1. Introduction and Overview
The Green Cell PowerCore UPS (Uninterruptible Power Supply) is designed to provide reliable backup power and protect your electronic devices from power outages, voltage fluctuations, and surges. This model, with a capacity of 1500VA/1000W, features a pure sine wave output, an intuitive LCD display, and requires an external 12V DC battery for operation. It is ideal for home networks, office equipment, security systems, and sensitive electronics requiring stable power.
2. Safety Instructions
Please read and follow these safety instructions carefully before installing or operating the UPS. Failure to do so may result in electric shock, fire, or serious injury.
- External Battery Requirement: This UPS requires an external 12V DC battery (not included) to function. Do not attempt to operate the unit without a properly connected external battery.
- Qualified Personnel: The UPS contains hazardous voltages. Repairs should only be performed by authorized service personnel. Any attempt to open or repair the unit by an unqualified user could be dangerous.
- Ventilation: Ensure adequate ventilation around the UPS. Do not block ventilation openings. Maintain a minimum clearance of 10 cm (4 inches) on all sides.
- Environment: Install the UPS in a clean, dry, and temperature-controlled indoor environment. Avoid direct sunlight, heat sources, and areas with excessive dust or humidity.
- Liquid Contact: Do not expose the UPS to rain, water, or any other liquids. Do not place containers with liquids on or near the unit.
- Grounding: Always connect the UPS to a grounded power outlet.
- Overload: Do not overload the UPS. Ensure the total power consumption of connected devices does not exceed the UPS's rated capacity (1000W).
- Emergency Disconnect: In an emergency, disconnect the UPS from the mains power supply and disconnect the external battery immediately.
3. Product Overview
Familiarize yourself with the components of your Green Cell PowerCore UPS.
Front Panel

Figure 3.1: Front Panel with LCD Display
The front panel features an intuitive LCD display that provides real-time information on the UPS status, including input/output voltage, load level, and battery capacity. It also includes a power button and a mute button for alarms.
Rear Panel

Figure 3.2: Rear Panel Connectors
The rear panel provides all necessary connection points:
- AC Input: For connecting the UPS to the mains power supply.
- Schuko Outlets (2x): For connecting your devices to be protected.
- DC Battery Terminals (+/-): For connecting the external 12V DC battery.
- Charging Current Switch (L/M/H): Allows adjustment of the battery charging current.
- Circuit Breaker: Provides overload protection.
- Cooling Fan: Ensures proper heat dissipation.
Component Diagram

Figure 3.3: Labeled Components (1. Charger, 2. Display, 3. Audible Alarm Switch, 4. Sockets, 5. Removable Fuse, 6. DC Cables)
4. Setup
Follow these steps to set up your Green Cell PowerCore UPS.
- Unpack the UPS: Carefully remove the UPS from its packaging. Inspect for any damage.
- Placement: Place the UPS on a stable, flat surface in a well-ventilated area, away from direct sunlight, heat, and moisture. Ensure sufficient clearance for airflow.
- Connect External Battery:

