EASTMAN ENERGY EGT-10K.3P2M
Eastman EGT-10K.3P2M 10 KW 3 Phase Grid Tie Solar Inverter User Manual
Model: EGT-10K.3P2M
1. Introduction
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Eastman EGT-10K.3P2M 10 KW 3 Phase Grid Tie Solar Inverter. Please read this manual thoroughly before installation and operation to ensure proper usage and to prevent potential hazards.

Image 1: Front view of the Eastman EGT-10K.3P2M 10 KW 3 Phase Grid Tie Solar Inverter. The inverter is white with a black display panel showing power output and status. The Eastman logo is prominently displayed.
2. Safety Instructions
Always observe the following safety precautions to reduce the risk of electric shock, fire, or injury to persons:
- Installation and maintenance must be performed by qualified personnel only.
- Do not attempt to repair the inverter yourself. Refer all servicing to qualified service personnel.
- Ensure the inverter is disconnected from all power sources (DC and AC) before performing any maintenance or service.
- The inverter is designed for outdoor installation with IP65 protection, but avoid direct exposure to extreme weather conditions if possible.
- Keep flammable materials away from the inverter.
3. Product Overview
The Eastman EGT-10K.3P2M is a 10 KW 3 Phase Grid Tie Solar Inverter designed for efficient conversion of solar energy into usable AC power for grid integration. Key features include:
- Low startup DC voltage.
- Maximum DC overloading capability of 30%.
- Integrated anti-islanding protection for grid safety.
- Wide AC voltage range for stable operation.
- IP65 protection rating, suitable for outdoor environments.
- BIS certified for quality and safety standards.
- Compatible with TOPCon & Bifacial Panels.

Image 2: An illustration showing the Eastman EGT-10K-3P2M Grid-Tie Inverter (yellow unit) in a solar energy setup, emphasizing its role in minimizing electricity bills and maximizing energy output.

Image 3: A graphic highlighting the smart energy features of the Eastman Grid-Tie Inverter, including Max. Efficiency (97.5%), Low Startup DC Voltage, Max. DC Overloading 30%, and Wide AC Voltage Range. It also notes compatibility with TOPCon & Bifacial Panels.
4. Setup and Installation
The Eastman EGT-10K.3P2M inverter is designed for easy installation. However, due to its electrical nature, installation must be carried out by certified professionals to ensure safety and compliance with local electrical codes.
4.1 Site Selection
- Choose a location that is well-ventilated and protected from direct sunlight to prevent overheating.
- Ensure the mounting surface is strong enough to support the inverter's weight (approximately 10 kg).
- The IP65 rating allows for outdoor installation, providing protection against dust and water jets.
4.2 Electrical Connections
- Connect the DC input from the solar panels to the inverter's DC terminals. Observe correct polarity.
- Connect the AC output of the inverter to the electrical grid. This is a 3-phase inverter, so ensure proper phase connection.
- Ensure all connections are tight and secure to prevent loose contacts and potential hazards.
- Install appropriate overcurrent protection devices on both DC and AC sides.

