1. Introduction

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Reznor UDXC-60 Natural Gas Unit Heater. The UDXC-60 is a 60,000 BTU unit designed for indoor use in various commercial, industrial, or residential spaces such as garages, workshops, and warehouses.

Reznor UDXC-60 Natural Gas Unit Heater

Image 1.1: Front view of the Reznor UDXC-60 Natural Gas Unit Heater.

Please read this manual thoroughly before attempting to install, operate, or service the unit. Retain this manual for future reference.

2. Safety Information

WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Read the installation, operating, and maintenance instructions thoroughly before installing or servicing this equipment.

  • This appliance must be installed by a qualified installer or service agency.
  • Ensure adequate ventilation is provided for combustion air and proper exhaust of flue gases.
  • Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Carbon Monoxide (CO) poisoning can occur if the heater is not properly installed and vented. Install carbon monoxide detectors in the area where the heater is located.
  • Always turn off the gas supply and electrical power to the unit before performing any service or maintenance.

3. Product Features

The Reznor UDXC-60 unit heater is engineered for reliable and efficient heating, incorporating several advanced features:

  • High Performance: Rated for 60,000 BTU with an 83% thermal efficiency rating.
  • Durable Construction: Features a TCORE2 titanium-stabilized aluminized steel heat exchanger for extended lifespan.
  • Advanced Combustion: Patented single-burner combustion system.
  • Integrated Controls: Equipped with an integrated circuit board, a 7-segment display for diagnostics, a built-in disconnect switch, and a status-indicating LED.
  • Quiet Operation: Designed with a low static propeller fan and vibration-isolated fan and venter motors for reduced noise.
  • Mounting Versatility: Threaded-nut retainers at four suspension points allow for ceiling or wall mounting (mounting hardware sold separately).
  • External Connections: External gas connection and external terminal strip for 24V wiring simplify installation and maintenance.
  • ETL Approved: Certified for safety and performance.
Reznor UDXC-60 Unit Heater Standard Features

Image 3.1: Overview of standard features including efficiency, heat exchanger, and quiet operation.

Reznor UDXC-60 Unit Heater Additional Standard Features

Image 3.2: Additional features such as status LED, display board, suspension options, and external gas connection.

4. Setup and Installation

Installation of this natural gas unit heater must be performed by a qualified professional in accordance with all local codes and ordinances, as well as national standards such as NFPA 54 (National Fuel Gas Code) and NFPA 70 (National Electrical Code).

4.1 Mounting

The UDXC-60 is designed for ceiling or wall mounting. It features threaded-nut retainers at four suspension points. Appropriate mounting brackets and hardware must be purchased separately and selected based on the installation location and structural requirements.

Reznor UDXC-60 Unit Heater installed in a garage

Image 4.1: Example of a Reznor unit heater installed in a workshop environment.

4.2 Venting

The unit includes a vertical Category 1 double wall B-vent kit for venting exhaust gases out of a roof. Ensure the vent system is installed correctly to prevent flue gas spillage and ensure proper combustion.

  • The included kit typically contains: 1x Reznor CCI Vent Cap, 1x Draft Hood Connector, 2x 12" Length Straight Pipe, 2x 24" Length Straight Pipe, 2x 60° Adjustable Elbow, 1x 90° Adjustable Elbow, 1x Roof Flashing (up to 5/12 Pitch), and 1x 4" Diameter Storm Collar.
  • Refer to the detailed instructions provided with the vent kit for proper assembly and installation.
Vertical Category I Vent Kit Components

Image 4.2: Components of the vertical Category I B-vent kit.

4.3 Gas and Electrical Connections

Connect the natural gas supply to the external gas connection point on the unit. All gas piping must comply with local codes and be leak-tested after installation. The unit requires a 24V electrical supply, connected via the external terminal strip. Ensure all wiring is correctly sized and protected.

Simplified Installation and Advanced Features Diagram

Image 4.3: Diagram illustrating simplified installation features including external connections and internal components.

5. Operating Instructions

Once properly installed and connected, the Reznor UDXC-60 heater is designed for straightforward operation.

5.1 Initial Startup

  1. Ensure the gas supply valve to the unit is open.
  2. Turn on the electrical power to the unit.
  3. Set the thermostat to the desired temperature. The unit will initiate its ignition sequence.

5.2 Heating Flexibility

The single-burner design offers two BTU outputs, allowing for efficient heating across various temperature conditions. The unit automatically adjusts to provide high fire for colder days and low fire for milder temperatures.

5.3 Air Circulation

The low static pressure axial fan and power venting system ensure effective air circulation and minimize heat loss, distributing warmth evenly throughout the space.

