Fafeicy HT118A Digital Multimeter User Manual

Model: HT118A

1. Introduction

This manual provides detailed instructions for the safe and effective operation of your Fafeicy HT118A Digital Multimeter. The HT118A is an automatic range, multi-function voltage tester designed for electricians and general electrical parameter measurement. It offers reliable measurement data across a wide range of electrical parameters.

2. Safety Information

Always adhere to basic safety precautions when using this multimeter to prevent potential electric shock or personal injury, and to avoid damage to the meter or the equipment under test.

  • Read Instructions: Carefully read and understand all instructions in this manual before use.
  • Proper Use: Use the meter only as specified in this manual; otherwise, the protection provided by the meter may be impaired.
  • Voltage Limits: Do not apply more than the rated voltage, as marked on the meter, between the terminals or between any terminal and earth ground.
  • Test Leads: Inspect test leads for damaged insulation or exposed metal. Replace if damaged.
  • Battery Installation: Ensure batteries are correctly installed before operation.
  • Non-Contact Voltage Detection: Utilize the non-contact voltage detection feature to identify live circuits without direct contact, reducing the risk of electric shock.
  • Fuse Replacement: To avoid electrical shock, remove test leads before opening the case to replace the fuse. Install a fuse with the specified amp and volt rating.
Rear view of the Fafeicy HT118A Digital Multimeter showing the battery compartment and warning label.

Figure 1: Rear view of the multimeter with battery compartment and safety warning.

3. Product Overview

The Fafeicy HT118A Digital Multimeter is a robust tool designed for precise electrical measurements. It features an automatic ranging function, a clear digital display, and various measurement capabilities.

Fafeicy HT118A Digital Multimeter with its display showing '0.000' and the rotary dial set to OFF.

Figure 2: Front view of the Fafeicy HT118A Digital Multimeter.

3.1 Components

  • Digital Display: Shows measurement readings.
  • Rotary Switch: Selects measurement functions.
  • Function Buttons: Include HOLD, MAX/MIN, FUNC, and backlight control.
  • Input Jacks: For connecting test leads (COM, VΩHz, mA, 10A).
  • Test Leads: Red and black leads for making electrical connections.
  • Temperature Probe: For temperature measurements.
Fafeicy HT118A Digital Multimeter, test leads, and temperature probe laid out with the user manual.

Figure 3: Multimeter package contents including test leads and temperature probe.

3.2 Key Features

  • Automatic Ranging
  • Non-Contact Voltage (NCV) Detection
  • True RMS Measurement
  • Large LCD with Backlight
  • Data Hold Function
  • Max/Min Value Measurement
  • Flashlight
  • Low Battery Indication

4. Setup

4.1 Battery Installation

The HT118A requires two 1.5V AA batteries (not included) for operation.

  1. Ensure the multimeter is turned OFF and disconnect all test leads from the input jacks.
  2. Locate the battery compartment cover on the rear of the device.
  3. Use a screwdriver to open the battery compartment.
  4. Insert two 1.5V AA batteries, observing the correct polarity (+ and -).
  5. Replace the battery compartment cover and secure it with the screw.

4.2 Connecting Test Leads

Always connect the black test lead to the "COM" (common) input jack. Connect the red test lead to the appropriate input jack based on the measurement function:

  • VΩHz: For voltage, resistance, frequency, capacitance, and diode/continuity tests.
  • mA: For milliampere current measurements.
  • 10A: For high current (up to 10 Amperes) measurements.
Close-up of the Fafeicy HT118A Digital Multimeter's input jacks for test leads.

Figure 4: Input jacks for test leads.

5. Operating Instructions

Turn the rotary switch to the desired measurement function. The meter will automatically select the appropriate range.

5.1 DC/AC Voltage Measurement

  1. Connect the black test lead to the COM jack and the red test lead to the VΩHz jack.
  2. Turn the rotary switch to the V (DC Voltage) or V~ (AC Voltage) position.
  3. Touch the test probes to the circuit or component under test.
  4. Read the voltage value on the display.

5.2 DC/AC Current Measurement

  1. Important: Ensure the circuit is de-energized before connecting the meter in series.
  2. Connect the black test lead to the COM jack.
  3. For current up to 600mA, connect the red test lead to the mA jack. For current up to 10A, connect the red test lead to the 10A jack.
  4. Turn the rotary switch to the A (DC Current) or A~ (AC Current) position.
  5. Open the circuit where current is to be measured and connect the meter in series.
  6. Re-energize the circuit and read the current value on the display.

