ALORAIR Storm 80X

ALORAIR Storm 80X Commercial Dehumidifier User Manual

Model: Storm 80X

1. Product Overview

The ALORAIR Storm 80X is a commercial-grade dehumidifier designed for efficient moisture removal in large spaces up to 2,100 square feet. It is capable of removing up to 170 pints of water per day at saturation (90°F, 90% RH) and 80 PPD at AHAM conditions. This unit features a robust rotomolded housing for durability, a built-in condensate pump for continuous drainage, and an intuitive control panel for easy operation.

ALORAIR Storm 80X Commercial Dehumidifier

Figure 1: ALORAIR Storm 80X Dehumidifier with retractable handle.

Key Features:

2. Important Safety Information

Read all instructions carefully before operating the dehumidifier. Failure to follow these instructions may result in electric shock, fire, or serious injury.

3. Setup and Installation

3.1 Unpacking the Unit

Carefully remove the dehumidifier from its packaging. Inspect the unit for any signs of damage during transit. Retain packaging materials for future storage or transport.

Video 1: Unboxing and initial setup of the ALORAIR Storm 80X Dehumidifier.

3.2 Handle Assembly

The retractable handle is designed for easy mobility. To extend the handle, loosen the two knobs on the sides, pull the handle upwards, and then tighten the knobs to secure it in place. To retract, reverse the process.

Person pulling ALORAIR Storm 80X Dehumidifier with handle and wheels

Figure 2: The retractable handle and large wheels facilitate easy movement of the unit.

3.3 Drain Hose Connection

Connect the provided 19.6 ft drain hose to the quick-connect fitting at the bottom rear of the unit. Ensure a secure connection to prevent leaks. Route the hose to a suitable drainage point, such as a floor drain or sink, ensuring the hose is not kinked or obstructed. The built-in pump can lift water up to 19.6 feet vertically.

ALORAIR Storm 80X Dehumidifier with drain hose and pump drainage height indicated

Figure 3: Drain hose connection and pump drainage height capability.

3.4 Power Connection

Plug the dehumidifier into a standard 115V grounded electrical outlet. The power cord can be neatly coiled and stored on the back of the unit when not in use or for transport.

ALORAIR Storm 80X Dehumidifier showing convenient cord and hose storage on the back

Figure 4: Rear view of the dehumidifier showing integrated cord and hose storage.

4. Operating Instructions

4.1 Control Panel Overview

The Storm 80X features an intelligent touch control panel. It displays real-time inlet and outlet temperature, humidity, job hours, and total life hours. Buttons include Power, Purge, Menu, and Set.

Close-up of ALORAIR Storm 80X control panel showing display and buttons

Figure 5: Detailed view of the intelligent touch control panel.

Video 2: Demonstration of the control panel and its functions.

4.2 Setting Desired Humidity

  1. Press the 'Set' button to enter humidity adjustment mode.
  2. Use the arrow buttons to increase or decrease the desired humidity percentage (25% to 80%).
  3. The unit will automatically operate to maintain the set humidity level.

4.3 Continuous Mode

To operate the dehumidifier continuously, set the humidity level to 'CO%' (Continuous Mode) using the 'Set' and arrow buttons. In this mode, the unit will run constantly, removing moisture without stopping based on a set humidity level.

4.4 Automatic Features

5. Maintenance

Regular maintenance ensures optimal performance and extends the lifespan of your ALORAIR Storm 80X dehumidifier.

5.1 MERV-1 Filter Cleaning/Replacement

The unit is equipped with a washable MERV-1 filter. It is recommended to clean the filter every three months or more frequently depending on usage and environment. Replace the filter after two cleanings or as needed.

  1. Disconnect the unit from power.
  2. Locate the filter access panel on the front of the unit.
  3. Remove the filter.
  4. Clean the filter with warm water and mild detergent, or vacuum it. Allow it to dry completely before reinstallation.
  5. Reinsert the clean filter and secure the access panel.

Video 3: Instructions for replacing the MERV-1 filter.

5.2 Drain System Maintenance

Periodically check the drain hose for any blockages or kinks. Ensure the condensate pump is functioning correctly by observing water flow during operation. The 'Purge' button on the control panel can be used to manually activate the pump and clear any residual water.

6. Troubleshooting

If the unit is not operating correctly, refer to the following common issues before contacting support.

ProblemPossible CauseSolution
Unit does not turn onNo power, power cord disconnected, circuit breaker tripped.Check power connection, ensure outlet is functional, reset circuit breaker.
No dehumidificationHumidity setting too high, filter clogged, room temperature too low.Lower humidity setpoint, clean/replace filter, ensure room temperature is within operating range (35.6°F - 102.2°F).
Water leakageDrain hose kinked or clogged, drain connection loose.Inspect and clear drain hose, ensure secure connection.
Unit is noisyUnit not on a level surface, fan obstruction.Place unit on a level surface, check for and remove any obstructions.
Error code on displayInternal malfunction detected.Refer to the full user manual for specific error code definitions or contact customer support.

7. Specifications

FeatureSpecification
BrandALORAIR
Model NameStorm 80X
Dehumidification Capacity (Saturation)170 Pints per Day
Dehumidification Capacity (AHAM)80 PPD
Coverage AreaUp to 2,100 Square Feet
Air Flow Capacity200 Cubic Feet Per Minute (CFM)
Operating Temperature Range35.6°F - 102.2°F
Operating Humidity Range25% - 80% RH
Power Consumption607 Watts
Product Dimensions (L×W×H)15.2"D x 14.4"W x 24.8"H
Item Weight63.9 Pounds
Drain Hose Length19.6 ft
Drain Vertical Height19.6 ft
Filter TypeMERV-1
CertificationsETL Listed

8. Warranty and Support

ALORAIR provides a comprehensive warranty for the Storm 80X dehumidifier:

For additional warranty information or technical support, please refer to the full product user manual or contact ALORAIR customer service.

Related Documents - Storm 80X

PreviewALORAIR Storm DP Dehumidifier Owner's Manual - Operation, Features, Specifications, and Maintenance
Comprehensive owner's manual for the ALORAIR Storm DP Dehumidifier. This guide covers product features, detailed specifications, operating instructions, troubleshooting common issues, and maintenance procedures for optimal performance.
PreviewAlorAir Galaxy 85P Dehumidifier: Features, Specifications, and Applications
Discover the AlorAir Galaxy 85P Dehumidifier, a powerful and compact solution for moisture control in residential and commercial spaces. Learn about its features, specifications, performance, and applications.
PreviewAlorAir Storm Dehumidifier Installation and Operations Manual
This manual provides detailed instructions for the AlorAir Storm SLGR 850X, Storm LGR 850X, and Storm LGR 850 dehumidifiers, covering safety, operation, maintenance, troubleshooting, and warranty information.
PreviewAlorair Storm LGR Extreme Dehumidifier: Installation and Operations Manual
Comprehensive guide for the Alorair Storm LGR Extreme dehumidifier, covering installation, operation, maintenance, troubleshooting, error codes, and warranty information.
PreviewAlorAir Storm SLGR 1250X Installation and Operations Manual
This manual provides comprehensive installation, operation, maintenance, and troubleshooting guidance for the AlorAir Storm SLGR 1250X dehumidifier. It covers safety instructions, electrical supply, unit functionality, parts identification, LCD display usage, and warranty information.
PreviewALORAIR Storm DP Dehumidifier Owner's Manual - Features, Specs, Operation & Maintenance
Comprehensive owner's manual for the ALORAIR Storm DP Dehumidifier. Covers features, specifications, operation guidelines, troubleshooting, maintenance procedures, and limited warranty information.