SGPWATT 11.4KW-48V

SUNGOLDPOWER 11.4KW 48V Solar Hybrid Inverter User Manual

Model: 11.4KW-48V

1. Introduction

This manual provides essential information for the installation, operation, and maintenance of the SUNGOLDPOWER 11.4KW 48V Solar Hybrid Inverter. Please read this manual thoroughly before installation and use to ensure proper function and safety.

The SUNGOLDPOWER 11.4KW 48V Solar Hybrid Inverter is designed to integrate solar power, battery storage, and grid power to provide a reliable and efficient energy solution for both on-grid and off-grid applications. It features 3 MPPTs for high solar input, scalable power up to 102.6KW with parallel operation, and advanced monitoring capabilities.

2. Safety Information

Important Safety Instructions:

  • Installation must be performed by qualified personnel in accordance with local electrical codes and regulations.
  • Do not attempt to disassemble or repair the inverter. Refer all servicing to qualified service personnel.
  • Ensure proper grounding of the inverter.
  • Disconnect all power sources (solar, battery, grid) before performing any maintenance or wiring.
  • The inverter contains high voltage components. Exercise extreme caution.
  • Install the inverter in a well-ventilated area, away from flammable materials and direct sunlight.
  • This inverter is rated IP65, suitable for outdoor installation, but protection from direct heavy rain or snow is recommended.

3. Product Overview

3.1 Key Features

  • High Solar Input: 3 MPPTs, up to 600V PV input per MPPT, supporting a total solar input of 15KW with a maximum 210A charging current.
  • Scalable Power: Connect up to 9 inverters in parallel for a maximum 102.6KW system.
  • Advanced AC Coupling: Integration with grid-tie systems and smart load management.
  • Monitoring: Via LCD display and mobile application (Bluetooth/WiFi).
  • Certifications: UL 1741/CSA C22.2/UL 1699B UL 1741SB, IEEE 1547:2018, HECO SRD 2.0.
  • Durability: IP65 rated, wall-mounted design.
SUNGOLDPOWER 11.4KW 48V Solar Hybrid Inverter with key specifications
Figure 3.1.1: SUNGOLDPOWER 11.4KW 48V Solar Hybrid Inverter highlighting key specifications.

This image displays the SUNGOLDPOWER 11.4KW 48V Split Phase Hybrid Inverter, emphasizing its core capabilities: Max. PV Input Power of 15KW, MAX Open Circuit Voltage of 600V, and Max Charge Current of 210A. The nominal output voltage is 120/240V (split phase) or 208V (2/3 phase) AC.

3.2 Inverter Appearance and Components

SUNGOLDPOWER 11.4KW 48V Solar Hybrid Inverter front view
Figure 3.2.1: Front view of the SUNGOLDPOWER 11.4KW 48V Solar Hybrid Inverter.

This image displays the front of the SUNGOLDPOWER 11.4KW 48V Solar Hybrid Inverter. It features a sleek, grey and black design with the SUNGOLDPOWER logo. The upper section includes an LED indicator panel and an LCD screen for displaying operational status and data. The lower section is a solid panel, indicating internal components.

Inverter Appearance with labeled components and internal structure
Figure 3.2.2: Detailed view of inverter components and connections.

This diagram illustrates the external and internal components of the inverter. Key external features include handle areas, PV switch, toggle latch for the wire box cover, ON/OFF button, and the LCD display. The top panel shows connection ports for Battery, PV, COM (GPRS/WiFi/LAN), and GEN. An internal structure view highlights the circuit board and wiring terminals.

4. Setup and Installation

4.1 Unpacking and Inspection

Upon receiving the inverter, carefully unpack it and inspect for any shipping damage. Report any damage to your supplier immediately.

Packaging and dimensions of the SUNGOLDPOWER inverter and included accessories
Figure 4.1.1: Inverter packaging, dimensions, and included accessories.

This image shows the inverter's approximate dimensions (31.5 inches length, 16.5 inches width, 9.4 inches height) and its net weight of 88 lbs. It also illustrates the contents of the package: the inverter unit, user manual, mounting bracket, WiFi module, CT cable, parallel communication cable, 1X9-Pin terminal & 3X4-Pin terminal, BTS cable, and M6 expansion/security screws.

4.2 Installation Location

  • Choose a location that is dry, well-ventilated, and protected from direct sunlight and extreme temperatures.
  • Ensure sufficient clearance around the inverter for proper airflow and heat dissipation.
  • The inverter is designed for wall-mounting. Use the provided mounting bracket and hardware.

4.3 Wiring Diagram

Refer to the following diagram for a typical inverter application system setup.

Inverter application system diagram
Figure 4.3.1: Diagram of a typical inverter application system.

This diagram illustrates how the 11.4KW Hybrid Inverter integrates into an energy system. It shows connections from a PV Array to the inverter, and from the inverter to a Battery bank, Grid (via a Sensor), and various loads (Normal Load, Smart Load). The system also supports a Generator or On-Grid Inverter, and includes a Monitoring Device connected to the Cloud for remote access.