Figure 4.1: UPS with External Battery Connection
Connect a 12V DC external battery (AGM type recommended) to the DC battery terminals on the rear panel. Ensure correct polarity: connect the red cable to the positive (+) terminal and the black cable to the negative (-) terminal. This connection is mandatory for the UPS to operate.
- Set Charging Current: Adjust the 'CHARGING CURRENT' switch on the rear panel to match the capacity of your external battery. Refer to your battery's specifications for the appropriate charging current (Low/Medium/High).
- Connect to Mains Power: Plug the UPS's AC input cable into a grounded wall outlet.
- Connect Devices: Plug your electronic devices (e.g., computer, monitor, router) into the Schuko output sockets on the rear panel of the UPS. Do not exceed the UPS's maximum load capacity of 1000W.
5. Operating Instructions
Powering On/Off
- To Power On: Press and hold the power button on the front panel for approximately 3 seconds until the LCD display illuminates and the UPS emits a short beep.
- To Power Off: Press and hold the power button for approximately 3 seconds until the LCD display turns off.
Understanding the LCD Display
The LCD display provides critical information about the UPS status:
- Input Voltage: Shows the current voltage from the mains power supply.
- Output Voltage: Displays the voltage supplied by the UPS to connected devices.
- Load Level: Indicates the percentage of the UPS's capacity being used by connected devices.
- Battery Capacity: Shows the charge level of the external battery.
- Status Indicators: Icons may light up to indicate utility mode, battery mode, overload, or other warnings.
Mute Function
During a power outage or certain alarm conditions, the UPS may emit an audible alarm. Press the mute button on the front panel to silence the alarm temporarily.
Pure Sine Wave Output
The Green Cell PowerCore UPS provides a pure sine wave output, which is identical to the power supplied by the utility grid. This ensures compatibility and safe operation for sensitive electronics such as PCs, servers, refrigerators, and heating systems, preventing damage or malfunctions caused by unstable voltage.
6. Maintenance
Proper maintenance ensures the longevity and reliable performance of your UPS.
- Battery Care: Since an external battery is used, regularly check its connections for corrosion and ensure they are secure. Follow the battery manufacturer's guidelines for maintenance and replacement.
- Cleaning: Keep the UPS clean and free of dust. Use a soft, dry cloth to wipe the exterior. Do not use liquid cleaners or solvents. Ensure ventilation openings are clear.
- Regular Checks: Periodically test the UPS by disconnecting it from the mains power to ensure it switches to battery mode correctly and provides backup power.
- Fuse Replacement: If the UPS has a user-serviceable fuse (refer to Figure 3.3, item 5), ensure to replace it with a fuse of the exact same type and rating if it blows. Always disconnect the UPS from all power sources before attempting fuse replacement.
7. Troubleshooting
If you encounter issues with your UPS, refer to the following common problems and solutions.
| Problem | Possible Cause | Solution |
|---|---|---|
| UPS does not power on | No external battery connected or battery discharged. | Ensure a 12V external battery is correctly connected and charged. |
| No backup power during outage | External battery not connected, faulty, or fully discharged. | Check battery connections. Test or replace the external battery. |
| Overload alarm / UPS shuts down | Too many devices connected, exceeding 1000W capacity. | Disconnect non-essential devices. Reduce the total load. |
| Battery not charging | Mains power issue, incorrect charging current setting, or faulty battery. | Check mains power. Verify charging current switch setting. Inspect or replace battery. |
| UPS emits continuous beeping | Low battery, overload, or other fault. | Check LCD display for specific error codes. Address the underlying issue (e.g., reduce load, charge battery). Press mute button to silence. |
| Circuit breaker tripped | Overload or short circuit. | Disconnect devices, reset the circuit breaker on the rear panel. Reconnect devices one by one to identify the faulty one. |
If the problem persists after attempting these solutions, please contact Green Cell customer support for further assistance.
8. Specifications
Detailed technical specifications for the Green Cell PowerCore UPS 1500VA 1000W.
| Feature | Specification |
|---|---|
| Brand | Green Cell |
| Model Number | UPSLPPC1000 |
| Power Capacity | 1000 W / 1500 VA |
| Input Voltage | 230 Volts AC |
| Output Voltage | 230 Volts |
| Output Current | 4.35 A |
| Output Waveform | Pure Sine Wave |
| Battery Type Required | External 12V DC (not included) |
| Form Factor | Stationary - Floor-standing |
| Color | Grey or Silver |
| Material | Metal |
| Connections | Schuko outlets, Battery connectors |
| Features | LCD display, Automatic Voltage Regulation (AVR), Surge Protection, Overheat Protection |
| Manufacturer | CSG S.A. |
| Country of Origin | China |
9. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the warranty card included with your product or visit the official Green Cell website. Keep your purchase receipt as proof of purchase.