SASKATE SASKATEps3ngivh2e

SASKATE AN101 Volt Detector User Manual

Model: AN101 | Brand: SASKATE

1. Introduction

The SASKATE AN101 Volt Detector is a non-contact AC voltage tester designed for safe and efficient electrical testing. This device features a non-contact voltage (NCV) inductive probe, an integrated LED flashlight, and clear sound and light alarms to indicate the presence of AC voltage. It is an essential tool for electricians, DIY enthusiasts, and anyone needing to safely identify live and neutral wires or detect breakpoints in electrical circuits.

2. Safety Information

WARNING: ALWAYS TEST ON A KNOWN LIVE CIRCUIT BEFORE USE TO ENSURE THE DEVICE IS FUNCTIONING CORRECTLY.

  • Do not use the device if it appears damaged or is not operating properly.
  • Always follow local safety regulations and procedures when working with electricity.
  • This device is designed for non-contact detection. Do not attempt to make direct contact with live conductors.
  • Keep the device dry and clean. Do not expose to extreme temperatures or humidity.
  • Replace batteries promptly when the low battery indicator appears to ensure accurate readings.

Safety Class: CAT.III 1000V, CAT.IV 600V CE

3. Product Overview

The SASKATE AN101 is a compact and ergonomic voltage detector pen. It features an NCV sensor tip, an LCD display, power and sensitivity buttons, and an integrated LED flashlight.

SASKATE AN101 Volt Detector Pen, angled view

Image: Angled view of the SASKATE AN101 Volt Detector Pen, showing the red and black body, green LCD screen, and buttons.

SASKATE AN101 Volt Detector Pen with model name

Image: Side view of the SASKATE AN101 Volt Detector Pen, clearly displaying 'AN101 AC VOLTAGE DETECTOR' text on its body.

4. Specifications

ParameterValue
Item TypeVoltage Tester
ModelAN101
MaterialABS
Battery2 x 1.5V AAA Batteries (Not Included)
Operating VoltageAC 12-1000V, 50/60Hz
Alarm ModeSound and Light Alarm, Display Indication
LightingWhite LED Flashlight
LCD IndicatorRed for Live Line, Green for Neutral/Ground Line
Operating Temperature0~40℃ (32-104℉)
Storage Temperature-10~50℃ (14-122℉)
Humidity≤95%
Altitude≤2000m
Safety ClassCAT.III 1000V, CAT.IV 600V CE

5. Setup

Battery Installation

  1. Twist and remove the battery cap at the bottom of the detector.
  2. Insert two 1.5V AAA batteries, ensuring correct polarity (+/-).
  3. Replace the battery cap and twist to secure it.

The device will not function without batteries. Ensure batteries are inserted correctly for proper operation.

6. Operating Instructions

General Operation

  1. Press the power button (red button with power symbol) to turn on the device. The LCD screen will illuminate.
  2. To turn off, press and hold the power button until the display turns off. The device also features an auto-off function after a period of inactivity to conserve battery life.
Close-up of SASKATE AN101 Volt Detector screen and buttons

Image: Close-up view of the SASKATE AN101's LCD screen displaying 'AC' and battery level, along with the red power button and green sensitivity/flashlight button.

Neutral Wire Identification

Hold the sensor tip of the detector close to the wire or object to be tested. If the simulated grid point on the LCD lights up green and the buzzer beeps slowly, it indicates a neutral wire.

Live Wire Identification

Move the sensor tip of the detector closer to the wire or object to be tested. If the simulated grid point on the LCD lights up red and the buzzer sounds quickly, it indicates a live wire.

NCV Sensitivity Adjustment

The NCV sensitivity can be toggled by pressing the 'S' key (green button with 'S' and flashlight symbol). This allows for adjustment between high and low sensitivity modes, useful for different testing environments or for pinpointing voltage sources.

LED Flashlight

The device is equipped with a bright white LED flashlight. To activate or deactivate the flashlight, briefly press the 'S' key (green button with 'S' and flashlight symbol). This feature is particularly useful for working in dimly lit environments.

7. Maintenance

  • Cleaning: Wipe the device with a dry, clean cloth. Do not use abrasive cleaners or solvents.
  • Storage: Store the detector in a cool, dry place away from direct sunlight and extreme temperatures. If storing for an extended period, remove the batteries to prevent leakage.
  • Battery Replacement: Replace batteries as soon as the low battery indicator appears to ensure accurate readings and proper functionality.

8. Troubleshooting

  • Device does not turn on: Check if batteries are inserted correctly and have sufficient charge. Replace batteries if necessary.
  • Inconsistent readings: Ensure the sensor tip is clean. Move away from strong electromagnetic fields that might interfere with readings. Check battery level.
  • No detection: Ensure the device is turned on. Verify the circuit is indeed live by testing on a known live source. Adjust NCV sensitivity if needed.