Aux ASW32-12A3INV/SS

Aux ASW32-12A3INV/SS Inverter Air Conditioner User Manual

Model: ASW32-12A3INV/SS

1. Introduction

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Aux ASW32-12A3INV/SS Inverter Air Conditioner. Please read this manual thoroughly before using the appliance and keep it for future reference. Proper understanding of these instructions will ensure optimal performance and extend the lifespan of your unit.

2. Safety Information

Your safety and the safety of others are paramount. Please observe all safety warnings and precautions outlined in this section.

  • Electrical Safety: Ensure the power supply matches the unit's requirements (115V). Do not use damaged power cords or plugs. Always disconnect power before cleaning or servicing.
  • Installation: Installation must be performed by qualified personnel in accordance with local electrical and safety codes. Improper installation can lead to electric shock, fire, or water leakage.
  • Operation: Do not insert fingers or objects into the air inlet/outlet. Do not operate the unit with wet hands. Keep children away from the unit.
  • Maintenance: Only qualified service technicians should perform repairs. Do not attempt to repair the unit yourself.
  • Refrigerant: This unit contains refrigerant. Handle with care and ensure proper disposal according to environmental regulations.

3. Product Overview

The Aux ASW32-12A3INV/SS is a 1-ton capacity, 115V Inverter Split Type Air Conditioner designed for cooling only. It consists of an indoor unit and an outdoor unit, connected by refrigerant lines and electrical wiring.

Indoor Unit

The indoor unit is responsible for circulating cooled air within the room. It houses the evaporator coil, fan, and control electronics.

Aux ASW32-12A3INV/SS Inverter Air Conditioner Indoor Unit

Figure 1: Aux ASW32-12A3INV/SS Inverter Air Conditioner Indoor Unit. This image displays the white indoor unit of the Aux ASW32-12A3INV/SS Inverter Air Conditioner. The unit features a sleek, rectangular design with rounded edges and the 'AUX' logo centered on the front panel. The air outlet louvers are visible at the bottom.

Main Components:

  • Indoor Unit: Mounted inside the room, it discharges conditioned air.
  • Outdoor Unit: Placed outside, it dissipates heat from the room.
  • Remote Control: Used to operate the air conditioner functions.
  • Air Filter: Located inside the indoor unit, it cleans the air.

4. Setup and Installation

Installation of this split-type air conditioner requires specialized tools and knowledge. It is strongly recommended that installation be performed by a certified HVAC technician to ensure proper functioning, safety, and warranty validity.

Key Installation Considerations:

  • Location: Choose a location for the indoor unit that allows for even air distribution and easy access for maintenance. The outdoor unit should be placed in a well-ventilated area, away from direct sunlight or obstructions.
  • Mounting: Securely mount both indoor and outdoor units according to manufacturer guidelines and local building codes.
  • Refrigerant Piping: Proper sizing and insulation of refrigerant lines are crucial for efficiency. Avoid kinks or sharp bends.
  • Drainage: Ensure proper drainage for condensate water from the indoor unit to prevent leaks.
  • Electrical Connection: Connect the unit to a dedicated 115V power supply circuit with appropriate circuit protection. Verify all wiring connections are secure and correct.
  • Vacuuming and Leak Test: The refrigerant system must be thoroughly vacuumed to remove air and moisture, and then tested for leaks before charging.

5. Operating Instructions

Your Aux ASW32-12A3INV/SS air conditioner is designed for user-friendly operation via its remote control.

Remote Control Functions:

  • Power Button: Press to turn the unit ON or OFF.
  • Mode Button: Select the desired operating mode. This model primarily offers a Cooling (Solo Frío) mode.
  • Temperature Adjustment Buttons (▲/▼): Increase or decrease the set temperature.
  • Fan Speed Button: Adjust the fan speed (Auto, Low, Medium, High).
  • Swing Button: Activates or deactivates the automatic vertical louver swing for better air distribution.
  • Timer Button: Set the unit to turn ON or OFF automatically after a specified period.

Basic Operation Steps:

  1. Ensure the unit is properly connected to power.
  2. Point the remote control towards the indoor unit and press the Power button.
  3. Press the Mode button to select the Cooling mode.
  4. Use the Temperature Adjustment buttons to set your desired room temperature. A comfortable range is typically between 22-26°C (72-79°F).
  5. Adjust the Fan Speed and Swing functions as desired for optimal comfort.

6. Maintenance

Regular maintenance ensures the efficiency and longevity of your air conditioner. Always disconnect power before performing any maintenance.

