1. Important Safety Instructions
Please read all instructions carefully before using the dehumidifier and retain this manual for future reference. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Always place the dehumidifier on a stable, level surface.
- Ensure the power supply matches the voltage specified on the rating label.
- Do not operate the unit with a damaged cord or plug. If the cord is damaged, it must be replaced by the manufacturer or a qualified service agent.
- Keep the appliance at least 20 cm (8 inches) away from walls or other objects to ensure proper airflow.
- Do not insert objects into the air inlet or outlet.
- Do not use the dehumidifier in areas where flammable gases or liquids are stored.
- Unplug the unit before cleaning, maintenance, or when not in use for extended periods.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance.
2. Product Overview
The CONOPU DH-CS13 Dehumidifier utilizes dual semiconductor technology to efficiently remove moisture from the air, creating a healthier and more comfortable indoor environment. It features a large water tank, multiple operating modes, and automatic functions for user convenience.
Package Contents:
- CONOPU DH-CS13 Dehumidifier
- Power Adapter
- User Manual
Component Identification:
- Control Panel: Located on the top, with buttons for Power, Mode, Lights, Timer, and Defrost.
- Air Inlet: Located on the back/sides.
- Air Outlet: Located on the top.
- Water Tank: 3000ml capacity, transparent window, located at the bottom front/side for easy removal.
- Handle: Integrated side handles for portability.


3. Setup
3.1 Unpacking
- Carefully remove the dehumidifier from its packaging.
- Remove all packing materials, including any protective films or tapes.
- Inspect the unit for any signs of damage. If damaged, do not operate and contact customer support.
3.2 Placement
Proper placement is crucial for optimal performance.
- Place the dehumidifier in a room where humidity control is desired. It is suitable for rooms between 5 m² and 30 m².
- Ensure there is at least 20 cm (8 inches) of clear space around the air inlet and outlet to allow for unrestricted airflow. Avoid placing it directly against walls, furniture, or curtains.
- Operate the unit in an environment with temperatures between 15°C and 40°C for best results.
- Close all doors and windows in the room to maximize dehumidification efficiency.

3.3 Power Connection
Connect the power adapter to the dehumidifier's power port, then plug the adapter into a suitable electrical outlet. The unit will enter standby mode.
4. Operating Instructions
4.1 Power On/Off
Press the Power button on the control panel to turn the dehumidifier ON or OFF.
4.2 Operating Modes
Press the Mode button to cycle through the available operating modes:
- Manual Mode (L1/L2): This mode offers two fan speeds for different dehumidification needs.
- L1 (Standard): For gentle operation and maintaining low humidity levels.
- L2 (Strong): For rapid and efficient dehumidification in higher humidity conditions.
- Night Mode: Designed for quiet operation (approximately 33 dB) for undisturbed sleep. The indicator lights are dimmed or turned off in this mode.

4.3 Timer Function
Press the Timer button to set the operating duration. You can choose between 6, 12, or 24 hours. The unit will automatically turn off once the set time has elapsed.
4.4 Automatic Defrost
The dehumidifier is equipped with an automatic defrost function. If frost builds up on the internal components in colder environments, the unit will automatically activate defrosting to maintain optimal performance and protect the appliance. This ensures continuous operation even in low temperatures.

4.5 Water Tank Full & Auto Shut-off
The dehumidifier will automatically shut off when the 3000ml water tank is full to prevent overflow. An indicator light will illuminate to signal that the tank needs to be emptied. The unit will resume operation once the tank is emptied and reinserted correctly.

5. Maintenance
Regular maintenance ensures the longevity and efficiency of your dehumidifier.
5.1 Emptying the Water Tank
- When the water tank is full, the dehumidifier will stop operating and the full tank indicator will light up.
- Carefully pull out the water tank from the unit. The transparent window allows you to monitor the water level.
- Pour out the collected water.
- Slide the empty water tank back into the dehumidifier until it clicks into place. Ensure it is properly seated to allow the unit to resume operation.

5.2 Cleaning the Unit
- Exterior: Wipe the exterior of the dehumidifier with a soft, damp cloth. Do not use abrasive cleaners or solvents.
- Air Inlet/Outlet: Use a soft brush or vacuum cleaner attachment to gently remove any dust or debris from the air inlet and outlet grilles.
- Water Tank: Clean the water tank regularly with mild soap and water to prevent mold or mildew growth. Rinse thoroughly before reinserting.
6. Troubleshooting
If you encounter issues with your dehumidifier, please refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Dehumidifier does not turn on. | No power supply. Power button not pressed. | Ensure the power adapter is securely plugged into the unit and a working electrical outlet. Press the Power button. |
| Unit is running but not collecting water. | Room humidity is too low. Room temperature is too low (below 15°C). Air inlets/outlets are blocked. | Dehumidifier will only collect water if humidity is above 40-50%. Ensure operating temperature is within 15°C - 40°C. Clear any obstructions from the air inlets and outlets. |
| Unit stops operating and indicator light is on. | Water tank is full. Water tank is not properly inserted. | Empty the water tank. Reinsert the water tank correctly until it clicks into place. |
| Unit is noisy. | Unit is on an uneven surface. Air inlets/outlets are blocked. | Place the dehumidifier on a flat, stable surface. Clear any obstructions from the air inlets and outlets. |
| Frost appears on internal components. | Operating in a cold environment. | This is normal. The automatic defrost function will activate to remove the frost. No user action is required. |
If the problem persists after trying these solutions, please contact customer support.
7. Specifications
| Brand | CONOPU |
| Model Number | DH-CS13 |
| Dimensions (L x W x H) | 17.5 x 33.5 x 27.5 cm |
| Weight | 3.06 kg |
| Water Tank Capacity | 3000 ml |
| Dehumidification Capacity | Up to 800 ml/24 hours (at 30°C, 80% RH) |
| Power Consumption | Approx. 1.3 kWh/day |
| Noise Level (Night Mode) | Approx. 33 dB |
| Recommended Room Size | 5 - 30 m² |
| Operating Temperature Range | 15°C - 40°C |
| Special Features | Automatic Defrost, Auto Shut-off, 24h Timer, Dual Semiconductor Technology |