attwood 1733-4

Attwood Turbo 3000 Series In-Line Blower

Model: 1733-4 (3-inch)

Introduction

The Attwood Turbo 3000 Series 3-inch In-Line Blower is engineered to provide efficient and reliable ventilation for various marine applications. Designed for areas such as engine compartments, galleys, bilges, and heads, this blower ensures optimal airflow to reduce moisture and maintain air quality. Its compact design allows for installation in tight spaces, making it a versatile solution for boat owners.

This manual provides essential information for the proper setup, operation, and maintenance of your Attwood in-line blower. Please read all instructions carefully before installation and use to ensure safe and effective performance.

Product Features

Safety Information

Always prioritize safety during installation and operation. Failure to follow these guidelines may result in injury or damage to the product or vessel.

Setup and Installation

Before beginning installation, ensure you have all necessary materials and tools.

Materials Required for Installation:

Tools Required:

Installation Steps:

  1. Choose Mounting Location: Select a location that allows for proper airflow and is within reach of the necessary ducting and electrical connections. The built-in mounting feet allow for versatile vertical or horizontal installation.
  2. Secure the Blower: Use the two #10 pan head stainless steel screws to securely fasten the blower to the chosen surface via its mounting feet.
  3. Connect Ducting: Attach the 3-inch I.D. duct hose to both the inlet and outlet ports of the blower. Ensure a snug fit. Use the provided zip ties to secure the ducting to the blower ports, preventing air leaks and ensuring stability.
  4. Electrical Wiring: Connect the blower to a 12-volt DC power source. Install an in-line fuse holder with a 4-amp fuse on the positive wire. Connect the blower to an ON/OFF dash-mounted control switch. Use 16 gauge wire for connections and secure them with appropriate wire connectors. Ensure all connections are tight and protected from moisture.
  5. Test Operation: After installation, test the blower to ensure it operates correctly and provides adequate airflow.
Attwood 3-inch Turbo In-Line Blower, front view

Figure 1: Front view of the Attwood 3-inch Turbo In-Line Blower, showing the inlet and electrical wires.

Attwood 3-inch Turbo In-Line Blower, showing fan blades

Figure 2: View of the blower's outlet, highlighting the internal fan blades designed for maximum airflow.

Operating Instructions

Operating the Attwood in-line blower is straightforward:

  1. Power On: Locate the ON/OFF control switch installed on your dash or control panel. Flip the switch to the 'ON' position to activate the blower.
  2. Verify Operation: Listen for the sound of the blower operating and confirm airflow through the ventilation system.
  3. Power Off: To turn off the blower, flip the control switch to the 'OFF' position.

It is recommended to operate the blower for a few minutes before starting your engine, especially in enclosed engine compartments, to ensure any accumulated fumes are cleared.

Maintenance

Regular maintenance helps ensure the longevity and optimal performance of your Attwood in-line blower.

Troubleshooting

If you encounter issues with your Attwood in-line blower, refer to the following common troubleshooting steps:

ProblemPossible CauseSolution
Blower does not turn on.No power to the unit.
Blown fuse.
Faulty switch or wiring.
Check battery connections and voltage.
Inspect and replace the 4-amp fuse if blown.
Test the ON/OFF switch and wiring for continuity.
Low airflow.Obstructed inlet or outlet.
Kinked or damaged ducting.
Low voltage.
Clear any debris from the blower ports.
Inspect and repair/replace ducting.
Check battery voltage and wiring for proper supply.
Unusual noise during operation.Debris in the fan.
Loose mounting.
Worn motor.
Disconnect power and carefully inspect the fan for foreign objects. Remove if found.
Ensure the blower is securely mounted.
If noise persists and is significant, the motor may be failing and require replacement.

Specifications

SpecificationValue
BrandAttwood
Model NameIn-Line Bilge Blower
Part Number1733-4
Size3 inches (I.D.)
Voltage12 Volts (DC)
Amp Draw @ 13.6V2.6 Amps
Amp Draw @ 12.0V4 Amps
Output (Open Flow) @ 13.6V145 CFM
Output (Open Flow) @ 12.0V120 CFM
Item Weight386 Grams
ColorWhite
MaterialPlastic
Product Dimensions (LxWxH)11.25"D x 11.5"W x 5.75"H
Mounting TypeVersatile (Vertical/Horizontal)
Engine TypeElectric
Recommended UsesHeads, Engine Compartments, Bilges, Where moisture is present
UPC022697173348
OEM Part NumberATT17334
Attwood 3-inch Turbo In-Line Blower packaging with specifications

Figure 3: Product packaging displaying key features and specifications.

Warranty and Support

The Attwood 1733-4 Turbo 3000 Series 3-inch In-Line Blower comes with a 3-Year Limited Warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use.

For warranty claims, technical support, or further assistance, please contact Attwood customer service. Keep your proof of purchase for warranty validation.

For the most up-to-date contact information and support resources, please visit the official Attwood website or refer to the contact details provided with your product packaging.

Related Documents - 1733-4

PreviewAttwood Ultimate Rechargeable Fan - Instruction Manual and Safety Guide
Comprehensive instruction sheet for the Attwood Ultimate Rechargeable Fan, including setup, operation, safety warnings, care instructions, and battery cautions. Model #9040-4.
PreviewAttwood T500 Recirq Livewell Aerator Kit Installation Instructions
This document provides installation instructions for the Attwood T500 Recirq Livewell Aerator Kit, model 4253. It covers features, warnings, required materials, mounting location selection, pump and aerator head installation, hose installation, wiring instructions, and care and maintenance.
PreviewAttwood Sahara Mk2 Automatic Bilge Pumps Installation and Operation Guide
Comprehensive guide for Attwood Sahara Mk2 automatic bilge pumps (Models S500, S800, S1200). Includes safety warnings, installation instructions, wiring diagrams, performance specifications, and warranty information.
PreviewAttwood PowerBase Antenna Installation Guide
Installation guide for the Attwood PowerBase Antenna, a powered fold-down antenna base. Includes required installation parts and compatibility information.
PreviewAttwood PowerBase 6100 Series Powered Fold-Down Light and Antenna Base Installation Manual
Comprehensive installation, wiring, maintenance, and troubleshooting guide for the Attwood PowerBase 6100 Series, a powered fold-down light and antenna base for marine applications.
PreviewAttwood PowerBase 6100 Series Powered Fold-Down Light and Antenna Base Installation Manual
This manual provides detailed instructions for the installation of the Attwood PowerBase 6100 Series Powered Fold-Down Light and Antenna Base. It covers mounting location, wiring, installation of lights and antennas, testing, maintenance, and warranty information.