BOSEAN K-100A

Download PDF
Contents

BOSEAN K-100A O2 Gas Detector User Manual

Model: K-100A | Brand: BOSEAN

1. Introduction

The BOSEAN K-100A portable single gas detector is designed for continuous detection of oxygen (O2) gas. It features advanced MCU control, low power consumption, and provides reliable monitoring for worker safety in various industrial environments. This manual provides essential information for the safe and effective operation and maintenance of your gas detector.

BOSEAN K-100A O2 Gas Detector front view

Figure 1.1: Front view of the BOSEAN K-100A O2 Gas Detector, showing the display, buttons, and sensor area.

2. Safety Information

Always adhere to the following safety guidelines to ensure proper operation and prevent injury or damage:

  • Explosion-Proof Design: The device is designed to be explosion-proof, waterproof, and dustproof, making it suitable for hazardous environments. However, do not intentionally expose it to extreme conditions beyond its specifications.
  • Operating Environment: Use the detector within the specified working environment: Temperature -10 ℃ ~ 50 ℃, Humidity <95% RH.
  • Calibration: Regular calibration is crucial for accurate readings. Refer to the Maintenance section for calibration procedures.
  • Battery Safety: Use only the provided USB cable and charger for recharging. Do not attempt to open or replace the internal battery.
  • Maintenance: Any repairs or servicing should only be performed by qualified personnel.
BOSEAN K-100A O2 Gas Detector showing explosion-proof, waterproof, and dustproof features

Figure 2.1: The K-100A detector is built for safety, featuring explosion-proof, waterproof, and dustproof capabilities for robust performance in challenging environments.

3. Product Features

The BOSEAN K-100A O2 Gas Detector offers a range of features designed for reliable and user-friendly operation:

  • High Precision Sensor: Equipped with an electrochemical sensor for sensitive and accurate O2 gas detection, ensuring stability and repeatability.
  • Multiple Alarm Methods: Features adjustable audio, visual (light), and vibration alarms to alert users when preset gas levels are reached.
  • Long Battery Life: Integrated 1500mAh rechargeable battery provides over 14 hours of continuous working time.
  • Durable Construction: Made from high-quality ABS plastic and rubber, offering durability, fall resistance, and explosion-proof, waterproof, and dustproof properties.
  • Clear LCD Display: High-resolution LCD with backlight design for easy readability in various lighting conditions.
  • Portable Design: Compact size with a back clip for easy carrying and a portable aluminum alloy suitcase for transport and storage.
  • Advanced Functions: Includes adjustable low and high alarm levels, adjustable calibrating level, high concentration protection, self-test for the sensor, low battery indication, and self-adjustment function.
BOSEAN K-100A O2 Gas Detector with rapid response and precision sensors

Figure 3.1: The detector offers rapid response (0.5s) and reliable protection with precision O2 gas sensors.

BOSEAN K-100A O2 Gas Detector showing visual, audible, and tactile alarms

Figure 3.2: The device provides three types of alarms: visual, audible, and tactile (vibration) for comprehensive alert notification.

BOSEAN K-100A O2 Gas Detector highlighting 14-hour battery life

Figure 3.3: Enjoy extended operation with the 1500mAh battery, providing up to 14 hours of continuous use.

BOSEAN K-100A O2 Gas Detector with LCD backlight display

Figure 3.4: The LCD backlight design ensures the display is easy to read in various lighting conditions.

4. Package Contents

Upon opening the package, please verify that all the following items are included:

  • 1 x BOSEAN K-100A O2 Gas Detector
  • 1 x Calibration Cover
  • 1 x USB Cable
  • 1 x Charger
  • 1 x Portable Aluminum Alloy Suitcase
  • 1 x User Manual (this document)
  • 1 x Service Card
Contents of the BOSEAN K-100A O2 Gas Detector package

Figure 4.1: All items included in your purchase: the K-100A gas detector, calibration cap, portable aluminum alloy suitcase, charger, USB cable, user manual, and service card.

