Mayoki SMP-DCB20

Mayoki Cordless Submersible Sump Pump User Manual

Model: SMP-DCB20

1. Introduction

Thank you for purchasing the Mayoki Cordless Submersible Sump Pump, Model SMP-DCB20. This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your pump. Please read this manual thoroughly before use and retain it for future reference.

2. Safety Information

Always observe basic safety precautions to reduce the risk of fire, electric shock, and personal injury. This pump is designed for water transfer only. Do not use with flammable liquids or in explosive atmospheres.

3. Package Contents

Verify that all items are present upon unpacking:

Note: Dewalt 20V battery and charger are not included.

4. Product Overview

The Mayoki SMP-DCB20 is a portable, cordless submersible pump designed for efficient water transfer in various applications such as draining pools, basements, garden ponds, and flooded areas. It features a brushless motor, three flow settings, and automatic water detection.

Mayoki Cordless Submersible Sump Pump with Battery Enclosure

Figure 4.1: Main components of the Mayoki Cordless Submersible Sump Pump, including the pump unit and the separate battery enclosure connected by a power cord.

Diagram of Mayoki Sump Pump features including strainer, outlet, battery enclosure, and controls

Figure 4.2: Detailed diagram highlighting key features: integrated strainer, 3/4" NH outlet, water-resistant battery enclosure, power switch, and 3-mode flow setting switch with indicator.

5. Setup

  1. Install Battery: Open the water-resistant battery enclosure. Insert a charged Dewalt 20V battery into the designated slot. Close the enclosure securely to maintain its IPX4 rating.
  2. Connect Discharge Hose: Attach a standard 3/4" garden hose to the pump's 3/4" NH outlet. Ensure the connection is tight to prevent leaks. Do not overtighten the elbow fitting if used, as it may break.
  3. Position Pump: Place the pump in the area to be drained, ensuring it is fully submerged in water. The integrated strainer at the base will filter debris.
  4. Route Power Cord: Position the battery enclosure in a dry, accessible location, away from the water source, using the 15.4ft extension cord.
Mayoki Sump Pump operating in water with a hose connected

Figure 5.1: The sump pump positioned in water with a discharge hose attached, ready for operation.

6. Operation

  1. Power On: Press the power button on the battery enclosure to turn on the pump. The indicator lights will illuminate.
  2. Select Flow Mode: Use the mode selection button to choose one of the three flow settings:
    • L (Low): Approximately 792 GPH
    • M (Medium): Approximately 1056 GPH
    • H (High): Approximately 1320 GPH
  3. Automatic Water Detection & Shutdown: The pump features a built-in water source detection. If no water is detected for approximately 10 seconds, the pump will automatically stop to prevent dry running and extend its lifespan.
  4. Restarting the Pump: If the pump shuts down due to lack of water, it will not automatically restart when water levels rise again. You must manually press the power button to restart the pump.
  5. Power Off: Press the power button again to turn off the pump when draining is complete or if you need to pause operation.
Close-up of the battery enclosure control panel showing three flow settings: Low, Medium, High

Figure 6.1: The control panel on the battery enclosure, illustrating the power button and the 3-mode flow setting switch.

Mayoki Sump Pump discharging water, indicating automatic water detection and shutdown feature

Figure 6.2: The pump in operation, demonstrating its ability to discharge water and its auto-stop function when water is no longer detected.

7. Maintenance

Regular maintenance ensures optimal performance and extends the life of your pump.

8. Troubleshooting

If you encounter issues, refer to the following troubleshooting guide:

ProblemPossible CauseSolution
Pump does not startBattery not charged or improperly installed; Power button not pressed; Pump is dry.Ensure battery is charged and correctly inserted. Press the power button. Ensure pump is submerged in water.
Low flow rateClogged strainer; Kinked or obstructed hose; Low battery charge; Incorrect flow setting.Clean the integrated strainer. Check hose for obstructions. Recharge battery. Select a higher flow mode (M or H).
Pump stops unexpectedlyAutomatic water detection shutdown (no water); Overload protection activated; Low battery.Verify water level. If water is present, check for obstructions. Recharge battery. Manually restart the pump if it stopped due to low water.
Water leakage from connectionsLoose hose connection; Damaged hose or adapter.Tighten hose connections. Inspect hose and adapter for damage and replace if necessary.

9. Specifications

Technical specifications for the Mayoki Cordless Submersible Sump Pump SMP-DCB20:

FeatureSpecification
BrandMayoki
Model NumberSMP-DCB20
Power SourceBattery Powered (Compatible with Dewalt 20V)
Voltage20 Volts (DC)
Wattage130 watts
Maximum Flow Rate1320 GPH (22 Gallons Per Minute)
Maximum Lifting Height26 Feet
Product Dimensions9"L x 9"W x 7.9"H
Item Weight3.74 pounds (1.7 Kilograms)
MaterialPlastic
Outlet Size3/4" NH
Cord Length (Pump to Battery Enclosure)15.4 Feet
Diagram showing dimensions and key specifications of the Mayoki Sump Pump and battery enclosure

Figure 9.1: Visual representation of the pump and battery enclosure dimensions and key specifications.

10. Warranty and Support

The Mayoki Cordless Submersible Sump Pump SMP-DCB20 comes with a 5-year warranty, covering defects in materials and workmanship under normal use. Please retain your proof of purchase for warranty claims.

For technical support, warranty service, or questions regarding your product, please contact Mayoki customer service through the retailer's platform or the official Mayoki website. Provide your model number (SMP-DCB20) and purchase date when contacting support.

Related Documents - SMP-DCB20

Preview Mellif SMP-DCB20 Submersible Water Pump Operation Manual
Official operation manual for the Mellif SMP-DCB20 cordless submersible water pump. Find detailed specifications, safety instructions, setup guides, operational procedures, maintenance advice, and troubleshooting solutions for effective use in home and garden applications.
Preview Mellif PS-DCB20 Electric Pruning Shears Instruction Manual
Instruction manual for the Mellif PS-DCB20 Electric Pruning Shears. Provides safety instructions, operating procedures, maintenance guidelines, and specifications for this cordless garden tool.
Preview Extron Media Processors and Encoders: Streaming to Third Parties using RTMP and RTMPS
A technical application note providing guidance on setting up Extron Streaming Media Processors and Encoders for publishing live streams to third-party services like Wowza Video using RTMP and RTMPS protocols.
Preview Fiche Technique Plateforme d'Automatisation Eaton SMP DA-3050
Découvrez la plateforme d'automatisation compacte et évolutive Eaton SMP DA-3050. Ce document technique détaille ses caractéristiques, ses avantages en matière de cybersécurité, sa fiabilité, son intégration facile et sa productivité pour les réseaux électriques, industriels et commerciaux.
Preview Extron SMP 300 Series User Guide
Comprehensive user guide for the Extron SMP 300 Series Streaming Media Processors, covering installation, configuration, operation, and troubleshooting for models SMP 351, SMP 351 3G-SDI, SMP 352, and SMP 352 3G-SDI.
Preview Extron SMP 300 Series User Guide
Comprehensive user guide for the Extron SMP 300 Series, covering installation, configuration, and operation of the SMP 351, SMP 351 3G-SDI, SMP 352, and SMP 352 3G-SDI streaming media processors. Learn about features, connectivity, front panel and web-based interface operation, troubleshooting, and advanced capabilities.