR products are designed for durability and performance. This product comes with a standard manufacturer's warranty. Please refer to the warranty card included in your package or visit the official VEVOR website for detailed warranty terms and conditions.
Customer Support:
If you have any questions, require technical assistance, or need to report an issue, please contact VEVOR customer support through their official website or the contact information provided with your purchase. When contacting support, please have your product model number (US-007/36W) and purchase details ready.
For more information and to register your product, visit: www.vevor.com