1. Introduction
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your NGDOLAOV Multi-Stage Vacuum Generator. Please read this manual thoroughly before using the product and retain it for future reference. These vacuum generators are designed for various industrial applications requiring reliable vacuum generation.
2. Safety Information
Always observe general safety precautions when working with pneumatic equipment. Ensure that the air supply is disconnected before performing any maintenance or installation. Use appropriate personal protective equipment (PPE). Do not exceed the maximum operating pressure or temperature specified for the unit. Ensure all connections are secure to prevent air leaks or accidental disconnections.
3. Product Overview and Dimensions
The NGDOLAOV Multi-Stage Vacuum Generator series offers various models (AM25L to AM150L) designed for efficient vacuum generation. Key components include the air supply inlet, vacuum port, exhaust port, and an integrated vacuum gauge for monitoring. An external silencer is also part of the assembly for noise reduction.

Figure 1: Overall dimensions and key specifications of the NGDOLAOV Multi-Stage Vacuum Generator. This image displays the generator with an external silencer, vacuum gauge, and various connection points. Dimensions are provided in millimeters: overall height 184mm, silencer height 119mm, width 193mm, main body height 45mm, and vacuum gauge height 64mm. Connection sizes are G1/8 (8.5mm) for the vacuum gauge and G1/4 (11mm) for the air supply. The image also indicates a working temperature range of -10 to 80 °C, a unit weight of 837g, and a maximum vacuum flow of 760 NL/min for the AM75L-AD-N model, which is part of the AM-Basic type (-92kPa) series.

Figure 2: Detailed technical drawings and dimensions for different NGDOLAOV vacuum generator models. This image includes three diagrams showing top, side, and front views of the vacuum generator, highlighting the air supply, vacuum, and exhaust ports. A table below provides specific 'H', 'H1', and 'L' dimensions for models AM25L-50L, AL25-50, AH40, AM75-100L, AL75-100, AH120, AM125-150L, and AL125-150. For example, AM75-100L has an 'H' dimension of 65 and an 'H1' dimension of 20.
4. Installation and Setup
Proper installation is crucial for optimal performance and longevity of the vacuum generator. Refer to the technical drawings for specific connection points and dimensions.
- Mounting: Securely mount the vacuum generator in a stable position, ensuring adequate space for connections and maintenance.
- Air Supply Connection: Connect a clean, dry, and regulated compressed air supply to the designated air inlet port (typically G1/4, 11mm). Ensure the air supply pressure is within the specified range for your model (refer to the 'Technical parameters' table).
- Vacuum Port Connection: Connect the vacuum line from your application to the vacuum port. The connection type and size will vary by model (e.g., G3/4, NPT3/4).
- Exhaust Port: The exhaust port, often equipped with a silencer, should be clear of obstructions.
- Vacuum Gauge: The integrated vacuum gauge (G1/8, 8.5mm) provides real-time vacuum level monitoring.
5. Operation
Once installed, the vacuum generator operates by converting compressed air into a vacuum. The performance characteristics vary by model and are detailed in the specifications tables.
- Initial Start-up: Gradually increase the air supply pressure to the recommended level. Observe the vacuum gauge to confirm vacuum generation.
- Monitoring: Regularly monitor the vacuum level via the integrated gauge.
- Shut-down: To stop operation, cut off the compressed air supply.
6. Specifications
The following tables provide detailed technical specifications for the NGDOLAOV Multi-Stage Vacuum Generators.

Figure 3: Parameter description, connection plate table, and technical parameters for NGDOLAOV vacuum generators. This image contains three tables:
- Parameter Description: Details series (AM, AL, AH), flow type, connection plate (A, B, D, E), sealing material (N-NBR, E-EPDM, F-Fluorine rubber), non-return valve options (Nil-Standard, A-With non-return valve), and control device options (Nil-Standard, PQ-Pneumatic control air supply, VD-Electric control vacuum breaking, VQ-Pneumatic control vacuum breaking, PVD-Electric control air supply + vacuum breaking, PVQ-Pneumatic control air supply + vacuum breaking, ES-Energy-saving system).
- Connection plate table 1: Specifies connection plate types (A, B, D, E) and corresponding air supply, vacuum (1), vacuum (2), and connection plate material for various models (AM, AL, AH) and flow ranges (25-100, 125-150, 40-120).
- Technical parameters: Lists models (AM25L to AM150L, AL25L to AL150L, AH40, AH120) with their air supply pressure (bar), max vacuum level (-kPa), max vacuum flow (NL/min), max air consumption (NL/min), noise level (dB(A)), recommended hose dia. (mm) for air supply and inner hose dia. (mm) for vacuum.
Vacuum Flow at Different Vacuum Levels

Figure 4: Vacuum flow (NL/min) at different vacuum levels (-kPa) for various NGDOLAOV models. This table provides detailed performance data, showing the vacuum flow rate for models AM25L through AM150L at air supply pressures of 3.4 bar and 6.0 bar, across vacuum levels ranging from 0 kPa to 90 kPa. For example, AM75L at 6.0 bar air supply has a vacuum flow of 700 NL/min at 0 kPa and 22 NL/min at 80 kPa.
General Product Specifications
- Package Dimensions: 0.39 x 0.39 x 0.39 inches
- Item Weight: 1.76 ounces
- Manufacturer: NGDOLAOV
- Assembly Required: No
- Number of Pieces: 1
7. Maintenance
Regular maintenance ensures the longevity and consistent performance of your vacuum generator.
- Air Quality: Ensure the compressed air supply is clean and dry. Contaminants can reduce efficiency and damage internal components.
- Filter Inspection: If an inline air filter is used, inspect and replace it regularly according to the filter manufacturer's recommendations.
- Leak Checks: Periodically check all pneumatic connections for leaks. Leaks can significantly reduce vacuum performance.
- Cleaning: Keep the exterior of the unit clean. Avoid using harsh chemicals that could damage the housing.
8. Troubleshooting
If you encounter issues with your vacuum generator, consider the following common troubleshooting steps:
- No Vacuum or Low Vacuum:
- Check air supply pressure: Ensure it meets the recommended range.
- Check for leaks: Inspect all vacuum and air supply connections.
- Verify air quality: Ensure the air supply is clean and dry.
- Check for obstructions: Ensure the exhaust port is clear.
- Excessive Noise:
- Ensure the silencer is properly installed and not damaged.
- Check for loose connections or mounting.
If problems persist after attempting these steps, please contact customer support.
9. Warranty and Support
For warranty information or technical support, please refer to the product packaging or contact your retailer. Keep your purchase receipt as proof of purchase. When contacting support, please have your product model number and purchase date available.