1. Important Safety Information
Please read all instructions carefully before operating the dehumidifier. Retain this manual for future reference.
Electrical Safety
- Ensure the power supply matches the voltage requirements specified on the unit's rating label.
- Always plug the unit into a grounded electrical outlet. Do not use extension cords or adapter plugs.
- Do not operate the dehumidifier with a damaged power cord or plug. If damaged, contact qualified service personnel.
- Never touch the power plug with wet hands.
General Operation Safety
- This appliance is for indoor use only. Do not use outdoors.
- Maintain a minimum clearance of 12 inches (30 cm) around the unit for proper airflow.
- Do not insert objects into the air inlet or outlet.
- Keep the unit away from heat sources, flammable materials, and direct sunlight.
- Always turn off and unplug the unit before cleaning or performing any maintenance.
- Do not allow children to play with or around the dehumidifier.
2. Product Overview
The Waykar 125 Pint Crawl Space Dehumidifier is designed for efficient moisture removal in large areas up to 6,500 square feet, featuring a robust metal construction and advanced humidity control.
Key Features
- High Capacity: Removes up to 125 pints of moisture per day (at 95°F, 90% RH).
- Wide Coverage: Suitable for spaces up to 6,500 sq. ft.
- Adjustable Humidity: Range of 10%-98% Relative Humidity (RH).
- Rotary Compressor: High-efficiency design for improved energy savings and lifespan.
- Dual Drainage Options: Includes a 16.4 ft pump drainage hose for vertical drainage and a 6.6 ft gravity drainage hose.
- Duct Mount Supported: Can be integrated into existing HVAC systems (venting hoses not included).
- Heavy-Duty Construction: High-strength metal casing for durability.
- Auto Defrost: Prevents frost buildup on coils, maintaining efficiency.
- Power-Off Memory: Restores previous settings after a power interruption.
- Washable Filter: Easy to clean and reuse, with a cleaning reminder function.
Unit Components
Familiarize yourself with the main parts of your dehumidifier:

Image Description: Front view of the Waykar 125 Pint Crawl Space Dehumidifier, showing the control panel on the left, the main white casing, and the air outlet on the right. A coiled clear drainage hose is visible in the foreground.

Image Description: Close-up of the dehumidifier's control panel on the left, displaying digital readings and control buttons. The side of the unit with the air outlet is also visible.
- Control Panel: Digital display and buttons for setting humidity, timer, and other functions.
- Air Inlet: Located on the back/side, where humid air enters.
- Air Outlet: Located on the front/side, where dry air is expelled.
- Drainage Ports: Connections for the pump drainage hose and gravity drainage hose.
- Washable Filter: Removable filter for air purification and maintenance.
- Heavy-Duty Handles: Two handles on top for easy transport.
- Adjustable Leveling Feet: For stable placement on uneven surfaces.
3. Setup
Unpacking
- Carefully remove the dehumidifier from its packaging.
- Remove all packing materials, including any tape or protective films.
- Inspect the unit for any signs of damage during transit. If damaged, do not operate and contact customer support.
Placement
Proper placement is crucial for efficient operation and safety.
- Place the dehumidifier on a firm, level surface capable of supporting its weight.
- Ensure there is at least 12 inches (30 cm) of clearance around all sides of the unit for adequate airflow.
- Avoid placing the unit in direct sunlight or near heat-generating appliances.
- For crawl spaces or basements, ensure the unit is elevated slightly off the ground to prevent contact with standing water, if applicable. The adjustable leveling feet can assist with this.

Image Description: The Waykar dehumidifier positioned in a crawl space, demonstrating typical installation under a raised floor. The unit is placed on blocks for elevation.
Drainage Options
The unit offers two methods for continuous drainage:

Image Description: A visual representation illustrating the two drainage options: a pump drain hose extending upwards for vertical drainage and a gravity drain hose extending downwards for horizontal drainage.
A. Pump Drainage (16.4 ft hose included)
- Connect the provided 16.4 ft pump drainage hose to the pump outlet port on the unit.
- Route the hose to a suitable drain location, ensuring it is free of kinks or obstructions. The built-in pump can lift water vertically up to 16.4 ft.
- This option is ideal for draining water to a sink, floor drain, or outside, especially when the drain is higher than the dehumidifier.
B. Gravity Drainage (6.6 ft hose included)
- Connect the provided 6.6 ft gravity drainage hose to the gravity drain outlet port on the unit.
- Ensure the hose is sloped downwards continuously from the unit to the drain point to allow water to flow by gravity.
- This option is suitable when the drain is lower than the dehumidifier.
4. Operating Instructions
Control Panel Functions

