Bayrol 287304

BAYROL Electronic Pooltester II Refill Tablets User Manual

Model: 287304

1. Product Overview

This manual provides essential information for the safe and effective use of the BAYROL Electronic Pooltester II Refill Tablets. These tablets are designed for precise water analysis in swimming pools, ensuring optimal water quality and safety.

BAYROL Electronic Pooltester II Refill Tablets packaging

Image 1: Packaging of BAYROL Electronic Pooltester II Refill Tablets. The box displays the brand "BAYROL", product name "REFILL ELECTRONIC POOLTESTER II ANALYSIS TABLETS", and lists the contents: 20 x Phenol red, 20 x DPD N°1, 10 x DPD N°3, 10 x CYA-Test, and 10 x Alkalinity-M tablets. It also indicates compatibility with Electronic Pooltester I.

2. Safety Information

  • Keep out of reach of children and pets.
  • Do not ingest the tablets. In case of ingestion, seek immediate medical attention.
  • Avoid contact with skin and eyes. If contact occurs, rinse thoroughly with water.
  • Store in a cool, dry place, away from direct sunlight and moisture.
  • Use only with the BAYROL Electronic Pooltester II or compatible devices as indicated.
  • Dispose of used tablets and packaging according to local regulations.

3. Package Contents

Each refill pack for the BAYROL Electronic Pooltester II (Model 287304) contains the following analysis tablets:

  • 20 x DPD N°1 Tablets (for Free Chlorine measurement)
  • 10 x DPD N°3 Tablets (for Total Chlorine measurement)
  • 20 x Phenol Red Tablets (for pH measurement)
  • 10 x CyA Test Tablets (for Cyanuric Acid measurement)
  • 10 x Alka-M Tablets (for Alkalinity measurement)

Note: The electronic pooltester device is sold separately.

4. Usage Instructions (Operating)

These tablets are designed for use with the BAYROL Electronic Pooltester II. Refer to your pooltester's specific manual for detailed operating instructions. General steps for tablet use are as follows:

  1. Prepare the Pooltester: Ensure your BAYROL Electronic Pooltester II is clean and ready for use. Fill the sample chamber(s) with pool water according to the device's instructions.
  2. Add the Tablet: Carefully open the foil packaging of the required tablet (e.g., DPD N°1 for free chlorine, Phenol Red for pH). Avoid touching the tablet with your fingers as this can affect results. Drop one tablet into the designated sample chamber.
  3. Dissolve the Tablet: Close the chamber and gently shake or stir the pooltester until the tablet is completely dissolved. This may take a few moments.
  4. Read the Result: Place the pooltester into the device and follow its instructions to obtain the measurement. The device will display the result for the specific parameter being tested.
  5. Record and Adjust: Record your readings and compare them to recommended pool water parameters. Adjust your pool chemistry as needed based on the results.
  6. Clean After Use: Thoroughly rinse the sample chamber(s) and cap(s) with clean water after each test to prevent contamination for future readings.

Recommended pH Range:

For optimal pool water balance, the recommended pH range is 7.2-7.6.

5. Maintenance and Storage

Storage:

  • Store tablets in their original, sealed foil packaging until ready for use.
  • Keep in a cool, dry place, ideally between 5°C and 25°C (41°F and 77°F).
  • Protect from direct sunlight, heat, and moisture.
  • Do not store near chemicals that could contaminate the tablets.

Maintenance:

The tablets themselves require no maintenance. Ensure the electronic pooltester device is regularly cleaned and maintained according to its own manual to ensure accurate readings.

6. Troubleshooting

If you encounter issues with your water analysis results, consider the following:

  • Inaccurate Readings:
    • Ensure tablets are not expired.
    • Verify tablets were not touched by bare hands.
    • Check if the pooltester device is clean and calibrated.
    • Ensure the tablet fully dissolved in the water sample.
  • Tablet Not Dissolving:
    • Ensure sufficient shaking or stirring.
    • Check water temperature; extremely cold water may slow dissolution.

For issues related to the electronic pooltester device itself, refer to its dedicated user manual or contact BAYROL customer support.

7. Specifications

AttributeValue
Product NameBAYROL Electronic Pooltester II Refill Tablets
Model Number287304
BrandBayrol
Contents20 x DPD N°1, 10 x DPD N°3, 20 x Phenol Red, 10 x CyA Test, 10 x Alka-M
Total Units70 tablets
Recommended pH Range7.2-7.6
Recommended UsePool water analysis
ManufacturerBAYROL
Package Dimensions10 x 8 x 5 cm
Package Weight500 grams

8. Disposal

Dispose of empty packaging and expired or unused tablets in accordance with local environmental regulations. Do not flush down drains or dispose of in household waste if local regulations prohibit it.

9. Customer Support

For further assistance, questions regarding product use, or technical support, please contact BAYROL customer service. Refer to the official BAYROL website for contact information.

Please have your product model number (287304) and purchase details ready when contacting support.

© 2025 BAYROL. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.