1. Introduction
This manual provides essential instructions for the safe installation, operation, and maintenance of your LEDVANCE Dual Selectable Flood LED Light. This versatile floodlight is designed for outdoor illumination of buildings, facades, signs, gardens, and other areas. It features selectable lumen packages (80W, 100W, 140W), selectable color temperatures (3000K, 4000K, 5000K), and an integrated photocell for enhanced functionality.
Please read this manual thoroughly before installation and retain it for future reference.

Figure 1: Front view of the LEDVANCE Dual Selectable Flood LED Light.
2. Safety Information
WARNING: Risk of electric shock. Disconnect power before installation or servicing. Installation should be performed by a qualified electrician in accordance with all national and local electrical codes.
- Ensure the supply voltage is 120V AC.
- Do not install near combustible materials.
- The luminaire is rated IP65 for wet locations, ensuring protection against dust and water jets.
- Do not modify the fixture. Any modifications may void the warranty and create safety hazards.
- Ensure all connections are secure and properly insulated.
3. Package Contents
Verify that all components are present before beginning installation:
- LEDVANCE Dual Selectable Flood LED Light (1 unit)
- Mounting Hardware (includes components for knuckle and trunnion mounting)
- Shorting Cap (pre-installed on NEMA 3-pin receptacle)
4. Installation
The LEDVANCE Flood LED Light offers flexible mounting options, including knuckle mount and trunnion mount, suitable for wall or pole applications. Always ensure the mounting surface can support the weight of the fixture.
4.1 Mounting Options
The fixture comes with hardware for two primary mounting methods:
- Knuckle Mount: Allows for adjustable angle positioning, typically used for direct wall or junction box mounting.
- Trunnion Mount: A U-shaped bracket for surface mounting, offering robust support and angle adjustment.

Figure 2: Example of the floodlight with a knuckle mount.
4.2 Wiring
- Ensure power to the circuit is turned OFF at the breaker before proceeding.
- Connect the fixture's wires to the main power supply:
- Black wire to Line (L)
- White wire to Neutral (N)
- Green/Ground wire to Ground (G)
- Secure all wire connections with appropriate wire nuts or connectors.
- Ensure the NEMA 3-pin receptacle, if used, has the shorting cap securely in place for standard operation without external controls.
4.3 Dimensions

Figure 3: Product dimensions for installation planning.
5. Operation
The LEDVANCE Dual Selectable Flood LED Light features adjustable power output and color temperature settings to suit various lighting needs.
5.1 Power and Color Temperature Selection
The fixture includes internal switches (often DIP switches located under protective covers on the top or side of the unit) for selecting the desired wattage and color temperature. These settings must be configured before applying power to the fixture.
- Wattage Selection: Choose between 80W, 100W, or 140W to adjust the lumen output. Refer to the labels near the switch for specific settings.
- Color Temperature (CCT) Selection: Select 3000K (Warm White), 4000K (Neutral White), or 5000K (Daylight White). Refer to the labels near the switch for specific settings.
After adjusting the switches, ensure the protective covers are securely re-sealed to maintain the IP65 rating.
5.2 Dimmable Functionality
This floodlight supports 0-10V dimming. To utilize the dimming feature, connect the fixture to a compatible 0-10V dimmer switch. Consult a qualified electrician for proper wiring of dimming controls.
5.3 Photocell Function
The integrated photocell automatically turns the light on at dusk and off at dawn, providing energy-efficient operation. Ensure the photocell sensor is not obstructed by objects or direct light sources (e.g., other lights) to prevent erratic behavior.

Figure 4: Example of the floodlight in an outdoor application.
6. Maintenance
Regular maintenance ensures optimal performance and longevity of your LEDVANCE floodlight.
- Cleaning: Periodically clean the exterior of the fixture with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure power is disconnected before cleaning.
- Inspection: Annually inspect the fixture for any signs of damage, loose wiring, or corrosion. Address any issues promptly.
- Photocell: Keep the photocell sensor clean and free from obstructions to ensure proper automatic operation.
7. Troubleshooting
If you experience issues with your LEDVANCE floodlight, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Light does not turn on. | No power supply. Faulty wiring. Photocell active (daylight). | Check circuit breaker. Verify wiring connections. Test at night or cover photocell. |
| Light flickers or dims unexpectedly. | Loose wiring connection. Incompatible dimmer switch. Power fluctuations. | Inspect and secure all wiring. Ensure a compatible 0-10V dimmer is used. Consult an electrician for power supply issues. |
| Incorrect color temperature or brightness. | Switches not set correctly. | Disconnect power, open protective cover, and verify wattage/CCT switch settings. |
| Photocell not functioning correctly. | Sensor obstructed. Sensor receiving ambient light. | Clear any obstructions from the sensor. Relocate fixture or shield sensor from other light sources. |
If issues persist after attempting these solutions, contact customer support.
8. Specifications
| Feature | Detail |
|---|---|
| Model Number | 63862 |
| Wattage | Selectable: 80W / 100W / 140W |
| Lumen Output | Up to 21000 Lumens (at 140W) |
| Color Temperature (CCT) | Selectable: 3000K / 4000K / 5000K |
| Voltage | 120 Volts AC |
| Dimmable | Yes, 0-10V Dimming |
| Photocell | Integrated |
| Material | Metal |
| Dimensions (L x W x H) | 10.95" x 2.28" x 8.82" |
| Weight | Approximately 7.06 lbs |
| IP Rating | IP65 (Wet Rated) |
| Certifications | cULus listed to UL1598, RoHS, FCC |
| Rated Life | 100,000 hours |
| CRI | 80 |
| Surge Protection | 6kV |
9. Warranty
The LEDVANCE Dual Selectable Flood LED Light (Model 63862) is backed by a 5-year manufacturer's warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use and service. Please retain your proof of purchase for warranty claims. For full warranty terms and conditions, please refer to the official LEDVANCE website or contact customer support.
10. Customer Support
For technical assistance, warranty inquiries, or further information regarding your LEDVANCE product, please visit the official LEDVANCE website or contact their customer service department. Contact details can typically be found on the product packaging or the manufacturer's website.
Online Resources: Visit the LEDVANCE Store on Amazon