Introduction

This manual provides detailed instructions for the safe and efficient operation of the KORAD KA3005P-23 Programmable Precision Variable Adjustable DC Linear Power Supply. The KA-Series offers a reliable and accurate power source for various applications in labs, colleges, and production environments. Please read this manual thoroughly before using the device.

Unit Features

KORAD KA3005P-23 Unit Features Overview

Image: Overview of the KORAD KA3005P-23 power supply highlighting its key features such as power and protection, memory settings, bright 4-digit LED display, and switchable power input.

  • Reliable & Precise Output: Provides a linear regulated benchtop power supply with precision adjustable voltage and current output (up to 30V/5A).
  • Compact Design: Features an intelligent temperature-controlled fan for cooling and low-noise operation.
  • Fully Programmable: Allows saving and recalling up to four settings (M1-M4). Control options include USB, RS232, RS485, and MODBUS. Coarse/fine controls enable easy adjustment of voltage and current.
  • Multiple Protections: Includes over-voltage protection (OVP), over-current protection (OCP), reverse polarity protection, and short circuit protection to safeguard connected devices and the power supply itself.
  • Bright 4-Digit LED Display: Offers clear and precise readout of voltage and current values.
  • Switchable Power Input: Easily switchable from 110V to 220V via a switch on the rear panel.
  • Keyboard LOCK Function: Prevents accidental changes to settings during operation.

Panel Overview

KORAD KA3005P-23 Front Panel Controls

Image: Detailed view of the KORAD KA3005P-23 front panel, labeling all controls, indicators, and ports.

Front Panel Controls and Indicators:

  • Voltage Display (V): Shows the current output voltage.
  • Current Display (A): Shows the current output amperage.
  • Memory Recall/Save Buttons (M1-M4): Used to store and recall preset voltage and current values.
  • LOCK/UNLOCK Button: Engages or disengages the front panel lock function.
  • BEEP Button: Toggles the keypad beep sound.
  • OVP Button: Toggles Over-Voltage Protection.
  • OCP Button: Toggles Over-Current Protection.
  • OFF/ON Button: Controls the output power.
  • ADJUST Knob: Rotary encoder for adjusting voltage and current values.
  • Digit Selector Buttons (< / >): Selects the digit to adjust with the ADJUST knob.
  • VOLTAGE/CURRENT Button: Toggles between voltage and current adjustment modes.
  • Output Terminals (+, -, GND): Connect your load here.
  • Indicators (OVP, OCP, M1-M4, C.C, C.V, OUT, LOCK): Display various operational statuses and active protections.

Setup

Unpacking and Inspection:

Upon receiving your KORAD KA3005P-23, carefully inspect the packaging for any signs of damage. Open the box and verify that all components are present:

  • KORAD KA3005P-23 Power Supply Unit
  • Instruction Manual (this document)
  • Power Cable
  • Software CD (if applicable)
  • USB Cable

If any items are missing or damaged, contact your supplier immediately.

Placement:

Place the power supply on a stable, level surface with adequate ventilation. Ensure that the fan vents on the rear and sides are not obstructed to allow for proper cooling.

Power Connection:

  1. Ensure the power switch on the rear panel is set to the correct local voltage (110V or 220V).
  2. Connect the provided power cable to the AC inlet on the rear of the unit.
  3. Plug the other end of the power cable into a grounded AC outlet.

Operating Instructions

Basic Operation:

  1. Power On: Press the main power switch on the front panel. The LED display will illuminate.
  2. Set Voltage:
    • Press the VOLTAGE/CURRENT button until the voltage display is active (usually indicated by a flashing digit or cursor).
    • Use the < and > digit selector buttons to choose the digit you wish to adjust.
    • Rotate the ADJUST knob to set the desired voltage.
  3. Set Current Limit:
    • Press the VOLTAGE/CURRENT button until the current display is active.
    • Use the < and > digit selector buttons to choose the digit.
    • Rotate the ADJUST knob to set the desired current limit.
  4. Connect Load: Ensure the output is OFF (OUT indicator is off). Connect your device to the output terminals (+, -, GND).
  5. Enable Output: Press the OFF/ON button to enable the output. The OUT indicator will illuminate, and power will be supplied to your load.

Memory Functions (M1-M4):

The unit allows you to store and recall up to four sets of voltage and current settings.

  1. Saving Settings:
    • Set the desired voltage and current.
    • Press and hold one of the M1-M4 buttons for approximately 3 seconds until a beep sounds, indicating the settings are saved.
  2. Recalling Settings:
    • Briefly press the desired M1-M4 button. The stored voltage and current values will be loaded.