Air Filter Cleaning:

  • Frequency: Clean the air filters every two weeks, or more frequently if the unit is used heavily or in dusty environments.
  • Steps:
    1. Open the front panel of the indoor unit.
    2. Carefully remove the air filters.
    3. Wash the filters with lukewarm water and a mild detergent. Rinse thoroughly.
    4. Allow the filters to dry completely in a shaded area before reinstalling them. Do not expose to direct sunlight.
    5. Reinstall the dry filters and close the front panel.

General Cleaning:

  • Wipe the indoor and outdoor unit surfaces with a soft, damp cloth. Do not use harsh chemicals, abrasives, or solvents.
  • Keep the outdoor unit clear of debris, leaves, and other obstructions to ensure proper airflow.

Seasonal Maintenance:

  • At the beginning of the cooling season, check for any unusual noises or odors.
  • Consider a professional inspection and cleaning of the coils and drainage system annually.

7. Troubleshooting

Before contacting customer service, please refer to the following table for common issues and their potential solutions.

ProblemPossible CauseSolution
Unit does not startNo power supply; Remote control batteries low; Timer function activeCheck power connection and circuit breaker; Replace remote control batteries; Cancel timer setting
Insufficient coolingDirty air filters; Blocked air intake/outlet; Room too large; Doors/windows open; Temperature setting too highClean air filters; Remove obstructions; Close doors/windows; Lower temperature setting
Unusual noiseLoose parts; Obstruction in fan; Unit not levelCheck for loose components; Remove obstructions; Ensure unit is level. If noise persists, contact service.
Water leakage from indoor unitClogged drain pipe; Improper installationClear drain pipe; Contact a qualified technician for inspection.

If the problem persists after attempting these solutions, please contact a qualified service technician.

8. Specifications

Detailed technical specifications for the Aux ASW32-12A3INV/SS Inverter Air Conditioner.

FeatureSpecification
BrandAux
Model NumberASW32-12A3INV/SS
ColorWhite
Product Dimensions (Indoor Unit)29 cm (Depth) x 77.7 cm (Width) x 49.8 cm (Height)
Capacity1 Ton (12,000 BTU)
Power1000 Watts
Voltage115 Volts
Annual Energy Consumption700 Kilowatt Hours
Noise Level53 dB
Product Weight (Indoor Unit)8.21 Kilograms
Controller TypeRemote Control
BEE Rating1 Star

9. Warranty and Support

For warranty information, please refer to the warranty card included with your product or contact your authorized Aux dealer. Keep your purchase receipt as proof of purchase for warranty claims.

For technical support, service, or spare parts, please contact your local Aux service center or the retailer from whom you purchased the unit. Provide your model number (ASW32-12A3INV/SS) and serial number (if applicable) when seeking assistance.

Related Documents - ASW32-12A3INV/SS

Preview AUX T/121E Split Type Air Conditioner Operation Manual
This operation manual provides detailed instructions for the AUX T/121E Split Type Air Conditioner, covering safety precautions, preparation, operation modes, fan speed and airflow adjustment, timer functions, special features, care and cleaning, troubleshooting, and disposal.
Preview AUX Console Air Conditioner Installation Operation Instruction Manual
This manual provides detailed instructions for the installation, operation, and maintenance of AUX Console air conditioners. It covers safety precautions, installation steps, electrical connections, fault diagnosis, and service procedures for split-type ODU models.
Preview AUX A-THERMAL Split-Type Heat Pump Wired Controller Manual
User manual for the AUX A-THERMAL split-type heat pump wired controller, detailing installation, operation, functions, and settings for optimal climate control.
Preview Manuel d'Installation et d'Utilisation du Climatiseur Split AUX
Guide complet pour l'installation, la configuration, l'utilisation et l'entretien de votre climatiseur split AUX. Inclut des instructions de sécurité, des conseils de dépannage et des informations sur la garantie.
Preview AUX Split Type Wall Mounted Air Conditioner Owner's Manual
Comprehensive owner's manual for AUX split-type wall-mounted air conditioners, covering operation, maintenance, safety precautions, and troubleshooting. Learn how to properly install, use, and care for your AUX air conditioner.
Preview AUX Split Air Conditioner Installation and Operation Manual
This manual provides comprehensive instructions for the installation, operation, and safety precautions for AUX Split Air Conditioners. It covers indoor and outdoor unit installation, electrical connections, refrigerant handling, and testing procedures.