5. Setup

  1. Unpacking: Carefully remove all components from the packaging. Inspect the detector for any visible damage.
  2. Initial Charge: Before first use, fully charge the device. Connect the USB cable to the detector's charging port and the charger to a power outlet. The charging indicator will show the charging status. A full charge typically takes several hours.
  3. Power On: Press and hold the power button (usually the middle button) for a few seconds until the display illuminates and the device performs a self-test.
  4. Self-Test: The detector will perform an automatic self-test upon startup, checking its internal components and sensor. Ensure no error messages appear on the display.
  5. Time and Date (if applicable): If the device has a time/date setting, adjust it according to the instructions in the operating section.

6. Operating Instructions

6.1 Basic Operation

  • Power On/Off: Press and hold the power button to turn the device on or off.
  • Monitoring: Once powered on, the device will continuously monitor O2 gas levels and display the current concentration on the LCD screen.
  • Backlight: The LCD features a backlight for improved visibility. This may activate automatically or can be toggled via a dedicated button (refer to device specific button functions).

6.2 Alarm Functions

The detector is equipped with three types of alarms:

  • Audible Alarm: A loud beeping sound.
  • Visual Alarm: Flashing LED lights on the device.
  • Vibration Alarm: The device will vibrate.

These alarms will activate simultaneously when the detected O2 concentration exceeds the preset high alarm level or falls below the preset low alarm level. The alarm levels are adjustable.

6.3 Navigating Menus (if applicable)

The device typically has three buttons for navigation:

  • Left Button: Often used for "ESC" or "Menu" access.
  • Middle Button: Power On/Off, "OK" or "Enter" for selections.
  • Right Button: Often used for "Save" or "Up/Down" navigation.

Refer to the on-screen prompts and the detailed user interface guide (if provided separately) for specific menu navigation and setting adjustments, such as alarm thresholds or calibration levels.

7. Maintenance

7.1 Charging the Battery

When the low battery indication appears, recharge the device promptly using the provided USB cable and charger. The device can operate for over 14 hours on a full charge.

7.2 Cleaning

Wipe the exterior of the detector with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure the sensor opening is clear of dust and debris.

7.3 Calibration

Regular calibration is essential to maintain the accuracy of the gas detector. The frequency of calibration depends on usage, environmental conditions, and company policies, but a common recommendation is every 6-12 months, or if accuracy is suspected.

  1. Zero Calibration: This calibrates the sensor to a clean air environment (0 ppm for O2 in a non-oxygen environment, or 20.9% for O2 in fresh air). Follow the on-screen instructions for zero calibration.
  2. Span Calibration: This calibrates the sensor using a known concentration of O2 gas.
  3. Using the Calibration Cover: Attach the provided calibration cover to the sensor opening. Connect the calibration gas cylinder to the cover and follow the device's menu prompts for span calibration. This ensures accurate and stable calibration results.
BOSEAN K-100A O2 Gas Detector with calibration cover attached

Figure 7.1: The calibration cover is used to obtain more accurate and stable calibration results by providing a controlled gas environment to the sensor.

8. Troubleshooting

ProblemPossible CauseSolution
Device does not power on.Low or depleted battery.Charge the device fully.
Inaccurate readings.Needs calibration; sensor obstruction; sensor aging.Perform calibration. Clean sensor area. If issues persist, contact support for sensor replacement.
Alarm constantly active.High/low gas concentration in environment; alarm thresholds set too sensitively.Move to a clean air environment. Adjust alarm thresholds if necessary (refer to operating instructions).
Display is dim or unreadable.Backlight off; low battery.Activate backlight. Charge the device.

9. Specifications

ParameterValue
Model NumberK-100A
Detection GasOxygen (O2)
Detection Range0-1000ppm (Note: Product image shows 20.9 VOL% for O2, while description states 0-1000ppm. Please refer to device display for actual unit.)
Resolution1 PPM
Accuracy± 5% FS
Response Time≤ 30S
Alarm FunctionSound, Light, Vibration
Working Environment Temperature-10 ℃ ~ 50 ℃
Working Environment Humidity<95% RH (non-condensing)
Battery Capacity1500mAh
Battery Life>14 hours continuous operation
Charging MethodUSB Charging
MaterialABS + Rubber
Dimensions2.46 x 6.05 x 7.9 cm
Weight127 g

10. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the service card included in your package or contact BOSEAN customer support through the retailer where you purchased the product. Please have your model number (K-100A) and purchase date available when contacting support.

Note: If you need other types of gas detectors or have specific customization requests, please feel free to contact the manufacturer.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.