Protection Features:

  • Over-Voltage Protection (OVP): Press the OVP button to enable/disable. When enabled, if the output voltage exceeds a preset limit, the output will shut down to protect the load.
  • Over-Current Protection (OCP): Press the OCP button to enable/disable. When enabled, if the output current exceeds a preset limit, the output will shut down.
  • Keyboard Lock: Press the LOCK/UNLOCK button to prevent accidental changes to settings. The LOCK indicator will light up when active.

Programmable Control

KORAD KA3005P-23 connected to a laptop via USB

Image: The KORAD KA3005P-23 power supply connected to a laptop, demonstrating its programmable control capabilities via USB or RS232 interface.

The KORAD KA3005P-23 can be controlled remotely via a computer using its USB or RS232 interfaces located on the rear panel. This allows for automated testing and precise control of output parameters.

  • Software Installation: Install the provided control software (usually on a CD or available for download from the manufacturer's website) on your computer.
  • Connection: Connect the power supply to your computer using either a USB cable or an RS232 serial cable.
  • Configuration: Refer to the software's user manual for detailed instructions on configuring the communication port and controlling the power supply. The unit supports MODBUS protocol for advanced integration.

Specifications

KORAD KA3005P-23 Unit Specifications Table

Image: A table detailing the technical specifications of the KORAD KA3005P-23 power supply, including voltage range, current range, load regulation, and ripple.

ParameterValue
Voltage Range0-30V
Current Range0-5A
Load Regulation (Voltage)≤0.01% + 2mV
Load Regulation (Current)≤0.1% + 10mA
Line Regulation (Voltage)≤0.01% + 3mV
Line Regulation (Current)≤0.1% + 3mA
Setup Resolution (Voltage)10mV
Setup Resolution (Current)1mA
Setup Accuracy (25°C ± 5°C) (Voltage)≤0.5% + 20mV
Setup Accuracy (25°C ± 5°C) (Current)≤0.5% + 10mA
Ripple (20-20M) (Voltage)≤2mVrms
Ripple (20-20M) (Current)≤2mVrms
Temperature Coefficient (Voltage)≤150ppm
Temperature Coefficient (Current)≤150ppm
Read Back Resolution (Voltage)10mV
Read Back Resolution (Current)1mA
Reaction Time (Voltage Rise)≤100mS
Reaction Time (Voltage Drop)≤100mS
InterfaceProgrammable Interface (USB, RS232)
Weight9.52 Lbs / 4.32 Kg
Dimensions (L x W x H)10.5 x 4.4 x 6.5 inches (260 x 100 x 156 mm)
Output Wattage150 Watts
Cooling MethodAir (Intelligent temperature-controlled fan)
Minimum Input Voltage110 Volts (AC)
KORAD KA3005P-23 Unit Dimensions

Image: Visual representation of the KORAD KA3005P-23 power supply with its dimensions and weight clearly indicated.

Maintenance

  • Cleaning: Disconnect the power supply from the AC outlet before cleaning. Use a soft, dry cloth to wipe the exterior. Do not use abrasive cleaners or solvents.
  • Ventilation: Ensure the ventilation openings are kept clear of dust and debris to maintain proper cooling.
  • Storage: When not in use for extended periods, store the unit in a dry, dust-free environment.

Troubleshooting

ProblemPossible CauseSolution
No power when turned onPower cable not connected; AC outlet fault; Rear panel voltage switch incorrect; Internal fuse blown.Check power cable connection; Test AC outlet; Verify rear panel voltage switch setting; Contact service for fuse replacement.
Output voltage/current cannot be adjustedKeyboard LOCK function active; Incorrect adjustment mode selected.Press LOCK/UNLOCK button; Press VOLTAGE/CURRENT button to select desired adjustment mode.
Output shuts down unexpectedlyOVP or OCP triggered; Short circuit in load.Check OVP/OCP settings and disable if not needed; Inspect load for short circuits; Reduce output settings.
Fan is noisy or runs constantlyUnit is operating under heavy load; Ventilation obstructed.This is normal under heavy load; Ensure clear airflow around the unit.

Warranty and Support

KORAD products are designed for reliability and precision. For warranty information, please refer to the warranty card included with your product or visit the official KORAD website. For technical support, troubleshooting assistance, or service inquiries, please contact your local distributor or KORAD customer service.

Please have your model number (KA3005P-23) and purchase date ready when contacting support.