1. Introduction
The DIGITEN THT1032 is a versatile temperature and humidity controller designed for precise environmental management. It features three independent outlets for controlling heating/cooling, humidification/dehumidification, and timed operations. Equipped with dual high-precision probes, this device is suitable for various applications including reptile enclosures, mushroom cultivation, plant seeding, and home brewing.
2. Key Features
- Plug & Play Operation: Simple setup with intuitive buttons for quick configuration.
- Dual High-Precision Probes: Separate probes for temperature (accuracy: ±0.4°C/±0.7°F) and humidity (accuracy: ±3%).
- Triple-Zone Precision Control: Three independent outlets for temperature, humidity, and timed devices.
- Large LCD Display: Clear, real-time monitoring with switchable Fahrenheit/Celsius units.
- Climate Customization: Combine heating/cooling with humidification/dehumidification, and program the third outlet for timers.
3. Package Contents
- DIGITEN THT1032 Controller Unit
- Temperature Probe
- Humidity Probe
- User Manual
4. Product Overview
The DIGITEN THT1032 controller features a main unit with a large LCD display, control buttons, three power outlets, and two external probes for temperature and humidity sensing.

Image 1: Front view of the DIGITEN THT1032 controller, showing the display, buttons, and three power outlets.
4.1. Control Panel and Display
The front panel includes an LCD screen and four control buttons: SET, MODE, Up (▲), and Down (▼).

Image 2: Detailed view of the controller's outlets and control buttons. OUT1 is for temperature, OUT2 for humidity, and OUT3 for timer functions.
- SET Button: Used to select an outlet for configuration or confirm settings.
- MODE Button: Used to change the operating mode (e.g., heating/cooling, humidification/dehumidification, timer program).
- Up (▲) Button: Increases values or navigates menu options.
- Down (▼) Button: Decreases values or navigates menu options.
- OUT1: Temperature controlled outlet.
- OUT2: Humidity controlled outlet.
- OUT3: Timer controlled outlet.
4.2. Probes
The controller comes with two separate probes: one for temperature and one for humidity. These probes are essential for accurate environmental monitoring.

Image 3: The temperature probe (left) and humidity probe (right) connected to the controller, illustrating their distinct functions.
5. Initial Setup
- Connect Probes: Plug the temperature probe and humidity probe into their respective ports on the controller. Ensure they are securely connected.
- Placement: Position the probes in the environment you wish to monitor and control. Ensure they are not directly exposed to heat sources, moisture, or airflow that could skew readings.
- Power On: Plug the controller into a standard 120V AC power outlet. The display will illuminate, showing current temperature, humidity, and time.
- Connect Devices: Plug your heating/cooling device into OUT1, your humidification/dehumidification device into OUT2, and any timed appliance (e.g., lights, misters) into OUT3.
6. Operating Instructions
6.1. Setting Temperature Control (OUT1)
- Press the SET button repeatedly until OUT1 is selected (indicated by a flashing OUT1 icon or similar).
- Use the Up (▲) or Down (▼) buttons to adjust the desired target temperature.
- Press MODE to cycle through heating (HEAT) or cooling (COOL) modes. Select the appropriate mode for your connected device.
- Press SET to confirm the temperature and mode.
- To set the temperature differential (hysteresis), press and hold SET for a few seconds when OUT1 is selected. Use Up/Down to adjust the difference between the set point and when the device turns on/off. Press SET to confirm.
6.2. Setting Humidity Control (OUT2)
- Press the SET button repeatedly until OUT2 is selected.
- Use the Up (▲) or Down (▼) buttons to adjust the desired target humidity percentage.
- Press MODE to cycle through humidification (HUMIDIFICATION) or dehumidification (DEHUMIDIFICATION) modes. Select the appropriate mode.
- Press SET to confirm the humidity and mode.
- To set the humidity differential, press and hold SET for a few seconds when OUT2 is selected. Use Up/Down to adjust. Press SET to confirm.
6.3. Setting Timer Control (OUT3)
- Press the SET button repeatedly until OUT3 is selected.
- Press MODE to enter the timer programming interface.
- Use Up (▲) or Down (▼) to set the ON time (hour and minute). Press SET to move to the next setting.
- Set the OFF time (hour and minute) using Up/Down and SET.
- The controller supports multiple ON/OFF programs for OUT3. Refer to the on-screen prompts for additional program slots.
- Press SET to save and exit the timer settings.
6.4. Switching Temperature Units (°C/°F)
To switch between Celsius and Fahrenheit, press and hold the Up (▲) button for approximately 3 seconds. The display will change accordingly.
7. Maintenance
- Cleaning: Wipe the controller unit with a soft, dry cloth. Do not use abrasive cleaners or immerse the unit in water.
- Probe Care: Keep the probes clean and free from debris. Avoid bending or damaging the probe cables. If probes become dirty, gently clean them with a damp cloth and allow them to dry completely before re-use.
- Storage: When not in use, store the controller in a cool, dry place away from direct sunlight and extreme temperatures.
8. Troubleshooting
| Issue | Possible Cause | Solution |
|---|---|---|
| Display is blank or not powering on. | No power supply; loose connection. | Ensure the controller is securely plugged into a live power outlet. Check the power source. |
| OUT1/OUT2/OUT3 not activating connected device. | Incorrect settings; device malfunction; power issue. | Verify temperature/humidity/timer settings. Check if the connected device is working independently. Ensure the controller's set point is met for activation. |
| Humidity probe shows "ERR" reading. | Probe malfunction; damaged cable; sensor error. | Check the humidity probe connection. Inspect the probe cable for damage. If the error persists, the probe may need replacement. |
| Inaccurate temperature/humidity readings. | Probe placement; dirty probe; probe malfunction. | Relocate probes away from direct heat/moisture/airflow. Clean probes gently. If issues persist, consider probe replacement. |
9. Technical Specifications
| Specification | Value |
|---|---|
| Model Number | THT1032 |
| Power Requirement | 100-240VAC |
| Load Capacity | 10A per outlet (1100W@110V, 2200W@220V) |
| Temperature Control Range | -10°C to 120°C / 14°F to 248°F |
| Temperature Accuracy | ±0.4°C / ±0.7°F |
| Humidity Accuracy | ±3% |
| Probe Sensor Type | Digital Signal Output, I2C Interface |
| Operating Environment Temperature | 0-50°C / 32-122°F |
| Operating Environment Relative Humidity | <85% |
| Display Type | LCD |
| Material | Plastic |
| Color | Gray |
| Item Weight | 1.04 pounds |
| Package Dimensions | 6.85 x 6.34 x 1.93 inches |
10. Warranty and Customer Support
DIGITEN provides a one-year warranty for any quality-related issues with this product. For technical assistance, troubleshooting, or warranty claims, please contact DIGITEN customer support through the retailer where the product was purchased or visit the official DIGITEN website for contact information.
Please retain your proof of purchase for warranty service.