5.3 Resistance Measurement

  1. Connect the black test lead to the COM jack and the red test lead to the VΩHz jack.
  2. Turn the rotary switch to the Ω (Resistance) position.
  3. Ensure the circuit or component under test is de-energized.
  4. Touch the test probes across the component.
  5. Read the resistance value on the display.

5.4 Capacitance Measurement

  1. Connect the black test lead to the COM jack and the red test lead to the VΩHz jack.
  2. Turn the rotary switch to the F (Capacitance) position.
  3. Ensure the capacitor is fully discharged before testing.
  4. Touch the test probes across the capacitor terminals.
  5. Read the capacitance value on the display.

5.5 Frequency Measurement

  1. Connect the black test lead to the COM jack and the red test lead to the VΩHz jack.
  2. Turn the rotary switch to the Hz (Frequency) position.
  3. Touch the test probes to the circuit where frequency is to be measured.
  4. Read the frequency value on the display.

5.6 Non-Contact Voltage (NCV) Detection

  1. Turn the rotary switch to the NCV position.
  2. Move the top end of the multimeter close to the conductor or outlet.
  3. The meter will indicate the presence of AC voltage through an audible beep and visual indicator.
A hand holding the Fafeicy HT118A Digital Multimeter, with its kickstand extended, in front of an electrical panel.

Figure 5: Multimeter in use with its kickstand.

6. Maintenance

6.1 Cleaning

Wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents. Ensure the meter is completely dry before use.

6.2 Battery Replacement

When the low battery indicator appears on the display, replace the batteries as described in Section 4.1. Remove batteries if the meter is not used for an extended period.

6.3 Fuse Replacement

If the current measurement function fails, the fuse may need replacement. Refer to the safety warnings on the back of the device for fuse specifications (e.g., 600mA/250V and 10A/250V). Always replace with a fuse of the same type and rating.

7. Troubleshooting

  • No Display: Check battery installation and charge. Replace batteries if necessary.
  • Incorrect Readings: Ensure test leads are correctly connected to the appropriate input jacks and the rotary switch is set to the correct function. Verify the circuit or component under test is de-energized before resistance or capacitance tests.
  • Current Measurement Failure: Check the fuse. Replace if blown, ensuring the correct fuse type and rating.
  • NCV Not Detecting: Ensure the NCV function is selected and the meter is brought close enough to a live AC conductor.

8. Specifications

The following table details the measurement ranges and accuracy for the Fafeicy HT118A Digital Multimeter.

ItemRangeResolutionAccuracy
DC Voltage600mV0.1mV± (0.5% of reading + 3)
DC Voltage6V0.001V
DC Voltage60V0.01V
DC Voltage600V0.1V
DC Voltage1000V1V
AC Voltage6V0.001V±(0.8% of reading +5)
AC Voltage60V0.01V
AC Voltage600V0.1V
AC Voltage1000V1V
DC Current600µA0.1µA± (1.2% of reading + 3)
DC Current6000µA1µA
DC Current60mA0.01mA
DC Current600mA0.1mA
DC Current10A0.01A
AC Current60µA0.1µA± (1.5% of reading + 3)
AC Current600µA1µA
AC Current60mA0.01mA
AC Current600mA0.1mA
AC Current10A0.01A
Resistance600Ω0.1Ω±(1.0% of reading +3)
Resistance6kΩ0.001kΩ
Resistance60kΩ0.01kΩ
Resistance600kΩ0.1kΩ
Resistance6MΩ0.001MΩ±(1.5% of reading +3)
Resistance60MΩ0.01MΩ
Capacitance10nF0.001nF±(4.0% reading +5)
Capacitance100nF0.01nF
Capacitance1000nF0.1nF
Capacitance10µF0.001µF
Capacitance100µF0.01µF
Capacitance1000µF0.1µF
Capacitance10mF0.001mF±(5.0% of reading +5)
Capacitance100mF0.01mF
Frequency10Hz0.001Hz±(1.0% reading +3)
Frequency100Hz0.01Hz
Frequency1000Hz0.1Hz
Frequency10kHz0.001kHz
Frequency100kHz0.01kHz
Frequency1000kHz0.1kHz
Frequency10MHz0.001MHz± (3.0% of reading + 3)
Duty Cycle1~99%0.10%

General Specifications:

  • Item Model Number: Fafeicyo3cqx4yzp8
  • Battery: 2 x 1.5V AA (Not Included)
  • Material: ABS
  • Package Dimensions: 8.27 x 5.12 x 2.76 inches
  • Item Weight: 1.16 Pounds
  • Manufacturer: Fafeicy

9. Warranty and Support

For warranty information or technical support, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.