GOLDEN BLUE AP01

GOLDEN BLUE AP01 Digital Thermohygrometer Electronic Clock User Manual

1. Introduction

Thank you for choosing the GOLDEN BLUE AP01 Digital Thermohygrometer Electronic Clock. This device is designed to provide accurate real-time measurements of indoor temperature and humidity, along with essential clock and alarm functions. Please read this manual carefully to ensure proper use and optimal performance of your device.

2. Product Overview

2.1 Key Features

  • Real-time temperature and humidity display.
  • 24-hour clock system with hourly reporting function.
  • Alarm clock with snooze function.
  • Date display with week indication.
  • Environmental climate comfort reminder (Dry, Comfortable, Humid).
  • High-definition LCD screen for clear readability.

2.2 Package Contents

  • GOLDEN BLUE AP01 Digital Thermohygrometer Electronic Clock
  • User Manual

2.3 Device Layout

Familiarize yourself with the various parts of your AP01 device:

Diagram of GOLDEN BLUE AP01 Thermohygrometer with numbered parts

Image 1: Front and back view of the AP01 device with numbered components. This diagram illustrates the location of buttons, sensors, and other features for easy identification.

  1. Real-time temperature display
  2. Real-time humidity display
  3. Comfort level indicator
  4. Real-time clock display
  5. Hourly report indicator
  6. Alarm clock indicator
  7. Calendar display
  8. Week display
  9. Power switch / Setting button (Long press to switch power, single press to adjust value/confirm)
  10. Alarm clock mode button (Switch alarm on/off, adjust value, turn off alarm)
  11. Mode switch / Confirm button (Single press to switch clock/alarm mode, long press to enter settings)
  12. Wall hanging hole
  13. Shrink support frame
  14. Battery cabin cover
  15. Charging indicator light (Red: charging, Green: fully charged)

3. Setup

3.1 Battery Installation

The AP01 operates on battery power. To install or replace batteries:

  1. Locate the battery cabin cover (14) on the back of the device.
  2. Open the cover.
  3. Insert the required batteries, ensuring correct polarity (+/-).
  4. Close the battery cabin cover securely.

3.2 Initial Power On

After battery installation, the device should power on automatically. If not, long press the power switch (9) to turn it on.

3.3 Time and Date Setting

To set the time and date:

  1. In clock mode, long press the Mode switch / Confirm button (11) to enter the settings interface (clock/calendar/week).
  2. Use the Power switch / Setting button (9) to adjust the value (e.g., hour, minute, year, month, day).
  3. Press the Mode switch / Confirm button (11) to confirm the setting and move to the next parameter.
  4. Repeat until all parameters are set. The device will automatically exit setting mode after a period of inactivity or after setting the last parameter.

4. Operating Instructions

4.1 Display Information

The high-definition LCD screen displays various information simultaneously:

Front view of GOLDEN BLUE AP01 Thermohygrometer displaying temperature, humidity, time, and comfort levels

Image 2: The main display of the AP01 showing current temperature, humidity percentage, time, date, and the comfort level indicator at the bottom.

  • Temperature: Shown in degrees Celsius or Fahrenheit (user selectable, refer to settings).
  • Humidity: Displayed as a percentage (%).
  • Time: Current time in 24-hour format.
  • Date & Week: Current date and day of the week.
  • Comfort Level: Indicates environmental comfort as Dry, Comfortable, or Humid.
GOLDEN BLUE AP01 Thermohygrometer showing real-time detection of temperature, humidity, date, and alarm

Image 3: The AP01 device highlighting its real-time detection capabilities for temperature, humidity, date, and alarm status.

4.2 Temperature and Humidity Monitoring

The device continuously monitors and displays the ambient temperature and humidity. Readings are updated every 10 seconds.

  • Temperature Range: -10°C to 50°C (14°F to 122°F). Readings below -10°C will show 'LLL', and above 50°C will show 'HHH'.
  • Humidity Range: 10% to 99% RH.

4.3 Alarm Clock Function

To set and use the alarm clock:

  1. Single press the Mode switch / Confirm button (11) to switch to alarm clock mode. The alarm time will be displayed.
  2. Long press the Alarm clock mode button (10) to enter alarm setting.
  3. Use the Power switch / Setting button (9) to adjust the alarm hour and minute.
  4. Press the Alarm clock mode button (10) to confirm each setting.
  5. To turn the alarm on or off, single press the Alarm clock mode button (10) while in alarm mode. An alarm icon will appear/disappear on the display.
  6. When the alarm sounds, press any button to activate the 5-minute snooze function. To turn off the alarm completely, press the Alarm clock mode button (10) during the alarm sound.

4.4 Hourly Report Function

The device can be set to provide an hourly audio report.

GOLDEN BLUE AP01 Thermohygrometer showing hourly report function and back hanging hole

Image 4: The AP01 device illustrating the hourly report function and the physical back hanging hole for wall mounting.

  • To turn the hourly report on or off, single press the Power switch / Setting button (9) while in clock mode. An icon (e.g., a bell or speaker) will indicate if the hourly report is active.

4.5 Comfort Level Indicator

The device provides a visual indicator for environmental comfort based on temperature and humidity levels:

  • DRY: Indicates low humidity.
  • COMFORT: Indicates optimal temperature and humidity levels.
  • WET: Indicates high humidity.

5. Maintenance

5.1 Cleaning

To clean the device, wipe it gently with a soft, dry cloth. Do not use abrasive cleaners, solvents, or immerse the device in water.

5.2 Battery Replacement

When the display becomes dim or the device functions erratically, it is time to replace the batteries. Follow the instructions in Section 3.1.

5.3 Storage

If the device will not be used for an extended period, remove the batteries to prevent leakage and store it in a cool, dry place.

6. Troubleshooting

  • No display or dim display:
        - Check battery installation and polarity.
        - Replace batteries if they are low.
  • Incorrect temperature/humidity readings:
        - Ensure the device is not placed near heat sources, direct sunlight, or in areas with extreme drafts.
        - Allow the device to stabilize for 15-30 minutes after initial setup or relocation.
  • Alarm not sounding:
        - Verify that the alarm function is enabled (alarm icon visible on display).
        - Check alarm time settings.
  • 'LLL' or 'HHH' displayed for temperature:
        - The temperature is outside the measurable range (-10°C to 50°C). Move the device to an environment within this range.

7. Specifications

7.1 Technical Specifications

Working Temperature0°C to 50°C (32°F to 122°F)
Display ScreenLCD Display
Temperature Measurement Range-10°C to 50°C (14°F to 122°F)
Temperature Measurement Error±1°C
Humidity Measurement Range10% to 99% RH
Humidity Measurement Error±5% RH (40%~80%), ±8% RH (other ranges)
Detection Cycle10 seconds
Power SourceBattery

7.2 Dimensions

The physical dimensions of the AP01 device are as follows:

GOLDEN BLUE AP01 Thermohygrometer with dimensions labeled: 7cm/2.78inch height, 8.7cm/3.45inch width, 2cm/0.86inch depth

Image 5: The AP01 device with its dimensions clearly marked: 7cm (2.78 inches) in height, 8.7cm (3.45 inches) in width, and 2cm (0.86 inches) in depth.

  • Height: 7 cm (2.78 inches)
  • Width: 8.7 cm (3.45 inches)
  • Depth: 2 cm (0.86 inches)

8. Warranty and Support

This product is covered by a standard manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation provided at the time of purchase or contact your retailer.

For technical support, troubleshooting assistance, or inquiries regarding your GOLDEN BLUE AP01 device, please contact the seller or refer to the official GOLDEN BLUE website for further resources.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.