Wiring Steps:

  1. Connect the battery cables to the inverter's battery terminals, ensuring correct polarity.
  2. Connect the PV array cables to the inverter's PV input terminals, observing polarity and voltage limits.
  3. Connect the AC input from the grid to the inverter's grid input terminals.
  4. Connect the AC output to your loads.
  5. Ensure all connections are secure and properly insulated.
  6. Connect communication cables (WiFi module, BMS, parallel cable) as required.

5. Operating Modes

The inverter supports various operating modes to optimize energy usage based on your preferences and grid conditions.

Diagram of four AC output work modes: Self-consumption, Feed-in Priority, Back-up, and Off Grid Mode
Figure 5.1.1: Overview of the four AC output work modes.

This diagram illustrates the four primary AC output work modes: Self-consumption, Feed-in Priority, Back-up, and Off Grid Mode. Each mode shows the flow of energy between the load, battery, and grid, indicating how the inverter prioritizes power sources under different conditions.

  • Self-consumption Mode: Prioritizes using solar power and battery energy for local loads before drawing from the grid.
  • Feed-in Priority Mode: Prioritizes feeding excess solar power back into the grid.
  • Back-up Mode: Ensures continuous power to critical loads using battery backup when the grid fails.
  • Off Grid Mode: Operates independently from the utility grid, relying on solar and battery power.

5.1 Forced Charge/Discharge Function

The inverter allows users to set specific time periods for forced battery charging or discharging, regardless of the current operating mode (Self-consumption, Feed-in Priority, or Back-up Mode).

Forced Charge/Discharge Function diagram
Figure 5.1.2: Forced Charge/Discharge Function timeline.

This diagram illustrates the forced charge/discharge function over a 24-hour period. It shows three configurable time periods (T1, T2, T3) for forced charge/discharge parameter settings, interspersed with periods (M) where the inverter operates in Self-consumption, Feed-in Priority, or Back-up Mode.

6. Monitoring and Control

6.1 LCD Display

The inverter features an integrated LED and LCD HD display for real-time monitoring of PV input, battery status, grid status, backup power, communication status, and alarms.

LED and LCD HD Display of the SUNGOLDPOWER inverter
Figure 6.1.1: LED and LCD HD Display interface.

This image highlights the LED and LCD HD display of the inverter. The LED indicators show status for PV, BAT (battery), GRID, BACKUP, COM (communication), and ALARM. The LCD screen provides detailed numerical data and operational mode information, allowing users to monitor and adjust settings directly.

6.2 Mobile Application (APP)

The inverter can be monitored and customized via a mobile application through Bluetooth or WiFi connectivity. This allows for real-time data checks and remote setting adjustments.

Mobile application for monitoring and customizing the inverter
Figure 6.2.1: Mobile application interface for inverter management.

This image shows a smartphone displaying the inverter's mobile application interface. The app provides real-time data, allowing users to check energy flow, battery status, and customize inverter settings remotely. The inverter unit is shown mounted on a wall, with battery units below, indicating a complete system setup.

7. Parallel Operation

For increased power output, up to 9 SUNGOLDPOWER 11.4KW 48V Solar Hybrid Inverters can be connected in parallel, creating a system with a maximum capacity of 102.6KW.

Diagram showing multiple inverters connected in parallel for scalable power
Figure 7.1.1: Parallel connection of multiple inverters.

This diagram illustrates how multiple SUNGOLDPOWER inverters can be connected in parallel to achieve scalable power. Three inverters are shown connected to a common busbar, which then connects to a bank of batteries, demonstrating a larger system configuration.

Refer to the dedicated parallel operation manual for detailed wiring and configuration instructions.

8. Battery Compatibility

The inverter offers wide compatibility with various battery types, including Flooded (FLD), AGM, LiFePO4 (LI), GEL, Sealed Lead Acid (SLD), and user-defined battery settings.

Inverter compatibility with various battery types
Figure 8.1.1: Supported battery types.

This image displays the SUNGOLDPOWER inverter surrounded by icons representing different battery types it is compatible with: Flooded (FLD), AGM, LiFePO4 (LI), GEL, Sealed Lead Acid (SLD), and User-defined. This highlights the inverter's versatility in battery integration.

9. Specifications

Detailed technical specifications for the SUNGOLDPOWER 11.4KW 48V Solar Hybrid Inverter (Model SGN11.4KHB-48).

Inverter Model SGN11.4KHB-48 specifications table
Figure 9.1.1: Technical specifications table from manufacturer.

This image presents a detailed table of technical specifications for the SUNGOLDPOWER SGN11.4KHB-48 inverter. It covers Rated Output Power, DC Volt, Rated Output Voltage, Parallel capability, AC Output as backup, AC Output Data (On-Grid), Solar Charger & AC Charger details (MPPT type, Max PV Array Power, MPPT Operation Voltage, Max PV Array Open Circuit Voltage, Max DC Input current per string, Number of MPPT Tracker, Max Charge/Discharge Current), and General specifications (Ingress Protection Degree, Dimensions, Net Weight, Communication Interface).

