Livpure Magnakool 36L

Livpure Magnakool Tower 36L Air Cooler User Manual

Model: Magnakool 36L | Brand: Livpure

1. Introduction

Thank you for choosing the Livpure Magnakool Tower 36L Air Cooler. This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your new appliance. Please read it thoroughly before use and retain it for future reference.

What's in the Box:

  • Livpure Magnakool Tower 36L Air Cooler Unit
  • User Manual (this document)
  • Wheels (for assembly)
Livpure Magnakool Tower 36L Air Cooler front view

Figure 1: Livpure Magnakool Tower 36L Air Cooler. This image shows the overall design of the air cooler unit.

2. Safety Instructions

Always follow basic safety precautions when using electrical appliances to reduce the risk of fire, electric shock, and injury.

  • Ensure the power supply voltage matches the rating label on the cooler.
  • Do not operate the cooler with a damaged cord or plug.
  • Keep the cooler away from water sources and do not immerse it in water.
  • Unplug the cooler before cleaning, refilling water, or performing any maintenance.
  • Do not block air inlets or outlets.
  • Keep children and pets away from the cooler during operation.
  • Place the cooler on a stable, level surface to prevent tipping.
  • Do not use the cooler in areas with flammable liquids or gases.

3. Setup and Installation

3.1 Unpacking

  1. Carefully remove the air cooler from its packaging.
  2. Check for any damage during transit. Contact customer support if any damage is found.
  3. Remove all packing materials, including any protective films or tapes.

3.2 Attaching Wheels

The cooler comes with multidirectional wheels for easy mobility. Follow these steps to attach them:

  1. Carefully tilt the cooler to access the bottom. It is recommended to have assistance.
  2. Insert the stem of each wheel into the designated slots on the base of the cooler.
  3. Push firmly until each wheel clicks securely into place.
  4. Return the cooler to an upright position.
Livpure Magnakool Tower 36L Air Cooler side view with wheels

Figure 2: Side view of the cooler, illustrating the attached multidirectional wheels for easy movement.

3.3 Placement

  • Place the air cooler on a firm, level surface.
  • Ensure there is adequate space around the cooler for proper airflow (at least 15-20 cm from walls or furniture).
  • For optimal cooling, position the cooler near an open window or door to allow fresh air intake and exhaust of humid air.
  • The cooler is designed for 188 Sq.Ft. large area coverage.

3.4 Water Filling

  1. Locate the water inlet on the cooler.
  2. Fill the 36L reservoir with clean, fresh water. Do not overfill beyond the 'MAX' indicator.
  3. For enhanced cooling, open the ice chamber and add ice cubes or ice packs.
  4. Close the water inlet and ice chamber securely.

4. Operating Instructions

The Livpure Magnakool Tower 36L Air Cooler features simple knob controls for ease of use.

4.1 Control Panel

Livpure Magnakool Tower 36L Air Cooler control knobs

Figure 3: Close-up of the control knobs on the top panel of the air cooler.

The cooler is equipped with knob controls for various functions:

  • Fan Speed Knob: Adjusts the fan speed (Low, Medium, High). The cooler has 3 speeds.
  • Cooling/Pump Knob: Activates or deactivates the water pump for evaporative cooling.
  • Swing Knob: Controls the motorized vertical louvers for automatic oscillation, distributing air across a wider area.

4.2 Starting the Cooler

  1. Ensure the water tank is filled and the cooler is plugged into a suitable power outlet (220 Volts AC).
  2. Turn the Fan Speed Knob to your desired setting (Low, Medium, or High). The fan will start operating.
  3. To activate cooling, turn the Cooling/Pump Knob to the 'ON' position. The water pump will start circulating water over the honeycomb pads.
  4. To enable air oscillation, turn the Swing Knob to the 'ON' position. The motorized vertical louvers will begin to move.

4.3 Key Features

  • Anti-bacterial Honeycomb Pads: These pads are designed to ensure clean and hygienic air circulation, reducing airborne contaminants.
  • Ice Chamber: A dedicated compartment for ice cubes or ice packs to enhance cooling efficiency.
  • Motorized Vertical Louvers: Provides customized air direction and distribution for optimal comfort.
  • High Speed Air Delivery: Capable of delivering 1600 Cubic Feet Per Minute (CFM) of air.
  • Inverter Compatible: Can operate with home inverters during power outages.

