1. Product Overview
The FOTING 1HP Automatic Submersible Water Pump is designed for efficient water drainage in various applications such as swimming pools, ponds, and basements. This utility pump features a 1HP motor capable of draining water up to 4600 GPH (76 GPM) and lifting water up to 31 feet vertically. Its automatic water sensor ensures drainage to a low level of 1/5 inch and stops operation 15 seconds after water is no longer detected.

Figure 1: FOTING 1HP Automatic Submersible Water Pump.
2. Safety Information
Always read and understand all safety warnings and instructions before operating the pump. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Ensure the power cord and plug are in good condition before each use. Do not use if damaged.
- Do not pull the pump by its power cord. Always use the handle for lifting and positioning.
- Ensure the pump is fully submerged in water before operation to prevent dry running and motor damage.
- The pump is equipped with a built-in automatic thermal overload protector to prevent motor burnout.
- Operate the pump within its specified temperature limits (Max 95°F).
- Keep children and pets away from the pump during operation.

Figure 2: Important handling instructions: Lift by handle, do not pull by power cord.
3. Setup and Installation
- Attach Discharge Hose: The pump comes with a NPT 1-1/2" discharge size, a NPT 3/4" garden hose adapter, and a hose adapter that fits Φ1-1/2", Φ1", or NPT 1" inch hoses. Select the appropriate adapter for your hose and securely attach it to the pump's discharge outlet.
- Position the Pump: Place the pump on a stable, flat surface in the area to be drained. Ensure the pump is fully submerged in the water. For optimal performance, submerge the pump at an angle initially to allow any trapped air to escape.
- Connect Power: Plug the 16-foot power cord into a grounded electrical outlet. Ensure the outlet meets the pump's electrical requirements.

Figure 3: Various hose connector sizes and adapters for flexible connection.

Figure 4: Illustration of different hose connection methods.

Figure 5: Step-by-step setup: 1. Select pipe, 2. Plug in and submerge, 3. Drain water.
4. Operating Instructions
The FOTING 1HP Automatic Sump Pump features an intelligent water sensor for automated operation.
- Automatic Start: The pump will automatically start when the water level covers the integrated sensor.
- Automatic Shut-Off: The pump will automatically stop after 15 seconds when the water level is below 1/5 inch, ensuring minimal residual water.
- Customizable Water Control: The pump features four locating holes (A, B, C, D) for the sensor, allowing you to adjust the activation depth for varying water removal needs.

Figure 6: Automatic control sensor with adjustable water depth settings (A, B, C, D).

Figure 7: The pump can remove water down to 1/5 inch from the surface.
5. Maintenance
Regular maintenance ensures the longevity and optimal performance of your FOTING sump pump.
- Cleaning the Bottom Screen: The pump features a removable bottom screen for easy cleaning. Periodically remove the screen and clear any debris that may obstruct water intake.
- Inspect Power Cord: Regularly check the power cord for any signs of damage, cuts, or fraying. Replace if necessary.
- Storage: When not in use for extended periods, clean the pump thoroughly, dry it, and store it in a dry, protected area.

Figure 8: The removable bottom screen facilitates easy cleaning and maintenance.
6. Troubleshooting
If you encounter issues with your FOTING sump pump, refer to the following common troubleshooting tips:
- Pump Not Starting:
- Check if the pump is properly plugged into a functional power outlet.
- Ensure the water level is high enough to activate the automatic sensor.
- Verify that the power cord is not damaged.
- Reduced Flow Rate:
- Inspect the intake screen at the bottom of the pump for blockages. Clean if necessary.
- Check the discharge hose for kinks or obstructions.
- Ensure the hose diameter is appropriate for the desired flow.
- Pump Runs Continuously:
- Check if the water sensor is clean and free of debris.
- Ensure the pump is positioned correctly and the water level drops below the shut-off threshold.
- Pump Overheats and Shuts Off:
- The pump has a built-in thermal overload protector. Allow the pump to cool down before restarting.
- Ensure the pump is fully submerged and not running dry.
- Check for blockages that might be causing the motor to work harder.
For further assistance, please contact FOTING customer service.
7. Specifications
| Feature | Specification |
|---|---|
| Brand | FOTING |
| Model | 1HP AUTO SUMP PUMP |
| Power | 1 HP |
| Maximum Flow Rate | 4600 GPH (76 GPM) |
| Maximum Lifting Height | 31 Feet |
| Lowest Suction Level | 1/5 inch |
| Power Cord Length | 16 Feet |
| Material | Thermoplastic |
| Protection Type | IPX8 (Water-Resistance) |
| Max Water Temperature | 95°F |
| Discharge Sizes | NPT 1-1/2", NPT 3/4", Φ1-1/2", Φ1", NPT 1" |

Figure 9: Visual representation of pump performance metrics.

Figure 10: Pump performance curve and flow rate table at various lift heights.
8. Warranty and Support
FOTING provides a 3-year warranty for this product, ensuring reliability and long-lasting performance. Our customer service team offers professional technical support to assist you with any questions or issues.
For support, please refer to the contact information provided with your purchase or visit the official FOTING website.

Figure 11: FOTING offers a 3-year warranty and dedicated customer support.