1. Introduction
Thank you for choosing the Electactic NCAA-08C/X1E Window Air Conditioner. This manual provides essential information for the safe and efficient operation, installation, and maintenance of your new air conditioner. Please read this manual thoroughly before use and retain it for future reference.
The NCAA-08C/X1E is a 12000 BTU window air conditioner designed to cool rooms up to 550 sq. ft. It features a 6-in-1 multifunctional design, offering Cool, Fan, Dry, Energy-Saving, Sleep, and Automatic modes. This unit is engineered for quiet operation, with a noise level as low as 52dB in silent mode, and includes a full-function remote control and a 24-hour timer for convenience.

Figure 1.1: Electactic NCAA-08C/X1E Window Air Conditioner, front view.
This image displays the Electactic NCAA-08C/X1E Window Air Conditioner, showcasing its compact and modern design. The front panel features air vents and a digital display, indicating its user-friendly interface.
2. Important Safety Information
To reduce the risk of fire, electric shock, or injury when using your air conditioner, follow these basic precautions:
- Read all instructions before using the appliance.
- Ensure the power supply matches the voltage specified on the unit's rating label.
- Do not operate the air conditioner with a damaged cord or plug.
- Do not insert fingers or foreign objects into the air inlet or outlet.
- Always unplug the unit before cleaning or servicing.
- Do not use the unit near flammable gases or combustible materials.
- Keep children away from the unit.
- Ensure the unit is installed securely in a window according to the installation instructions to prevent it from falling.
3. Product Components
The Electactic NCAA-08C/X1E Window Air Conditioner package includes the following items:
- 1 x Electactic NCAA-08C/X1E Window Air Conditioner (12,000 BTU)
- 1 x Remote Control
- 1 x User Manual (this document)
- Installation hardware (e.g., side panels, mounting brackets, screws - specific components may vary, refer to packaging)
4. Setup and Installation
Proper installation is crucial for the optimal performance and safety of your air conditioner. This unit is designed for installation in single- or double-hung windows.
4.1 Window Compatibility
Before installation, ensure your window meets the following requirements:
- Window Width Range: 24 to 48 inches wide.
- Maximum Sill Clearance: The maximum sill clearance required is 11 inches.

Figure 4.1: Window compatibility diagram for the air conditioner.
This image illustrates the window dimensions required for installation, showing the minimum and maximum window widths (24-48 inches) and the maximum sill clearance (11 inches). It also indicates compatibility with single- and double-hung windows.
4.2 Saddle-Shaped Design Benefits
The unique saddle-shaped design of this air conditioner allows for more natural light to enter the room and does not obstruct your view, providing an aesthetically pleasing and functional solution.

Figure 4.2: Benefits of the saddle-shaped air conditioner design.
This image highlights the advantages of the saddle-shaped design, emphasizing how it allows for more natural light and an unobstructed view. Key specifications like dimensions, dehumidifier capacity, BTU, cooling area, and compatible window size are also presented visually.
4.3 General Installation Steps (Summary)
- Prepare the Window: Open the window and ensure the sill and frame are clean and free of obstructions.
- Assemble Side Panels: Attach the accordion side panels to the air conditioner unit if they are not pre-assembled.
- Place the Unit: Carefully lift the air conditioner and place it into the window opening, ensuring it is centered and level. The saddle design will rest over the window sill.
- Secure the Unit: Extend the side panels to fill the window opening and secure them with screws to the window frame. Install any provided support brackets or angle irons to ensure the unit is firmly in place and cannot fall out.
- Seal Gaps: Use foam insulation strips or weatherstripping to seal any gaps around the unit and side panels to prevent air leakage.
- Plug In: Once securely installed, plug the unit into a grounded electrical outlet.
For detailed step-by-step installation instructions, refer to the dedicated installation guide included in your product packaging.
5. Operating Instructions
Your Electactic NCAA-08C/X1E air conditioner can be operated using the control panel on the unit or the included remote control.
5.1 Control Panel and Remote Control
Both the touch panel on the unit and the remote control offer full functionality to manage your air conditioner's settings, including mode selection, temperature adjustment, fan speed, and timer settings.
5.2 Operating Modes
The unit features 6 distinct operating modes:
- COOL Mode: Provides powerful cooling for summer. Adjust the temperature to your desired comfort level.
- FAN Mode: Circulates air without cooling. Useful for air circulation when cooling is not needed.
- DRY Mode: Designed for dehumidification in wet weather, removing excess moisture from the air.
- AUTO Mode: Automatically switches between cooling and fan mode based on the room temperature to maintain a set temperature.
- ENERGY-SAVING Mode: Starts by default to provide efficient and environmentally friendly cooling. The unit will cycle on and off to maintain the set temperature, saving energy.
- SLEEP Mode: Adjusts the temperature gradually overnight and operates at a lower fan speed for quiet operation, ensuring a comfortable sleeping environment.