Image 4: An image illustrating the Eastman Grid-Tie Inverter (yellow unit) in both residential and commercial settings, highlighting its suitability for both. Features like 24/7 App Monitoring, operation at Low Voltage, IP65 Protection, and BIS Certification are shown.
5. Operating Instructions
5.1 Initial Startup
- After all electrical connections are verified, switch on the AC circuit breaker.
- Switch on the DC disconnect switch.
- The inverter will perform a self-test and then begin to operate, converting DC power from solar panels into AC power for the grid.
- Monitor the display panel for operational status and any error messages.
5.2 Remote Monitoring
The Eastman EGT-10K.3P2M supports remote monitoring via the Eastman Solar App. This allows for 24x7 tracking of your inverter's performance and energy generation. Refer to the app's specific instructions for setup and usage.
6. Maintenance
The Eastman EGT-10K.3P2M inverter is designed for low maintenance. Regular checks can help ensure optimal performance and longevity.
- Periodic Visual Inspection: Check for any visible damage, loose connections, or signs of corrosion on the inverter casing and cables.
- Cleaning: Ensure the cooling fins and ventilation openings are free from dust and debris to maintain proper heat dissipation. Use a soft, dry cloth for cleaning. Do not use abrasive cleaners or solvents.
- Performance Monitoring: Regularly check the inverter's performance through the display or the Eastman Solar App to identify any anomalies.
- Professional Inspection: It is recommended to have a qualified technician perform a comprehensive inspection and maintenance check annually.
7. Troubleshooting
This section provides basic troubleshooting steps for common issues. For complex problems or persistent errors, contact Eastman Energy customer support.
| Problem | Possible Cause | Solution |
|---|---|---|
| Inverter not starting/no power output | No DC input from solar panels; AC grid disconnected; Inverter fault. | Check solar panel connections and sunlight availability. Verify AC circuit breaker is on. If problem persists, contact support. |
| Low power output | Insufficient sunlight; Dirty solar panels; Partial shading; Inverter operating below optimal conditions. | Clean solar panels. Check for shading. Monitor weather conditions. If issue continues, consult a technician. |
| Error message on display | Internal fault; Grid issue; Over-voltage/current. | Note down the error code. Refer to the detailed error code list (if available in full manual) or contact customer support with the error code. |
8. Technical Specifications
| Parameter | Value |
|---|---|
| Model Name | Eastman EGT-10K.3P2M, 10 KW |
| Brand | EASTMAN ENERGY |
| Wattage | 10000 Watts (10 KW) |
| Power Source | Solar Powered |
| Item Dimensions (LxWxH) | 47.5 x 33 x 20.3 Centimeters |
| Item Weight | 10 kg |
| Protection Rating | IP65 |
| Certifications | BIS certified |
| Manufacturer | EASTMAN AUTO AND POWER LIMITED |
| Recommended Uses | Home, Office (Residential & Commercial) |
9. Warranty and Support
The Eastman EGT-10K.3P2M Solar Inverter comes with a 10-Year Warranty, ensuring long-term reliability and peace of mind. For warranty claims, technical assistance, or any product-related inquiries, please contact Eastman Energy customer support.
Customer Support Contact:
- Toll-Free Number: 1800 419 8610
- Visit the EASTMAN ENERGY Store for more information.

Image 5: An image depicting a service technician ringing a doorbell, symbolizing Eastman Energy's doorstep service. The customer support number 1800 419 8610 is prominently displayed.
Related Documents - EGT-10K.3P2M
![]() |
STW-Solutions EGT-XMT7100 V1.4 Exhaust Gas Temperature Gauge Installation Manual Comprehensive installation guide for the STW-Solutions EGT-XMT7100 V1.4 digital exhaust gas temperature gauge. Covers setup, sensor compatibility, wiring, basic settings, alarm functions, and temperature guidelines for various vehicle types. |
![]() |
STW EGT-XMT7100 Installation Manual: Exhaust Gas Temperature Gauge Comprehensive installation manual for the STW EGT-XMT7100 Exhaust Gas Temperature Gauge. Learn how to safely install and connect this digital gauge for monitoring vehicle exhaust gas temperatures in cars, motorcycles, and tractors. |
![]() |
Maretron TP-EGT-1 Exhaust Gas Temperature Probe Installation Guide Detailed installation instructions for the Maretron TP-EGT-1 Exhaust Gas Temperature Probe, including wiring, configuration, and connection to the NMEA 2000 network via the TMP100 module. |
![]() |
Koso Dual EGT Gauge (Water Temp + RPM) Instruction Manual Installation and operation manual for the Koso Dual EGT Gauge, featuring water temperature and RPM monitoring, recording functions, and settings configuration. |
![]() |
Exhaust Gas Temperature Meter User Manual (Model GB2214) User manual and safety instructions for the GB2214 Exhaust Gas Temperature Meter, including manufacturer details and usage guidelines. |
![]() |
AMP EFI EGT Controller User Manual - Version 1.03 User manual for the AMP EFI EGT Controller (Version 1.03). Provides detailed instructions for installation, wiring, CAN-Bus configuration, setup, tuning, and troubleshooting for automotive exhaust gas temperature monitoring systems. |
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.