1. Introduction
Thank you for choosing the Srliya TA881A Induction Electric Pen. This non-contact voltage tester is designed for safe and efficient detection of AC voltage in electrical circuits, helping you identify live and null wires without direct contact. Please read this manual thoroughly before use to ensure proper operation and safety.
Safety Information
- Always assume circuits are live until proven otherwise.
- Do not use the device if it appears damaged or is not functioning correctly.
- This device is intended for non-contact voltage detection only. Do not attempt to use it for direct contact measurements.
- Keep the device away from water and extreme temperatures.
- Replace batteries promptly when the low battery indicator appears to ensure accurate readings.
2. Product Overview
Components and Features
The Srliya TA881A is a compact and user-friendly non-contact voltage tester. It features a digital display, LED indicators, and a built-in flashlight for convenience.

Figure 2.1: Angled view of the Srliya TA881A Induction Electric Pen, highlighting its ergonomic design and control buttons.
- Non-Contact Voltage Detection: Safely detects AC voltage from 12V to 1000V.
- Digital Display: Provides clear visual feedback.
- Sound and Light Alarm: Rapid audible and visual alerts for voltage detection.
- Flashlight Function: Integrated LED light for working in dimly lit environments.
- Automatic Shutdown: Conserves battery life by powering off after 3 minutes of inactivity.
- Low Battery Indicator: Alerts when battery voltage is low.
3. Setup
Battery Installation
The TA881A requires two 1.5V AAA batteries (not included) for operation.
- Unscrew the cap at the top of the pen.
- Insert two 1.5V AAA batteries, ensuring correct polarity (+/-).
- Securely screw the cap back on.

Figure 3.1: Top section of the TA881A, indicating the removable cap for battery access.
4. Operating Instructions
Power On/Off
- To power on, press the red power button. The device will emit a short beep and the display will activate.
- To power off, press and hold the red power button until the device shuts down.
Non-Contact Voltage (NCV) Detection
The TA881A can detect both live (firing) and null (ground) wires.
- Ensure the device is powered on.
- Bring the tip of the electric pen close to the wire or outlet you wish to test.
- Live Wire Detection: If a live wire is detected, the analog bar on the display will show three red segments, accompanied by a rapid sound and light alarm.
- Null/Ground Wire Detection: If a null or ground wire is detected, the analog bar on the display will show three green segments.

Figure 4.1: Front view of the TA881A, illustrating the digital display and control buttons for operation.
Flashlight Function
To activate the built-in flashlight, long-press the blue button. This is useful for illuminating work areas in low-light conditions. Press the blue button again to turn off the flashlight.
Automatic Shutdown
The tester will automatically shut down after approximately 3 minutes of no induction or button activity to conserve battery life.
5. Specifications
| Feature | Specification |
|---|---|
| Model | TA881A |
| Non-Contact Voltage Range | 12-1000V AC, 50/60Hz |
| Working Temperature | 0-40℃ (32-104℉) |
| Storage Temperature | -10-50℃ (14-122℉) |
| Storage Humidity | ≤95% |
| Altitude | ≤2000 meters |
| Power Supply | 2 x 1.5V AAA batteries (not included) |
| Package Dimensions | 6.69 x 1.18 x 1.18 inches |
| Item Weight | 1.8 ounces |
6. Maintenance
Care and Storage
- Clean the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Store the electric pen in a cool, dry place, away from direct sunlight and moisture.
- If the device will not be used for an extended period, remove the batteries to prevent leakage.
Battery Replacement
When the low battery indicator illuminates, replace the batteries as described in the "Battery Installation" section (Section 3.1) to ensure continued accurate performance.
7. Troubleshooting
Common Issues and Solutions
- Device not turning on: Check battery installation and ensure batteries are fresh.
- No detection or inconsistent readings: Ensure the device is powered on and batteries are not low. Make sure the tip is close enough to the conductor.
- Flashlight not working: Check battery level. Ensure the blue button is pressed and held correctly.
8. Warranty and Support
Warranty Information
This product is covered by a standard manufacturer's warranty. Please refer to the product packaging or your point of purchase for specific warranty terms and conditions.
Customer Support