LGIB CPS-5HP

Download PDFFree PDF. The Save button below keeps a bookmark and private notes in your account.

LGIB CPS-5HP Single Phase to 3 Phase Converter Instruction Manual

Model: CPS-5HP

Introduction

This manual provides comprehensive instructions for the safe and efficient installation, operation, and maintenance of your LGIB CPS-5HP Single Phase to 3 Phase Converter. This device is designed to convert 220V single-phase power into 220-240V three-phase power, suitable for operating 5HP three-phase motors.

The converter features easy installation, safety and efficiency protections, wide compatibility with various motors, and a compact, lightweight design.

LGIB CPS-5HP Single Phase to 3 Phase Converter in a workshop setting, highlighting its features: Easy Installation, Safe & Energy-Efficient, Wide Compatibility, Compact & Lightweight.

Image: LGIB CPS-5HP Single Phase to 3 Phase Converter in a workshop setting, illustrating its key features.

Safety Guidelines

  • Always pair the phase converter with an air switch on the power input side (not the motor side) to ensure safety for both the motor and individuals.
  • Verify that the wire specifications and motor power are properly matched to ensure optimal performance and prevent insufficient voltage or unstable operation.
  • The phase converter can only be connected to one motor at a time. Do not connect it to other equipment.
  • If the motor power exceeds the rated power of the phase converter, it may be difficult or impossible to start, and the motor could overheat seriously.
  • If the wire gauge does not meet the required cross-sectional area, it will lead to startup failure. Increase the wire diameter when the cable length exceeds 50 meters.
  • After the phase converter starts successfully, the voltage at the connection terminals may vary with different power motors. This is due to the working characteristics of the phase converter.
  • The smaller the motor power is relative to the phase converter power, the higher the voltage between U-V and V-W.

Installation

The LGIB CPS-5HP converter is designed for easy and quick installation with direct wiring connections and no complex setup or programming required. For stable operation, use one motor per phase converter.

Wiring Connection Steps:

  1. Step 1: Input 220V Single-Phase. Connect the single-phase power supply to the input terminals (L/N) of the converter.
  2. Step 2: Wires Connect to Digital Phase Shifter. Ensure secure connections at the converter's input terminals.
  3. Step 3: Wires Connect to Motor. Connect the three-phase motor to the output terminals (U/V/W) of the converter.
  4. Step 4: Output 220V-240V 3-Phase. Verify all connections are secure before powering on.

Important: For safety, it is advisable to connect an air switch between the power supply and the phase shifter. Ensure the wire gauge meets standards to prevent insufficient voltage and unstable operation.

Diagram showing the wiring connection from a single-phase 220-240V input through an air switch to the Digital Phase Shifter, and then to a 3-phase motor.

Image: Easy and quick installation diagram for the phase converter, showing input from a single-phase source via an air switch to the converter, and then to a 3-phase motor.

Illustration of connecting two live wires to the input and three motor wires to the output of the phase converter.

Image: Visual guide for connecting input and output wires to the phase converter.

Installation Video:

Video: Detailed connection instructions for the LGIB CPS-5HP Single Phase to 3 Phase Converter. This video demonstrates the wiring process and safety considerations, including the use of an air switch and proper wire gauge selection.

Operation

Once properly installed, the LGIB CPS-5HP converter provides a stable and reliable three-phase power supply for your three-phase motor. The digital phase shifter maximizes efficiency.

Motor Power Matching Guide:

Refer to the table below for recommended motor power and load types for optimal performance with the CPS-5HP model.

Table showing motor power matching guide for CPS-5HP model, including motor HP, load type, and application recommendations.

Image: Motor Power Matching Guide for the CPS-5HP, detailing suitable motor horsepower for various load types and applications.

Voltage Detection:

The three-phase output of the CPS can be checked while the motor is running. If the motor is not running, the voltage of "V" and "W" will be zero.

Diagram illustrating voltage detection when the motor is running and not running, showing output voltages for U, V, W terminals.

Image: Voltage detection diagram, showing expected output voltages when the motor is running versus when it is idle.

Wide Compatibility:

This converter powers 5HP motors for various applications, including air compressors, pumps, grinders, saws, and fans. It is suitable for residential and light commercial use, such as garage workshops, woodworking workshops, small workspaces, and home garages.

Collage of images showing various applications for the phase converter, including garage workshops, woodworking workshops, small workspaces, and home garages.

Image: Examples of wide compatibility for the phase converter in different workshop and home garage environments.

Maintenance

No specific routine maintenance is required for the LGIB CPS-5HP converter beyond ensuring clean connections and proper ventilation. Regularly inspect wiring for any signs of wear or damage.

Troubleshooting

  • Motor Fails to Start or Overheats:
    • Check if the motor power exceeds the rated power of the phase converter.
    • Ensure the wire gauge meets the required cross-sectional area. Insufficient wire gauge can lead to startup failure, low voltage, and unstable motor speed. Increase wire diameter if cable length exceeds 50 meters.
  • Unstable Motor Speed: This can be caused by an insufficient wire gauge. Verify wire specifications.
  • No Voltage on V and W Terminals: This is normal if the motor is not connected or not running. The three-phase output can only be checked when the motor is actively running.
  • Lockout after 5 Consecutive Restart Failures: The unit has user-friendly protections including motor overload and automatic restart. Normal operation can be restored by power cycling the unit.
Table showing motor power and cable matching guide, indicating recommended wire gauges for different motor HP and load types.

Image: Motor Power & Cable Matching Guide, providing recommendations for wire specifications based on motor horsepower and load type.

Specifications

FeatureDetail
Model NameCPS-5HP
BrandLGIB
Horsepower Range4-5HP (4 KW)
Input VoltageSingle-phase 220-240V
Output VoltageThree-phase 220-240V
Frequency50/60Hz
Maximum Current15A
Product Weight5.29 lbs / 2.4 kg
Product Dimensions9.8 x 5.9 x 5.3 inches / 250x150x135 mm
Main MaterialPlastic
ProtectionsMotor Overload, Automatic Restart, Lockout after 5 consecutive restart failures
Recommended UsesHome, Workshop
Energy Specifications MetUL
Image showing the dimensions and key specifications of the LGIB CPS-5HP Digital Phase Shifter.

Image: Detailed specifications and dimensions of the LGIB CPS-5HP converter.

Warranty

The LGIB CPS-5HP Single Phase to 3 Phase Converter comes with a 1-year warranty. Please retain your proof of purchase for warranty claims.

Support

For any questions or professional assistance regarding your LGIB CPS-5HP converter, please contact the seller, ArtPro Tools, through the Amazon platform or refer to the contact information provided with your purchase.

© 2026 LGIB. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.