1. Safety Information
Please read and understand all safety warnings and instructions before installing, operating, or performing maintenance on this pool pump. Failure to follow these instructions could result in serious injury or death.
- Electrical Safety: Always disconnect power to the pump before performing any service or maintenance. Ensure proper grounding and use a Ground Fault Circuit Interrupter (GFCI) for electrical connections. All wiring should be performed by a qualified electrician and comply with local and national electrical codes.
- Water Safety: Do not run the pump dry. Ensure the pump is properly primed with water before starting to prevent damage.
- Installation: Install the pump in a well-ventilated area, protected from direct sunlight and extreme weather conditions. Maintain adequate clearance around the pump for air circulation and service access.
- Children: Keep children away from the pump and all pool equipment.
- Thermal Overload Protection: The pump features built-in automatic thermal overload protection to prevent motor overheating and burning out.
2. Product Overview
The Vidapool SPT100-LV is a high-performance, self-priming pool pump designed for both in-ground and above-ground swimming pools. It ensures efficient water circulation and filtration, contributing to a clean and clear swimming environment.
Key Features:
- High Flow Rate: 1HP motor with 5860 GPH (Gallons Per Hour) flow rate.
- Integrated Timer: Customizable run-time options from 2 to 24 hours, activating automatically daily.
- Quiet Operation: Engineered for stability and ultra-low noise performance.
- Easy Installation: Designed for straightforward setup with included adapters.
- Advanced Filtration: Large filter basket efficiently collects debris, leaves, and coarse particles.
- Safety: Built-in automatic thermal overload protection and a 6-foot UL-tested cord.
Components:
Refer to the image below for a visual representation of the pump's components.

Figure 1: Vidapool Pool Pump Components
- 1.5" ID Adapters
- 2" ID Adapters
- Filter Basket
- Drain Plug
- Pure copper Motor
- 6' Power Cord
- Earthing Terminal
- Timer
- Lid Opener
3. Specifications
| Specification | Value |
|---|---|
| Brand | Vidapool |
| Model Number | SPT100-LV |
| Power Source | Corded Electric |
| Voltage | 115 Volts |
| Horsepower (HP) | 1 HP |
| Maximum Flow Rate | 97 Gallons Per Minute (5860 GPH) |
| Maximum Lifting Height | 50 Feet |
| Item Weight | 13 Pounds |
| Product Dimensions (L x W x H) | 8"L x 11"W x 23"H |
| Material | Cast Iron, Plastic |
| Included Components | Pool pump, 1.25-inch and 1.5-inch inlet/outlet adapters |
For detailed flow rate at various total heads, refer to the table below:

Figure 2: Detailed Pump Specifications and Flow Rates
4. Setup & Installation
The Vidapool pool pump is designed for easy installation. Follow these steps for proper setup:
4.1 Unpacking and Inspection
- Carefully remove all components from the packaging.
- Inspect the pump for any signs of damage during shipping. Contact customer support immediately if any damage is found.
- Ensure all listed components are present: pump unit, 1.25-inch adapters (2), 1.5-inch adapters (2), lid opener.
4.2 Placement
- Place the pump on a solid, level surface near the pool.
- Ensure the location is well-ventilated and protected from rain and direct sunlight.
- Maintain sufficient space around the pump for maintenance and air circulation.
4.3 Plumbing Connections
The pump comes with two 1.25-inch and two 1.5-inch inlet and outlet adapters, compatible with Schedule 40 PVC pipe. Choose the appropriate adapters for your plumbing system.

Figure 3: Outlet/Inlet Connection Methods
- Method 1: 1-1/2" or 2" Schedule 40 PVC Pipe Glue Connection. Use PVC cement to securely attach the appropriate PVC pipe directly to the pump's inlet and outlet ports.
- Method 2: 1-1/2" or 2" Schedule 40 PVC Pipe Glue Connection + 2" PVC Hose with Clamp. For flexible hose connections, first glue the PVC pipe to the pump, then attach the PVC hose using a hose clamp.
- Ensure all connections are watertight to prevent leaks and maintain pump efficiency.
4.4 Electrical Connection
- The pump operates on 115V. Ensure your power supply matches this requirement.
- Plug the 6-foot UL-tested power cord into a properly grounded GFCI-protected outlet.
- Ensure the earthing terminal is correctly connected for safety.