Image Description: The control panel of the dehumidifier, highlighting the digital display and various buttons for power, humidity settings, timer, and filter reminder.
- Power Button: Turns the unit ON or OFF.
- Humidity Setting Buttons (Up/Down Arrows): Adjusts the desired humidity level from 10% to 98% RH.
- Timer Button: Sets the auto-on or auto-off timer (0-24 hours).
- Fan Speed Button: Adjusts fan speed (High/Low).
- Display Screen: Shows current humidity, set humidity, timer settings, and error codes.
- Filter Reminder Indicator: Illuminates when the filter needs cleaning.
Initial Operation
- Plug the power cord into a grounded electrical outlet.
- Press the Power button to turn on the unit. The display will show the current room humidity.
- Use the Up/Down arrows to set your desired humidity level. A common comfortable range is 45%-55% RH. The unit will operate until the set humidity is reached, then cycle off. It will restart when the humidity rises above the set level.
Continuous Operation
To run the dehumidifier continuously regardless of humidity level, set the target humidity to the lowest possible setting (e.g., 10% RH). The unit will then run continuously, provided the temperature is within its operating range and the drainage system is functioning.
Optional Remote Control
A wired remote control (sold separately) can be connected to the unit for convenient long-distance control, allowing you to adjust settings without directly accessing the dehumidifier, which is particularly useful in crawl spaces or hard-to-reach areas.

Image Description: An image showing the optional wired remote control panel mounted on a wall, with a hand interacting with its display. The dehumidifier is visible in the background, indicating remote operation.
5. Maintenance
Regular maintenance ensures optimal performance and extends the lifespan of your dehumidifier.
Filter Cleaning
The washable filter should be cleaned regularly, typically every two weeks or when the filter reminder indicator illuminates.

Image Description: A diagram illustrating the location of the washable filter on the dehumidifier, along with the unit's overall dimensions. A separate inset shows the filter being cleaned under running water.
- Turn off the unit and unplug it from the power outlet.
- Locate the filter access panel (usually on the side or back) and remove the filter.
- Rinse the filter under warm, running water. For stubborn dirt, use a mild detergent.
- Allow the filter to air dry completely before reinstalling it. Do not use a dryer or direct heat.
- Reinsert the dry filter into the unit and close the access panel.
- Plug in the unit and press the filter reset button (if available) or power cycle the unit to clear the reminder.
Unit Cleaning
- Wipe the exterior of the unit with a soft, damp cloth. Do not use harsh chemicals or abrasive cleaners.
- Clean the air inlet and outlet grilles with a vacuum cleaner or soft brush to remove dust and debris.
Storage
If storing the unit for an extended period:
- Turn off and unplug the unit.
- Ensure all water has drained from the unit and hoses.
- Clean the filter and the exterior of the unit.
- Coil the power cord and drainage hoses neatly.
- Store the unit in a cool, dry place, away from direct sunlight and extreme temperatures.
6. Troubleshooting
Before contacting customer support, please refer to the following troubleshooting guide for common issues.
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not turn on. | No power supply; Power cord loose; Unit is in standby mode. | Check power outlet and circuit breaker; Ensure power cord is securely plugged in; Press the Power button. |
| Unit is running but not dehumidifying. | Air filter clogged; Room temperature too low; Humidity setting too high; Doors/windows open. | Clean the air filter; Ensure room temperature is above 41°F (5°C); Lower the humidity setting; Close all doors and windows. |
| Water leakage. | Drainage hose kinked or blocked; Hose not properly connected; Unit not level. | Check and clear any kinks or blockages in the hose; Ensure hose is securely connected to the drain port; Adjust leveling feet to ensure the unit is stable and level. |
| Unit is noisy. | Unit not level; Air filter clogged; Fan obstruction. | Ensure unit is on a flat, stable surface; Clean the air filter; Check for any obstructions in the fan area. |
| Pump not draining water. | Pump hose kinked or blocked; Pump malfunction; Water level not high enough to activate pump. | Verify pump hose is clear and properly routed; Ensure the unit has accumulated enough water for the pump to activate; If issue persists, contact customer support. |
7. Specifications
| Specification | Detail |
|---|---|
| Model Number | AFW2.0DPM |
| Moisture Removal Capacity | 125 Pints/Day (95°F, 90% RH) |
| Coverage Area | Up to 6500 Square Feet |
| Product Dimensions (DxWxH) | 19.29" x 13.58" x 12.6" |
| Item Weight | 49.8 Pounds |
| Humidity Setting Range | 10% - 98% RH |
| Airflow (CFM) | 300 CFM |
| Drainage Options | Built-in Pump (16.4 ft hose), Gravity Drain (6.6 ft hose) |
| Special Features | Automatic Defrost, Automatic Moisture Removal, Automatic Restart, Built-In Pump, Overheat Protection, Washable Filter |
| Color | White |
8. Warranty and Support
Waykar provides a 5-Year Quality Coverage for this dehumidifier, demonstrating commitment to product reliability and customer satisfaction.
For technical assistance, warranty claims, or any questions regarding your Waykar dehumidifier, please refer to the contact information provided on the product packaging or the official Waykar website. When contacting support, please have your model number (AFW2.0DPM) and purchase details ready.