1. Introduction
This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your Goodman GPGM3-3.0 Ton Packaged Gas/Electric Central Air System. This unit is an all-in-one comfort solution designed for residential applications, combining a gas-fired furnace, air conditioning condenser, evaporator coil, and a multi-speed ECM blower into a single unit.
The GPGM3 features a heavy-duty aluminized-steel heat exchanger for efficient heat transfer and an advanced coil design with aluminum fins and copper tubing for optimal efficiency. It utilizes a single-stage scroll compressor for reliable operation and an R-32 refrigerant for improved environmental performance. The unit is equipped for both downflow and horizontal airflow configurations.

Image 1.1: Goodman GPGM3 Packaged Gas/Electric Central Air System. This image shows the exterior of the packaged unit, typically a rectangular outdoor cabinet housing all components.
2. Safety Information
WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause property damage, personal injury, or loss of life. Refer to this manual. For assistance or additional information, consult a qualified installer or service agency.
- Always disconnect power to the unit before performing any service or maintenance.
- Ensure proper grounding to prevent electrical shock.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
- This appliance contains R-32 refrigerant. Only qualified personnel should handle refrigerant.
- Keep the area around the unit clear of obstructions to ensure proper airflow.
3. Setup and Installation
Installation of this packaged gas/electric central air system requires specialized knowledge and tools. It is strongly recommended that installation be performed by a qualified HVAC professional.
3.1 Pre-Installation Checks
- Verify that the unit model (GPGM33606031) matches the installation requirements.
- Ensure the installation site provides adequate clearance for airflow and service access.
- Confirm electrical supply (208-230V, 1 Ph) and gas supply meet local codes and unit specifications.
3.2 Unit Placement and Airflow
The GPGM3 unit is designed for flexible installation, supporting both downflow and horizontal airflow configurations. The installer must ensure the unit is properly leveled and secured on a suitable pad or support structure.
3.3 Connections
All electrical, gas, and ductwork connections must be made by a qualified technician in accordance with local and national codes. The unit features access panels to expedite installation and maintenance procedures.
4. Operating Instructions
Your Goodman GPGM3 system provides both heating and cooling functions, automatically adjusting to maintain your desired indoor temperature. The multi-speed ECM blower motor ensures efficient air circulation throughout your home.
4.1 Thermostat Operation
The system is controlled by a compatible thermostat. Refer to your thermostat's user manual for specific programming and operation instructions. Generally, you will select your desired mode (Heat, Cool, Auto) and set the temperature.
- Cooling Mode: The system will operate as an air conditioner, using the R-32 refrigerant to remove heat from your home.
- Heating Mode: The system will operate as a gas furnace, providing warmth to your home.
- Fan Mode: The multi-speed ECM blower can be set to run continuously or only when heating/cooling is active.
4.2 Initial Startup
After installation, a qualified technician will perform the initial startup and system checks to ensure proper operation and safety.
5. Maintenance
Regular maintenance is crucial for the longevity and efficient operation of your Goodman GPGM3 system. While some tasks can be performed by the homeowner, annual professional maintenance is highly recommended.
5.1 Air Filter Replacement
Check and replace the air filter monthly, or more frequently if the unit is in constant use or if you have pets. A dirty filter restricts airflow and reduces efficiency.
5.2 Outdoor Coil Cleaning
Keep the outdoor coil free of dirt, leaves, and other debris. Use a soft brush or vacuum to gently clean the coil fins. Ensure power is disconnected before cleaning.
5.3 Professional Annual Service
Schedule an annual inspection and tune-up by a qualified HVAC technician. This service typically includes:
- Checking refrigerant levels and pressures.
- Inspecting electrical connections and components.
- Cleaning and inspecting the heat exchanger.
- Lubricating moving parts (if applicable).
- Verifying proper thermostat operation.
6. Troubleshooting
Before calling for service, review the following common issues and solutions. For complex problems, always contact a qualified HVAC technician.
6.1 No Heating or Cooling
- Check the thermostat settings to ensure it is in the correct mode (Heat/Cool) and the temperature is set appropriately.
- Verify that the circuit breaker for the unit has not tripped.
- Ensure the outdoor unit has power.
6.2 Insufficient Heating or Cooling
- Check and replace dirty air filters.
- Ensure outdoor unit coils are clean and free of obstructions.
- Verify that all supply and return air vents are open and unobstructed.
6.3 Unusual Noises
Minor operational noises are normal. However, if you hear loud grinding, squealing, or banging noises, turn off the unit immediately and contact a service technician.
7. Specifications
The following table details the technical specifications for the Goodman GPGM3-3.0 Ton Packaged Gas/Electric Central Air System (Model: GPGM33606031).
| Specification | Value |
|---|---|
| Brand Name | Goodman |
| Model Info | GPGM33606031 |
| Item Weight | 370 pounds |
| Product Dimensions | 51 x 47 x 35 inches |
| Efficiency | Moderately Efficient |
| Capacity | 3 Tons |
| Annual Energy Consumption | 2540 Kilowatt Hours Per Year |
| Noise Level | 76 Decibels |
| Installation Type | Packaged |
| Form Factor | Packaged |
| Special Features | Ultra Low NOx (Nitrogen Oxide) Emissions |
| Color | Black |
| Voltage | 230 Volts |
| Wattage | 2000 watts |
| Included Components | Multi-speed ECM (Electronically Commutated Motor) blower motor |
| Cooling Power | 22800 British Thermal Units |
| Seasonal Energy Efficiency Ratio (SEER2) | 13.4 |
| AFUE | 0.81 % |
| Refrigerant Type | R-32 |
| Heating Capacity Nominal | 60000 Btu/H |
| Cooling Capacity Nominal | 33800 Btu/H |
8. R-32 Refrigerant Information
This Goodman GPGM3 unit utilizes R-32 refrigerant, a next-generation refrigerant with a lower Global Warming Potential (GWP) compared to older refrigerants. R-32 is an efficient and environmentally responsible choice for modern HVAC systems.
Video 8.1: R-32 Fact vs Fiction. This video provides information about R-32 refrigerant, addressing common misconceptions and highlighting its benefits and widespread use in HVAC systems globally. It clarifies that R-32 is used by over 50 manufacturers in over 130 countries.
9. Warranty and Support
Goodman offers a 10-year limited parts warranty with product registration. Please refer to the warranty documentation provided with your unit for full terms and conditions. Product registration is essential to activate your warranty.
For technical support, service, or warranty claims, please contact your installing dealer or a qualified Goodman service provider. You can also visit the official Goodman website for more information and to locate a service professional in your area.
Visit the Goodman Store for additional product information.