Faber 330.0738.738

Faber 60 cm 1200 m³/hr Autoclean Curved Chimney Instruction Manual

Model: 330.0738.738 | Brand: Faber

1. Introduction

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your new Faber 60 cm 1200 m³/hr Autoclean Curved Chimney. Please read all instructions carefully before using the appliance and retain this manual for future reference.

Faber 60 cm Autoclean Curved Chimney

Image 1.1: Faber 60 cm Autoclean Curved Chimney, front view.

2. Safety Information

Always follow basic safety precautions when using electrical appliances to reduce the risk of fire, electric shock, and injury. This appliance is for household use only.

  • Ensure the power supply matches the voltage specified on the appliance.
  • Do not operate the chimney with a damaged cord or plug.
  • Keep children away from the appliance during operation.
  • Do not flambé under the range hood.
  • Clean the oil collector regularly to prevent grease buildup and fire hazards.
  • Ensure adequate ventilation in the room when the chimney is used simultaneously with gas or other fuel-burning appliances.

3. Product Features

Your Faber Autoclean Curved Chimney is equipped with advanced features for an optimal kitchen environment:

  • Type: Black Curved Glass, Wall Mounted.
  • Filter Type: Filterless design for hassle-free maintenance.
  • Suction Power: 1200 m³/hr for effective smoke and odor removal.
  • Control Type: Touch Control, Gesture Control, and Motion Sensor for easy operation.
  • Speed Levels: 3 adjustable speed settings.
  • Noise Level: 59dB for quiet operation.
  • Special Features: Autoclean function, Built-in Oil Collector, and 1 LED Lamp.
Faber Chimney Silent Operation, Gesture Control, Black Glass

Image 3.1: Key features including silent operation, gesture control, and premium black glass finish.

Faber Chimney Low Noise Operation

Image 3.2: The chimney is designed for low noise operation, ensuring a quiet kitchen environment.

4. Setup and Installation

Proper installation is crucial for the performance and safety of your chimney. It is recommended to have the chimney installed by a qualified technician.

4.1 Pre-Installation Checks

  • Cabinet Size: Measure the clear width between your kitchen cabinets. Common chimney widths are 60 cm, 75 cm, and 90 cm. This model is 60 cm.
  • Height Clearance: Measure the height from your gas stove to the desired chimney base position. For T-shape/Curved models, a minimum clearance of 28-30 inches (71-76 cm) is typically recommended.
  • Power Supply: Ensure a suitable electrical outlet (230 Volts) is available near the installation area.
Faber Chimney Dimensions and Installation Clearance

Image 4.1: Chimney dimensions and recommended distance from the gas stove to the chimney base.

4.2 Installation Type

This chimney is suitable for ducted installation. For ductless use, a charcoal filter (to be purchased separately) is required. Contact customer support for more information on ductless conversion.

Faber Chimney Ducted vs Ductless Installation

Image 4.2: Illustration of ducted and ductless installation options.

4.3 Installation Guide Video

Watch this video for a visual guide on important measurements and installation considerations for your chimney.

Video 4.3: Chimney installation guide covering width and height measurements.

5. Operating Instructions

Your Faber chimney offers intuitive control options for a seamless cooking experience.

5.1 Control Panel

The chimney features a touch control panel, gesture control, and motion sensor for easy operation. The control panel typically includes buttons for power, speed adjustment (3 levels), light, and autoclean function.

Faber Chimney Touch Control

Image 5.1: Close-up of the touch control panel.

5.2 Gesture Control

To activate or adjust settings using gesture control, simply wave your hand in front of the motion sensor. Refer to the specific gesture patterns in the quick start guide for detailed instructions.

Faber Chimney Gesture Control

Image 5.2: Demonstrating gesture control for the chimney.

5.3 Speed Adjustment

Select from 3 speed levels to match your cooking needs. Use lower speeds for light cooking and higher speeds for heavy frying or grilling to ensure maximum smoke extraction.

6. Maintenance

Regular maintenance ensures the longevity and optimal performance of your Faber chimney.

6.1 Autoclean Function

The autoclean feature simplifies cleaning by collecting oil in a detachable tray. Activate the autoclean function as per the instructions in the quick start guide. This process helps maintain the chimney's efficiency without manual scrubbing.

Faber Chimney Autoclean and Oil Collector

Image 6.1: Autoclean feature with visible oil collector and LED light.

6.2 Oil Collector Cleaning

The built-in oil collector should be emptied and cleaned regularly. To remove, gently slide out the oil tray. Wash it with warm soapy water, rinse thoroughly, and ensure it is completely dry before reinserting.

6.3 Filterless Technology

This chimney features filterless technology, eliminating the need for traditional filter cleaning. The powerful suction and autoclean function manage grease and smoke effectively.

Faber Chimney Filterless Design

Image 6.2: Illustration of the filterless design.

Faber Chimney Powerful Filterless Suction

Image 6.3: Powerful suction without the need for messy filter cleaning.

7. Troubleshooting

If you encounter any issues with your chimney, refer to the following common troubleshooting steps:

ProblemPossible CauseSolution
Chimney not turning onNo power supply, loose connection, power outage.Check power plug, circuit breaker, and main power supply.
Low suction powerOil collector full, ducting obstruction, incorrect speed setting.Empty and clean oil collector. Check ducting for blockages. Increase speed setting.
Unusual noise during operationLoose parts, motor issue, foreign object in fan.Turn off and inspect for loose components. Contact service if noise persists.
Lights not workingLED lamp failure, loose wiring.Check connections. If LED is faulty, contact service for replacement.

If the issue persists after attempting these steps, please contact Faber customer support.

8. Specifications

AttributeValue
BrandFaber
Model Number330.0738.738
Product Dimensions (D x W x H)41D x 60W x 43H Centimeters
ColourBlack
Air Flow Capacity1200 Cubic Meters Per Hour
Noise Level59 Decibels
Mounting TypeWall Mount
Controls TypeTouch, Gesture
Voltage230 Volts
Number Of Speeds3
Light SourceLED
Filter TypeFilterless
Ventilation TypeDucted
Item Weight11400 Grams
Country Of OriginIndia

9. Warranty and Support

Your Faber chimney comes with comprehensive warranty coverage and dedicated support.

  • Product Warranty: 2 Years Comprehensive Warranty on the entire product.
  • Motor Warranty: 8 Years Warranty on the motor.

For warranty claims, service requests, or technical assistance, please contact Faber customer support at 1800-209-3484.

Faber Chimney Warranty Details

Image 9.1: Warranty information for the product and motor.

9.1 Extended Warranty Options

You may have options to extend your warranty coverage. Please refer to your purchase documentation or contact Faber for details on available extended warranty plans.

  • 3 Years Faber Protect+ Extended Warranty: Available from Faber.
  • 1 or 2 Years Total Protection: Available from Acko.

10. Product Overview Video

Watch this video for a comprehensive overview of the Faber Autoclean Curved Chimney's features and benefits.

Video 10.1: Detailed product overview of the Faber Autoclean Curved Chimney.

Ask a question about this manual