5. Maintenance

Regular maintenance ensures optimal performance and longevity of your air cooler.

5.1 Cleaning the Water Tank

It is recommended to clean the water tank weekly to prevent algae growth and maintain hygiene.

  1. Unplug the cooler from the power outlet.
  2. Drain any remaining water from the tank.
  3. Wipe the inside of the tank with a soft cloth and mild detergent.
  4. Rinse thoroughly with clean water to remove all detergent residue.
  5. Allow the tank to air dry before refilling.

5.2 Cleaning/Replacing Honeycomb Pads

The anti-bacterial honeycomb pads should be cleaned periodically, or replaced if heavily soiled or damaged.

  1. Unplug the cooler.
  2. Carefully remove the back panel or access door to expose the honeycomb pads.
  3. Gently remove the pads.
  4. Rinse the pads under running water to remove dust and mineral deposits. Do not use harsh chemicals.
  5. If pads are heavily soiled or damaged, replace them with genuine Livpure spare parts.
  6. Reinstall the clean or new pads and secure the back panel.
Livpure Magnakool Tower 36L Air Cooler with honeycomb pads highlighted

Figure 4: Illustration highlighting the honeycomb pads within the air cooler.

5.3 Exterior Cleaning

  • Wipe the exterior of the cooler with a soft, damp cloth.
  • Do not use abrasive cleaners or solvents.
  • Ensure no water enters the control panel or electrical components.

6. Troubleshooting

If you encounter any issues with your Livpure Magnakool Tower 36L Air Cooler, refer to the following table for common problems and solutions.

ProblemPossible CauseSolution
Cooler does not turn onNo power supply; Power cord not plugged in; Fuse blownCheck power outlet; Ensure cord is securely plugged in; Check household fuse/breaker.
No cooling effectWater tank empty; Pump not activated; Honeycomb pads cloggedFill water tank; Turn on Cooling/Pump knob; Clean or replace honeycomb pads.
Weak airflowFan speed too low; Air inlets/outlets blocked; Dirty fan bladesIncrease fan speed; Clear obstructions; Clean fan blades (with caution, unplugged).
Unpleasant odorStagnant water; Dirty honeycomb padsDrain and clean water tank; Clean or replace honeycomb pads.
Water leakageOverfilled water tank; Cooler not level; Damaged water pump/hoseDo not overfill; Place on a level surface; Contact customer support for inspection.

If the problem persists after attempting these solutions, please contact Livpure customer support.

7. Specifications

Detailed technical specifications for the Livpure Magnakool Tower 36L Air Cooler.

FeatureSpecification
BrandLivpure
Model NameMagnakool - 36 L
MaterialPlastic
Mounting TypeFreestanding
Special FeaturesAdjustable Speed, Built-In Wheel, Portable
ColourWhite & Blue
Air Flow Capacity1600 Cubic Feet Per Minute
Controls TypeKnob
Reservoir Capacity36 Liters
Floor Area Coverage188 Square Feet
Item Weight11.3 Kilograms
Recommended UsesResidential
Form FactorTower
Wattage100 Watts
Noise Level58 Decibels
Number Of Speeds3
Voltage220 Volts (AC)
Item Dimensions (D x W x H)36D x 35W x 103.5H Centimeters
Manufacture Year2024

8. Warranty and Support

8.1 Warranty Information

Your Livpure Magnakool Tower 36L Air Cooler comes with a 1 Year comprehensive Warranty and 2 Years on Fan motor from the date of purchase. Please retain your purchase receipt as proof of warranty.

The warranty covers manufacturing defects under normal use. It does not cover damage caused by misuse, accident, unauthorized modification, or improper installation.

8.2 Customer Support

For any queries, technical assistance, or warranty claims, please contact Livpure customer support. Refer to the contact information provided with your product packaging or visit the official Livpure website.

Manufacturer: Livpure Pvt. Ltd. Plot No. 221, Udyog Vihar, Phase 1, Gurgaon - 122016

© 2024 Livpure. All rights reserved.

Ask a question about this manual