Thank you for purchasing the UWYTGF Tiffany-Style Chandelier. This manual provides essential information for the safe installation, operation, and maintenance of your new ceiling lamp. Please read these instructions thoroughly before installation and retain them for future reference.

Image 1.1: The UWYTGF Tiffany-Style Chandelier featuring three blue stained glass shades, installed in a bedroom setting.
2. Safety Information
WARNING: Risk of electric shock. Disconnect power at the fuse box or circuit breaker before installation or servicing. Improper installation can lead to electric shock or fire.
- Ensure the electrical supply is turned off before beginning installation.
- All electrical connections must be in accordance with local codes, ordinances, or the National Electric Code (NEC).
- Consult a qualified electrician if you are unsure about the installation process.
- Do not exceed the maximum wattage specified for the bulbs.
- Handle stained glass shades with care to prevent breakage.
3. Package Contents
Verify that all components are present and undamaged before proceeding with installation.
- 1 x Chandelier Lamp Body (Iron base with 3 lamp holders)
- 3 x Stained Glass Lampshades
- Mounting Hardware (screws, wire nuts, etc.)
- Instruction Manual
Note: Bulbs are NOT included. Please purchase E27 or E26 base bulbs separately.
4. Specifications
| Feature | Detail |
|---|---|
| Product Name | Tiffany-Style Chandelier |
| Model Number | B0DSMVL4P4 |
| Shade Material | Stained Glass |
| Base Material | Iron |
| Lamp Specifications | 3 Heads (E27 x 3 / E26 x 3) |
| Voltage | 100V-240V (Max 40W per bulb) |
| Overall Diameter | 55 cm (21.6 inches) |
| Overall Height | 17 cm (6.7 inches) |
| Lampshade Diameter | 15 cm (6 inches) |
| Weight | Approx. 4 KG |

Image 4.1: Dimensional diagram of the chandelier, indicating a 55cm diameter, 17cm height, and 15cm lampshade diameter.
5. Setup and Installation
Follow these steps carefully to install your chandelier. It is recommended to have two people for installation.
- Turn off Power: Before starting, ensure the power supply to the installation area is completely turned off at the circuit breaker or fuse box.
- Prepare Mounting: Securely attach the mounting bracket to the ceiling junction box using the provided hardware. Ensure the bracket is firmly fixed and can support the weight of the chandelier.
- Assemble Lamp Heads: Fix each lamp head onto the large disc of the chandelier body. Ensure they are securely fastened.
- Wire Connections: Connect the electrical wires from the chandelier to the corresponding wires from the ceiling. Typically, blue wires connect to blue, and red wires connect to red (or black to black, white to white, and ground to ground). Use wire nuts to secure connections and ensure no bare wires are exposed.
- Mount Chandelier: Carefully lift the chandelier and attach it to the ceiling mounting bracket. Secure it with the provided screws or nuts.
- Install Bulbs: Take out the small circular retaining ring on each lamp holder. Insert the appropriate E27 or E26 base bulbs (not included) into the sockets. Fix the cover (stained glass shade) and secure it with the retaining ring.
- Restore Power: Once installation is complete and all connections are secure, restore power at the circuit breaker.

Image 5.1: Visual guide for chandelier installation, showing steps from fixing lamp heads to wiring and final bulb installation.
6. Operating Instructions
The UWYTGF Tiffany-Style Chandelier operates like a standard ceiling light fixture. Once installed and powered, it can be controlled via a wall switch connected to the circuit.
- Turning On/Off: Use the wall switch to turn the chandelier on or off.
- Bulb Replacement: To replace a bulb, ensure the power is off at the circuit breaker. Carefully remove the stained glass shade by unscrewing its retaining ring. Unscrew the old bulb and screw in a new E27 or E26 bulb of the correct wattage. Reattach the shade and retaining ring.
7. Maintenance
Regular maintenance will help preserve the appearance and functionality of your chandelier.
- Cleaning: Dust the chandelier regularly with a soft, dry cloth. For stained glass shades, gently wipe with a damp cloth and mild soap if necessary, then dry immediately. Avoid abrasive cleaners or harsh chemicals, as these can damage the finish or glass.
- Inspection: Periodically check all connections and mounting hardware to ensure they remain secure.
8. Troubleshooting
If you encounter issues with your chandelier, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Light does not turn on | 1. Power supply is off 2. Loose wire connection 3. Faulty bulb | 1. Check circuit breaker/wall switch 2. Turn off power and check wiring connections 3. Replace bulb |
| Flickering light | 1. Loose bulb 2. Incorrect bulb type/wattage 3. Loose wiring | 1. Tighten bulb 2. Ensure correct bulb type and wattage 3. Turn off power and check wiring connections |
| Chandelier is unstable | Loose mounting hardware | Turn off power and tighten all mounting screws/nuts. |
If the problem persists after attempting these solutions, please contact customer support.