MixBubole FLO1200-AGS Pro

MixBubole 1500W Macerator Pump FLO1200-AGS Pro Instruction Manual

Model: FLO1200-AGS Pro | Brand: MixBubole

1. Introduction

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your MixBubole 1500W Macerator Pump FLO1200-AGS Pro. Please read these instructions thoroughly before beginning any procedures to ensure proper function and longevity of the unit.

MixBubole 1500W Macerator Pump FLO1200-AGS Pro

Image 1.1: Front view of the MixBubole 1500W Macerator Pump FLO1200-AGS Pro.

2. Safety Information

Always observe basic safety precautions to reduce the risk of fire, electric shock, and personal injury. This unit operates with electricity and handles wastewater; improper installation or use can be hazardous.

  • Electrical Safety: Ensure the power supply matches the pump's requirements (110V-120V/60Hz). Do not operate with damaged cords or plugs.
  • Water Safety: Avoid contact with wastewater. Ensure all connections are watertight to prevent leaks.
  • Prohibited Items: Do not discharge any acids, alkalis, solvents, paint strippers, food waste, plastic, metal objects, sanitary napkins, condoms, cigarette butts, towels, wet wipes, or anything that could clog, damage the macerating unit, or void your warranty.
  • Ventilation: Ensure proper ventilation for the unit.

3. Product Overview

The MixBubole 1500W Macerator Pump FLO1200-AGS Pro is designed for efficient wastewater management in areas where gravity drainage is not feasible. It is suitable for connecting to toilets, sinks, showers, laundry, and kitchen fixtures.

3.1. Key Features

  • Powerful Motor: Equipped with a robust 1500-watt heavy-duty motor featuring an all-copper coil pack, designed for quiet operation and continuous use.
  • Sharpened Stainless Steel Grinding Blade: Capable of grinding various soft waste materials to ensure smooth water flow and prevent clogs.
  • Versatile Connections: Features four (4) universal wastewater inlets (Ø 40mm) and two (2) outlets, allowing connection to multiple fixtures.
  • PCB Delay Function: An upgraded model with a time delay function to prevent frequent cycling, ensuring quiet operation and energy efficiency.
  • Hot Water Resistance: Can handle continuous water temperatures up to 60°C and up to 4 hours at 90°C.
  • IPX4 Waterproof Design: Built to last in challenging conditions.
  • Compact Design: Measures L 20” x W 10” x H 17”, fitting seamlessly into shallow spaces.
MixBubole Macerator Pump features for toilet, washing machine, wash basin, shower cabin

Image 3.1: The macerator pump is suitable for various bathroom and utility fixtures.

Internal view of MixBubole Macerator Pump showing all-copper motor and grinding blade

Image 3.2: Illustration of the all-copper motor and sharpened stainless steel grinding blade.

Diagram explaining macerator and grinder functions

Image 3.3: Explanation of macerator and grinder functions for waste processing.

MixBubole Macerator Pump showing 4 inlets, 2 outlets, hot water resistance, and IPX4 rating

Image 3.4: Overview of the pump's multiple inlets, outlets, hot water capability, and IPX4 water resistance.

Close-up of the built-in check valve on the macerator pump

Image 3.5: The pump includes a built-in check valve for reliable operation.

4. Setup and Installation

The MixBubole Macerator Pump is designed for above-floor plumbing, eliminating the need for extensive modifications to existing sewage systems. All necessary fittings and clamps for installation are included.

4.1. Package Contents

Verify that all components are present before beginning installation:

  • Macerator Pump FLO1200-AGS Pro
  • Plastic Inlet Hoses
  • Hose Clamps (various sizes)
  • Toilet Connection Rubber Ring
  • Check Valve with Plastic Elbow
  • Activated Carbon Module
  • Plugs
  • Front Lid
Diagram of MixBubole Macerator Pump package contents

Image 4.1: All components included in the package for installation.

4.2. Installation Overview

The pump can be installed in various configurations to suit your needs, such as behind a toilet or integrated with other bathroom fixtures.

Examples of MixBubole Macerator Pump installations in shower room, toilet, washbasin, and laundry

Image 4.2: The compact design allows for versatile installation in various spaces.

Diagram showing installation of macerator pump with pipes behind a wall

Image 4.3: Installation option with the pump and pipes concealed behind a wall.

Diagram showing installation of macerator pump behind a toilet

Image 4.4: Installation option with the pump positioned behind the toilet.

Diagram showing various pipe sizes for easy installation of the macerator pump

Image 4.5: The pump supports various pipe sizes for flexible installation.

4.3. Detailed Installation Steps

For a visual guide on installation, please refer to the official product video below. Ensure all connections are secure and watertight.

Video 4.1: Official product video demonstrating the installation process for the MixBubole 1500W Macerator Pump FLO1200-AGS Pro.

5. Operating Instructions

5.1. Automatic Operation

The toilet pump features a fully automatic ON/OFF mechanism. It activates when the water level reaches 3 inches and automatically shuts off when the water level drops to 2 inches. The innovative switch system keeps electrical components safely above water, minimizing risk.

Close-up of the upgraded full-automatic switch on the macerator pump

Image 5.1: The pump features an upgraded full-automatic switch for reliable operation.

5.2. Manual Test Function

A manual button is included to allow for drainage tests, ensuring the system is functioning correctly after installation or maintenance.

6. Maintenance

Regular maintenance ensures the optimal performance and longevity of your MixBubole Macerator Pump.

6.1. Cleaning and Care

  • The outer shell is crafted from premium PP material, resistant to aging and scratches, making it easy to clean with mild soap and water.
  • Avoid using harsh chemicals or abrasive cleaners that could damage the unit.

6.2. Activated Carbon Module

The replaceable activated carbon module helps guarantee an odor-free environment. Check and replace the module periodically as needed to maintain effectiveness.

Image showing how to replace the activated charcoal module in the macerator pump

Image 6.1: The activated carbon module can be replaced to maintain an odor-free environment.

7. Troubleshooting

If you encounter issues with your macerator pump, refer to the following common problems and solutions:

  • Pump Not Activating: Check power connection. Ensure water level reaches the activation threshold (3 inches). Inspect for blockages in inlets or the grinding blade.
  • Unusual Noise: Verify that no foreign objects have entered the pump. Ensure all connections are secure.
  • Leaks: Check all hose clamps and seals for tightness. Ensure proper installation of the toilet connection rubber ring.
  • Reduced Flow: Inspect for partial blockages in the grinding chamber or discharge pipes.

If problems persist, contact customer service for assistance.

8. Specifications

FeatureSpecification
BrandMixBubole
Model NumberFLO1200-AGS Pro
Power SourceCorded Electric
Wattage1500 watts
Voltage110-120 Volts
Maximum Flow Rate46 Gallons Per Minute (2800 GPH)
Maximum Lifting Height32.8 Feet
Horizontal Discharge328 Feet
Item Weight19 Pounds
Product Dimensions16"L x 8"W x 11"H
MaterialPolypropylene (PP)
Water Inlets4 (Ø 40mm universal)
Outlets2
Noise Level45 dB
CertificationsGS and CE certified
Diagram showing the dimensions of the MixBubole Macerator Pump

Image 8.1: Key dimensions of the macerator pump.

Diagram illustrating the vertical and horizontal pumping capabilities of the macerator pump

Image 8.2: The pump's maximum vertical and horizontal lifting capabilities.

9. Warranty and Support

This utility sink pump comes with a 1-year manufacturer warranty. For any inquiries or assistance, MixBubole offers 7/24 customer service. Please retain your proof of purchase for warranty claims.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.