ET2 E24716-144GLD

Download PDFFree PDF. The Save button below keeps a bookmark and private notes in your account.

ET2 Manta E24716-144GLD LED Linear Pendant Light Instruction Manual

Model: E24716-144GLD

1. Introduction

This manual provides detailed instructions for the safe installation, operation, and maintenance of your ET2 Manta E24716-144GLD LED Linear Pendant Light. Please read this manual thoroughly before proceeding with installation or use, and retain it for future reference.

The ET2 Manta pendant light features an undulating design crafted from transparent acrylic with a frosted band and patterned etching, designed to provide warm, efficient LED illumination.

2. Safety Information

WARNING: Risk of electric shock. Disconnect power at the fuse box or circuit breaker before installation or servicing.

  • All electrical connections must be in accordance with local codes, ordinances, or the National Electric Code (NEC). Consult a qualified electrician if you are unfamiliar with proper electrical wiring connections.
  • This fixture is intended for indoor use only. Do not expose to water or moisture.
  • Ensure the mounting surface can support the weight of the fixture.
  • Do not attempt to modify the fixture. Any modifications may void the warranty and create a safety hazard.
  • Handle the acrylic components with care to prevent scratches or damage.

3. Package Contents

Verify that all components are present and undamaged before beginning installation.

  • ET2 Manta E24716-144GLD LED Linear Pendant Light Fixture
  • Mounting Hardware (e.g., canopy, mounting bracket, screws, wire nuts) - Specific components may vary.
  • Instruction Manual (this document)

4. Setup and Installation

This pendant light is designed for suspended installation. Professional installation by a qualified electrician is recommended.

  1. Turn Off Power: Before starting, ensure the power supply to the junction box is turned off at the circuit breaker or fuse box.
  2. Prepare Mounting Location: Securely attach the mounting bracket to the ceiling junction box. Ensure the bracket is firmly fixed and can support the fixture's weight (approximately 8 pounds).
  3. Adjust Suspension Wires: The pendant light is suspended by adjustable wires. Carefully adjust the length of the suspension wires to achieve the desired hanging height. Ensure both wires are of equal length for a level installation.
  4. Make Electrical Connections:
    • Connect the fixture's black wire to the supply circuit's black (Live) wire.
    • Connect the fixture's white wire to the supply circuit's white (Neutral) wire.
    • Connect the fixture's ground wire (bare copper or green) to the supply circuit's ground wire and the mounting bracket's ground screw.
    • Secure all connections with approved wire nuts and wrap with electrical tape.
  5. Secure Canopy: Carefully tuck all wires into the junction box and secure the fixture's canopy to the mounting bracket using the provided screws.
  6. Restore Power: Once installation is complete and all connections are secure, restore power at the circuit breaker.
ET2 Manta E24716-144GLD LED Linear Pendant Light, front view

Figure 1: Front view of the ET2 Manta E24716-144GLD LED Linear Pendant Light. This image shows the gold finish canopy and the undulating acrylic light panel suspended by thin wires.

5. Operating Instructions

The ET2 Manta E24716-144GLD LED Linear Pendant Light is designed for simple operation once installed.

  • Power On/Off: Operate the light using a standard wall switch connected to the fixture's power supply.
  • Light Output: The integrated LED light source provides 56 watts of warm white illumination (3000K color temperature) with a high Color Rendering Index (CRI) of 90 for accurate color representation.
  • Dimming: If connected to a compatible dimmer switch, the light output can be adjusted. Ensure any dimmer switch used is rated for LED fixtures.
ET2 Manta E24716-144GLD LED Linear Pendant Light, angled view showing detail

Figure 2: Angled view of the ET2 Manta E24716-144GLD pendant light, highlighting the textured surface of the acrylic panel and the polished gold finish of the canopy.

6. Maintenance

Regular cleaning will help maintain the appearance and performance of your pendant light.

  • Cleaning: Disconnect power before cleaning. Use a soft, dry, or slightly damp cloth to wipe the fixture. Do not use abrasive cleaners, solvents, or polishes as these can damage the finish and acrylic components.
  • Acrylic Care: The acrylic panel is delicate. Avoid harsh chemicals or rough materials that could scratch or cloud the surface.
  • LED Light Source: The integrated LED light source is designed for long life and is not user-replaceable. Do not attempt to replace the LEDs.
  • Water Resistance: This fixture is not water resistant and is intended for indoor, dry locations only. Avoid exposure to water or high humidity.

7. Troubleshooting

If you experience issues with your pendant light, refer to the following common troubleshooting steps:

Problem Possible Cause Solution
Light does not turn on.
  • No power to the fixture.
  • Loose wire connections.
  • Faulty wall switch.
  • Check circuit breaker/fuse.
  • Verify all electrical connections are secure (ensure power is off first).
  • Test the wall switch with another device or replace if faulty.
Light flickers or dims unexpectedly.
  • Incompatible dimmer switch.
  • Loose wiring.
  • Ensure dimmer is LED compatible.
  • Check electrical connections (power off).
Fixture is not level. Uneven suspension wire adjustment. Adjust suspension wire lengths until the fixture is level.

If these steps do not resolve the issue, contact a qualified electrician or ET2 customer support.

8. Specifications

Feature Detail
Model NumberE24716-144GLD
BrandET2
Product Dimensions (L x W x H)59" x 9.75" x 8.5"
Item Weight8 Pounds
MaterialAcrylic, Aluminum, Steel
Finish TypePolished Gold
Light Source TypeIntegrated LED
Wattage56 Watts
Voltage120 Volts (AC)
Light ColorWarm White (3000K)
Color Rendering Index (CRI)90
Number of Light Sources1
Installation TypeSuspended (Ceiling Mount)
Indoor/Outdoor UsageIndoor Only
Water Resistance LevelNot Water Resistant
Assembly RequiredNo (fixture comes pre-assembled)

9. Warranty Information

This ET2 Manta E24716-144GLD LED Linear Pendant Light is covered by a Manufacturer's Warranty. For specific terms, conditions, and duration of the warranty, please refer to the warranty documentation provided with your purchase or visit the official ET2 website.

Retain your proof of purchase for warranty claims.

10. Customer Support

For technical assistance, replacement parts, or further inquiries, please contact ET2 customer support.

You can find contact information and additional resources by visiting the official ET2 website or the ET2 store on Amazon: Visit the ET2 Store

© 2024 ET2 Lighting. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.