1. Introduction
The Daytech DA10 Refrigerator & Freezer Door Alarm is designed to alert users when a refrigerator or freezer door has been left open for an extended period. This device helps prevent food spoilage and unnecessary energy consumption. It features adjustable delay settings, multiple volume levels, and two distinct alert modes (chime or alarm) to suit various environments, including homes, supermarkets, and businesses.

Image: Three Daytech DA10 Refrigerator and Freezer Door Alarms.
2. Package Contents
The package includes the following items:
- Daytech DA10 Refrigerator & Freezer Door Alarm Main Unit(s)
- Magnetic Strip(s)
- User Manual
- AAA Batteries (2 per alarm unit)
- Mounting Screws (optional for installation)
- Double-sided Adhesive Tape (pre-applied or separate)
Video: Product Unboxing. This video demonstrates the contents of the product package, including the main alarm unit, magnetic strip, user manual, batteries, and mounting accessories.
3. Product Overview
The Daytech DA10 alarm consists of a main unit and a smaller magnetic strip. The main unit houses the buzzer, LED indicator, and control switches for mode selection, volume adjustment, and power.

Image: Detailed view of the Daytech DA10 alarm unit, highlighting its components and dimensions.
Key Features:
- Delayed Alert: Adjustable delay times of 1, 2, 3, or 4 minutes before the alarm sounds.
- Volume Control: 5 levels of volume adjustment, from 0 dB (silent) to 120 dB.
- Ringtone Modes: Two distinct modes: CHIME (a gentle alert) and ALARM (a loud siren).
- Low Battery Warning: The alarm will beep for a shorter period when batteries are low, indicating replacement is needed.
- Automatic Shut-off: Alarm stops after 30 minutes of continuous activation if the door remains open.
4. Setup & Installation
Follow these steps to install your Daytech DA10 door alarm:
- Prepare the Surface: Ensure the surface where the alarm will be mounted is clean and dry.
- Attach Adhesive Tape: Apply the provided double-sided adhesive tape to the back of both the main unit and the magnetic strip.
- Position the Units: Carefully peel off the backing from the tape. Mount the main unit and the magnetic strip on the door and its frame (or two adjacent doors) so that the triangle marks on both units are aligned when the door is closed.
- Ensure Proper Gap: The distance between the main unit and the magnetic strip must be ≤ 0.98 inches (2.5 cm) when the door is closed for proper operation.

Image: Step-by-step guide for easy installation using adhesive tape and ensuring proper alignment.
Recommended Installation Locations:

Image: Examples of various suitable installation locations for the alarm, including refrigerators, freezers, windows, and cabinets.
5. Operating Instructions
5.1. Selecting Ringtone Mode (CHIME/ALARM)
Use the 'CHIME/ALARM/OFF' switch on the side of the main unit to select your preferred alert sound. Slide the switch to 'CHIME' for a gentle notification or 'ALARM' for a louder, more urgent sound. The 'OFF' position disables the alarm.
5.2. Adjusting Volume
The alarm offers 5 adjustable volume levels, ranging from 0 dB (silent) to 120 dB. Use the volume buttons (+/-) on the side of the main unit to increase or decrease the sound level.
Video: Daytech Freezer Door Alarm with Delay Function Introduction. This video demonstrates how to switch between chime and alarm modes, and adjust the volume levels of the device.
5.3. Setting Delay Time (Work Mode)
The alarm features four delay modes, allowing you to choose how long the door can remain open before an alert is triggered:
- Mode 1 (1 Minute Delay): Alert after 60 seconds. Beeps every 15 seconds for 5 seconds until the door closes. Ideal for refrigerators or basement doors.
- Mode 2 (2 Minute Delay): Alert after 2 minutes. Beeps every 10 seconds for 10 seconds until the door closes. Suitable for garages or shed doors.
- Mode 3 (3 Minute Delay): Alert after 3 minutes. Beeps every 5 seconds for 15 seconds until the door closes. Useful for windows or cabinet doors.
- Mode 4 (4 Minute Delay): Alert after 4 minutes. Beeps every 20 seconds for 15 seconds until the door closes. Applicable for office or shop doors.
To change the delay mode, press the 'Work Mode Set Key' on the side of the main unit. The number of beeps will confirm the selected mode (e.g., one beep for Mode 1, two beeps for Mode 2, etc.).

Image: Overview of the four adjustable delay modes and their respective alert patterns.
Video: Daytech Freezer Door Alarm with Delay 1/2/3/4 mins Reminder. This video demonstrates the different delay settings and how the alarm functions after the set delay.
5.4. Loud Alarm Example

Image: Example of the 120 dB loud alarm function, suitable for environments where a strong alert is needed.
6. Maintenance
6.1. Battery Replacement
When the alarm unit emits shorter beeps, it indicates that the batteries are running low and need to be replaced. The unit requires 2 AAA batteries.
- Gently slide the battery cover downwards to open the battery compartment.
- Remove the old AAA batteries.
- Insert two new AAA batteries, ensuring correct polarity (+/-).
- Slide the battery cover back into place until it clicks securely.
Video: Daytech Freezer Door Alarm Display. This video demonstrates the battery replacement process for the alarm unit.
7. Troubleshooting
- Alarm not sounding:
- Check if the 'CHIME/ALARM/OFF' switch is in the 'OFF' position.
- Ensure batteries are correctly installed and not depleted. Replace if necessary.
- Verify that the main unit and magnetic strip are aligned and within the ≤ 0.98 inch (2.5 cm) distance when the door is closed.
- Alarm sounds too frequently:
- Adjust the delay time using the 'Work Mode Set Key' to a longer duration (e.g., 2, 3, or 4 minutes).
- Ensure the door is fully closed and the units are properly aligned.
- Alarm is too quiet/loud:
- Adjust the volume using the +/- buttons on the side of the main unit.
8. Specifications
| Feature | Specification |
|---|---|
| Model Number | DA10 |
| Voltage | 3 Volts (DC) |
| Mounting Type | Door Mount (Adhesive/Screws) |
| Maximum Range (Sensor Gap) | 0.98 Inches (2.5 cm) |
| Sensor Technology | Contact Sensor |
| Item Weight | 8.8 ounces |
| Product Dimensions | 2.52 x 1.34 x 4.57 inches |
| Batteries Required | 2 AAA batteries (included) |
| Battery Cell Type | Alkaline |
| Color | Grey |
9. Warranty & Support
For warranty information and customer support, please refer to the contact details provided in your product packaging or visit the official Daytech website. Keep your purchase receipt for warranty claims.