CategorySpecification
Model Name11.4KW-48V (SGN11.4KHB-48)
Rated Output Power15,000W
DC Volt48V DC
Rated Output Voltage120V/240V (split phase) / 208V (2/3 phase) VAC
Parallel CapabilityYes, up to 9 units
Max. AC Output Power (PF=1)11,400W
Peak Power20,000VA
Nominal Output Frequency50Hz/60Hz
Nominal Grid Output Power11,400W
Nominal Grid AC Output Current47.5A
Solar Charger TypeMPPT
Maximum PV Array Power15,000W
MPPT Operation Voltage70-540VDC
Maximum PV Array Open Circuit Voltage600VDC
Max. DC Input current / per string32A/22A/22A
Number of MPPT Tracker3
Max. Charge/Discharge Current210A/210A
Ingress Protection DegreeIP65/NEMA 3R
Dimensions (W*H*D)16.5"x31.5"x9.4" (420*800*240mm)
Net Weight88lb/40Kg
Communication InterfaceRS485/CAN (for BMS), DRM/RS485 (for meter), RS485, Optional: Wi-Fi/LAN

10. Troubleshooting

This section provides guidance for common issues. For complex problems, contact technical support.

10.1 Common Issues and Solutions

  • Inverter not powering on: Check all DC and AC connections. Ensure the ON/OFF switch is in the 'ON' position. Verify battery voltage is within the operating range.
  • No solar power input: Check PV array connections and ensure no shading. Verify PV voltage is within MPPT operating range.
  • Error codes on LCD: Refer to the full user manual (PDF) for a comprehensive list of error codes and their corresponding troubleshooting steps.
  • Communication issues (WiFi/Bluetooth): Ensure the WiFi module is correctly installed and configured. Check network connectivity. Restart the inverter and communication module.

11. Maintenance

Regular maintenance ensures optimal performance and longevity of your inverter.

  • Cleaning: Periodically clean the inverter's exterior with a dry, soft cloth. Ensure ventilation openings are free from dust and debris. Do not use liquid cleaners.
  • Connections: Annually inspect all electrical connections for tightness and signs of corrosion.
  • Environment: Ensure the installation environment remains within specified temperature and humidity ranges.
  • Firmware Updates: Check for available firmware updates from the manufacturer to ensure optimal performance and access to new features.

12. What's in the Box

The product package includes the following items:

  • 11.4KW Inverter Unit
  • WiFi Module
  • BTS Cable
  • Parallel Cable
  • CT Cable
  • User Manual (PDF available online)
  • Mounting Bracket
  • 1X9-Pin Terminal & 3X4-Pin Terminal
  • M6 Expansion Screws & M6 Security Screws

13. Warranty and Support

The SUNGOLDPOWER 11.4KW 48V Solar Hybrid Inverter comes with a 10-year warranty.

For technical support, warranty claims, or further assistance, please contact your authorized SGPWATT dealer or visit the official SGPWATT website. Ensure you have your model number (11.4KW-48V) and purchase details available when contacting support.

A comprehensive user manual in PDF format is available for download: SUNGOLDPOWER 11.4KW 48V Solar Hybrid Inverter User Manual (PDF)

Related Documents - 11.4KW-48V

Preview ECO-WORTHY 3.5KW Solar Off-Grid Inverter User Manual
This user manual provides comprehensive safety, installation, and operating instructions for the ECO-WORTHY 3.5KW Solar Off-Grid Inverter (Model ECO3500W(SR)). Learn about system setup, wiring, operating modes, and technical specifications for efficient solar energy management.
Preview PowMr Solar Inverter User Manual
Comprehensive user manual for the PowMr Solar Inverter, detailing installation, operation, safety instructions, technical specifications, and troubleshooting for this 5000W off-grid 48V inverter.
Preview ECGSOLAX 6.5KW Hybrid Solar Inverter User Manual: Installation & Operation Guide
Comprehensive user manual for the ECGSOLAX 6.5KW Hybrid Solar Inverter. Covers installation, operation, safety instructions, troubleshooting, and specifications for models like ECG-HVM, ECG-HVM5K-24V, and ECG-hvm6.5k-48v.
Preview Sunnysoft Pure Sine Wave Inverter | Intelligent LCD Display
Comprehensive guide to the Sunnysoft Pure Sine Wave Inverter, featuring an intelligent LCD display. Learn about its specifications, installation, usage, safety precautions, and error codes for reliable power solutions.
Preview Sumry HGX 4KW Hybrid Solar Inverter - Technical Specifications & User Guide
Comprehensive technical specifications, features, and troubleshooting guide for the Sumry HGX 4KW hybrid solar inverter. Learn about AC voltage, DC input, battery compatibility, error codes, and settings.
Preview Giandel PS-4000QAR 4000W Pure Sine Wave Power Inverter User Manual
Comprehensive user manual for the Giandel PS-4000QAR 4000W Pure Sine Wave Power Inverter. Covers specifications, installation, operation, safety warnings, troubleshooting, and warranty information for reliable DC to AC power conversion.