Figure 5.1: Visual representation of operating modes.
This image illustrates the primary operating modes: COOL mode for powerful cooling, FAN mode for air circulation, DRY mode for dehumidification, and AUTO mode for automatic temperature regulation.
5.3 Timer Function
The 24-hour timer allows you to program the unit to turn on or off automatically at a specified time, providing greater flexibility and energy savings.
5.4 Quiet Operation
The Electactic NCAA-08C/X1E operates at a low noise level, as quiet as 52dB in silent mode, ensuring a peaceful resting or working environment.

Figure 5.2: Noise level comparison and energy-saving mode.
This image demonstrates the quiet operation of the air conditioner, comparing its noise level (around 45dB) to common sounds like gentle breeze and daily conversation. It also highlights the energy-saving mode, emphasizing quick, efficient, and silent cooling.
6. Maintenance
Regular maintenance ensures the longevity and efficient operation of your air conditioner. Always unplug the unit before performing any maintenance.
6.1 Air Filter Cleaning
The air filter should be cleaned every two weeks or more frequently depending on usage and air quality. A dirty filter can reduce cooling efficiency and airflow.
- Open the front panel of the unit.
- Carefully remove the air filter.
- Wash the filter with warm, soapy water. Rinse thoroughly.
- Allow the filter to air dry completely before reinserting it. Do not use hot water or dry with direct heat.
6.2 Exterior Cleaning
Wipe the exterior of the unit with a soft, damp cloth. Do not use harsh chemicals, abrasives, or solvents, as these can damage the surface.
6.3 Seasonal Storage
If storing the unit for an extended period (e.g., during winter):
- Unplug the unit and clean the air filter and exterior.
- Ensure the unit is completely dry to prevent mold or mildew growth.
- Store the unit in a dry, cool place, preferably in its original packaging.
7. Troubleshooting
Before contacting customer support, please refer to the following table for common issues and their solutions.
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not turn on. | No power, tripped circuit breaker, or unit unplugged. | Check power cord connection. Reset circuit breaker. Ensure outlet is functional. |
| Unit not cooling effectively. | Dirty air filter, blocked air vents, room too large, or windows/doors open. | Clean air filter. Clear any obstructions from air vents. Close windows and doors. Ensure unit BTU matches room size. |
| Water dripping from unit. | Unit not level, or drain pan/hose is blocked. | Ensure unit is slightly tilted outwards for proper drainage. Check and clear any blockages in the drain system. |
| Unusual noise. | Loose parts, unit not level, or foreign object inside. | Check for loose screws or components. Ensure unit is level. Unplug and inspect for foreign objects. If noise persists, contact support. |
8. Product Specifications
Detailed technical specifications for the Electactic NCAA-08C/X1E Window Air Conditioner:
| Feature | Detail |
|---|---|
| Model Number | NCAA-08C/X1E |
| Cooling Power | 12000 British Thermal Units (BTU) |
| Cooling Area | Up to 550 Sq.Ft. |
| Product Dimensions (D x W x H) | 28.94 x 18.7 x 14.96 inches |
| Item Weight | 68.2 pounds |
| Voltage | 115 Volts |
| Noise Level | 44 dB (min), 52dB (silent mode) |
| Dehumidifier Capacity | 72 Pints/day |
| Color | White |
| Special Features | Fast Cooling, Remote Controlled, 6-in-1 Multifunctional, Energy-Saving |
| Included Components | Air Conditioner, Remote Control, User Manual |

Figure 8.1: Electactic NCAA-08C/X1E showcasing airflow and energy efficiency.
This image visually represents the air conditioner's cooling capability, with green leaves symbolizing fresh, circulated air, hinting at its energy-efficient operation.
9. Warranty and Customer Support
9.1 Warranty Information
The Electactic NCAA-08C/X1E Window Air Conditioner comes with a 1 Year Warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use. Please retain your proof of purchase for warranty claims.
This warranty does not cover damage resulting from misuse, accident, alteration, neglect, unauthorized repair, or improper installation.
9.2 Customer Support
For any questions, technical assistance, or warranty claims, please contact Electactic Customer Support. You can typically find contact information on the manufacturer's website or through your retailer.