6. Maintenance

Regular maintenance is crucial for the longevity and efficient operation of your Reznor UDXC-60 heater. All maintenance should be performed by a qualified service technician.

  • Annual Inspection: Have the unit inspected annually by a qualified technician. This includes checking the heat exchanger, burner, ignition system, and venting.
  • Cleaning: Keep the area around the heater clear of obstructions. Periodically clean the exterior of the unit and ensure the fan blades are free of dust and debris.
  • Filter Replacement: If your installation includes an air filter, inspect and replace it regularly as per manufacturer recommendations.

7. Troubleshooting

The UDXC-60 features a 7-segment display board and a status-indicating LED to assist with troubleshooting. Refer to the unit's diagnostic codes for specific issues.

  • No Heat: Check if the thermostat is set correctly, if the gas supply is open, and if electrical power is supplied to the unit. Consult the LED and display for error codes.
  • Unusual Noises: Ensure the unit is securely mounted and free from obstructions. If noises persist, contact a service technician.
  • Pilot Light Out (if applicable): Follow the relighting instructions on the unit or in the full manufacturer's manual.

For complex issues or if you are unsure about a problem, contact a qualified HVAC service technician.

8. Specifications

Key technical specifications for the Reznor UDXC-60 Natural Gas Unit Heater:

SpecificationDetail
Brand1HVAC (Reznor)
Model NumberUDXC-60
BTU Rating60,000 BTU
Thermal Efficiency83%
Fuel TypeNatural Gas
Indoor/Outdoor UsageIndoor
Form FactorCeiling Mount
Product Dimensions (D x W x H)32.72" x 27" x 16.75"
Heat Exchanger MaterialTCORE2 Titanium-Stabilized Aluminized Steel
Fan TypeLow Static Propeller Fan
Number of Speeds2
Venting IncludedVertical Category 1 B-Vent Kit
CertificationsETL Approved
Reznor UDXC-60 Unit Heater Dimensions

Image 8.1: Dimensional overview of the Reznor UDXC-60 unit heater.

9. Warranty and Support

For detailed warranty information, please refer to the official warranty statement provided by Reznor or 1HVAC at the time of purchase. Warranty terms typically cover defects in materials and workmanship for a specified period.

For technical support, service, or to inquire about replacement parts, please contact the manufacturer or your authorized dealer. Ensure you have your model number (UDXC-60) and serial number available when contacting support.

Related Documents - UDXC-60

Preview 1HVAC Inverter Heat Pump for Swimming Pools: User Manual
Comprehensive user manual for 1HVAC Inverter Heat Pumps (PHP-50, PHP-65, PHP-90, PHP-110, PHP-140) for swimming pools, covering installation, operation, maintenance, troubleshooting, and warranty.
Preview Reznor Gas Conversion Kit Installation for Gas-Fired Unit Heaters
This document provides installation instructions for Reznor gas conversion kits for various gas-fired unit heater models, including UBX, UBXC, UBZ, UDX, UDXC, UDZ, UDAP, UDAS, UDBP, and UDBS. It details component selection, safety precautions, and installation steps for converting between natural gas and propane, as well as for high-elevation installations.
Preview Reznor Ceiling Suspension Kit Installation Guide for Electric and Gas-Fired Unit Heaters
Installation instructions and component details for the Reznor CK22 Ceiling Suspension Kit, compatible with EHU electric and UDXC, UDX, UDZ gas-fired unit heaters. Learn how to safely mount your Reznor heater.
Preview Reznor Relay Kit Installation Guide for Multiple Unit Control (CL31/CL32)
Comprehensive installation guide for Reznor CL31 and CL32 relay kits, enabling multiple unit control for various Reznor electric and gas-fired heaters. Includes component lists, detailed installation steps, and wiring specifications.
Preview Reznor Vertical Louver Kit Installation Guide for Gas-Fired Unit Heaters (OPT-CD1)
Installation instructions for the Reznor OPT-CD1 Vertical Louver Kit, designed for gas-fired unit heaters (models UBX, UBXC, UBZ, UDX, UDXC, UDZ, UEZ). Includes component list and step-by-step assembly guide.
Preview Reznor UBXC/UDXC Gas-Fired Unit Heater Replacement Parts Manual
This manual provides detailed replacement parts information for Reznor UBXC and UDXC series gas-fired unit heaters. It includes sections on serial number decoding, electrical components, fan and motor assemblies, blower assemblies, cabinet components, heat exchanger and burner assemblies, venter and flue wrapper components, and various accessories and options.