Figure 4: Safe UL Cord Connection
5. Operating Instructions
5.1 Priming the Pump
Before starting the pump for the first time or after draining, it must be primed:
- Ensure all valves are open to allow water flow to the pump.
- Remove the lid of the filter basket (use the included lid opener if needed).
- Fill the filter basket with water until it overflows.
- Replace the lid securely.
- Turn on the pump. It should begin to draw water and circulate it. If it does not prime within a few minutes, turn it off, re-fill the basket, and try again.
5.2 Setting the Integrated Timer
The pump features an integrated timer for automated operation. Do not operate the pump when the priming system is closed.

Figure 5: Setting the Pump Timer
- Step 1: Calculate Run Time. Determine the optimal pump run time based on your pool size and usage. The timer offers nine options from 2 to 24 hours.
- Step 2: Set Start Time. Wait until the desired time you want the pump to start each day.
- Step 3: Select Running Hours. Press the clock button on the control panel to choose the desired running hours.
- The pump will now automatically activate at the set time every day and run for the selected duration.
5.3 Quiet Operation
The pump is designed for quiet performance, allowing for a peaceful poolside experience even during operation.

Figure 6: Continuous Duty Motor for Quiet Operation
6. Maintenance
Regular maintenance ensures optimal performance and longevity of your Vidapool pump.
6.1 Cleaning the Filter Basket
The large filter basket collects debris and requires periodic cleaning.

Figure 7: Detachable Filter Basket Design
- Disconnect Power: Always turn off and unplug the pump before cleaning.
- Remove Lid: Use the lid opener to unscrew and remove the transparent lid.
- Remove Basket: Carefully lift out the filter basket.
- Clean Debris: Empty any collected leaves, hair, grit, or other debris from the basket. Rinse the basket thoroughly with water.
- Reinstall: Place the clean basket back into the pump, ensuring it is seated correctly. Replace the lid and tighten it securely.
6.2 Winterization
If you live in an area with freezing temperatures, proper winterization is crucial to prevent damage:
- Drain all water from the pump and plumbing lines.
- Disconnect the pump and store it in a dry, frost-free location.
- Follow your pool manufacturer's guidelines for winterizing the entire pool system.
7. Troubleshooting
This section provides solutions to common issues you might encounter with your pool pump.
| Problem | Possible Cause | Solution |
|---|---|---|
| Pump does not start | No power; tripped GFCI; motor overload; faulty wiring | Check power supply; reset GFCI; allow motor to cool; inspect wiring (consult electrician) |
| Pump runs but no water flow | Pump not primed; clogged filter basket; closed valves; air leak in suction line | Prime the pump; clean filter basket; open all valves; check for and seal air leaks |
| Low water flow | Clogged filter basket; partially closed valves; dirty filter; undersized plumbing | Clean filter basket; ensure valves are fully open; clean or backwash pool filter; consult a professional for plumbing assessment |
| Excessive noise or vibration | Air leak in suction line; pump not securely mounted; worn bearings; cavitation | Check for and seal air leaks; ensure pump is securely mounted; contact customer support for worn parts; ensure adequate water supply to pump |
| Water leaking from pump | Loose connections; damaged O-rings or seals; cracked housing | Tighten connections; replace O-rings/seals; contact customer support for cracked housing |
If you encounter an issue not listed here or if the suggested solutions do not resolve the problem, please contact Vidapool customer support.
8. Pump Selection Tips
Choosing the right pump size for your pool is essential for efficient circulation and filtration. Consider your pool's shape and volume when selecting a pump.
8.1 Oval Pools

Figure 8: Oval Pool Pump Selection Guide
8.2 Rectangular Pools

Figure 9: Rectangular Pool Pump Selection Guide
8.3 Round Pools

Figure 10: Round Pool Pump Selection Guide
8.4 Kidney-Shaped Pools

Figure 11: Kidney-Shaped Pool Pump Selection Guide
9. Warranty & Support
The Vidapool SPT100-LV In/Above Ground Pool Pump is backed by a two-year warranty. This warranty covers defects in materials and workmanship under normal use and service.
For warranty claims, technical assistance, or any questions regarding your product, please contact Vidapool customer support. Ensure you have your model number (SPT100-LV) and proof of purchase available when contacting support.