Atosa MCF8705GRL

Atosa Commercial Stainless Steel Glass Door Refrigerator Merchandiser

Model: MCF8705GRL (19.1 cu. ft., Left Hinge) - Instruction Manual

1. Introduction

Thank you for choosing the Atosa Commercial Stainless Steel Glass Door Refrigerator Merchandiser. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your new unit. Please read these instructions thoroughly before using the appliance and retain them for future reference.

This unit is designed for commercial use to store and display refrigerated products within a temperature range of 33°F to 38°F (0.5°C to 3.3°C).

2. Safety Information

WARNING: Risk of electric shock. Disconnect power before servicing.

  • Ensure the unit is properly grounded.
  • Do not operate the unit with a damaged power cord or plug.
  • Do not use extension cords with this appliance.
  • Keep ventilation openings clear of obstructions.
  • Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Children should be supervised to ensure that they do not play with the appliance.
  • The unit uses R290 Hydrocarbon refrigerant. Servicing should only be performed by authorized personnel.

3. Unpacking and Setup

3.1 Unpacking

Carefully remove all packaging materials, including tape and protective film. Inspect the unit for any shipping damage. Report any damage immediately to the carrier and your supplier.

3.2 Placement

Place the refrigerator on a strong, level surface capable of supporting its weight (approximately 326 lbs empty, plus contents). Ensure adequate air circulation around the unit. Maintain a minimum of 6 inches (15 cm) clearance from walls or other obstructions for proper ventilation of the condenser coil.

Avoid placing the unit in direct sunlight, near heat-producing equipment, or in areas with high humidity.

3.3 Caster Installation

The unit is equipped with 4-inch casters for mobility. Ensure all casters are securely locked once the unit is in its final position to prevent accidental movement.

3.4 Initial Cleaning

Before first use, clean the interior and exterior surfaces with a mild soap and water solution. Rinse thoroughly and dry completely.

3.5 Power Connection

Connect the unit to a dedicated 115V/60Hz/1-ph electrical outlet with a NEMA 5-15P plug. The unit draws 2.1 amps. Do not overload the circuit.

3.6 Initial Startup

After placement and power connection, allow the unit to sit for at least 2 hours before turning it on. This allows the refrigerant to settle. Turn on the unit using the main power switch. The digital temperature controller will display the current internal temperature.

Atosa Commercial Refrigerator with door open, showing interior shelves and products

Image: Front view of the Atosa Commercial Stainless Steel Glass Door Refrigerator Merchandiser with the left-hinged door open, revealing four adjustable shelves stocked with various beverages. The LED interior lighting is visible.

4. Operating Instructions

4.1 Digital Temperature Control

The unit features a digital temperature controller to maintain temperatures between 33°F and 38°F. Refer to the controller's specific instructions for detailed programming. Generally, press the 'SET' button to view the set temperature, and use the up/down arrows to adjust it. Press 'SET' again to confirm.

Close-up of the digital temperature controller and power switch on the Atosa refrigerator

Image: Close-up of the control panel located at the top right of the refrigerator, showing the digital temperature display (Dixell brand) and the main power switch.

4.2 Adjustable Shelves

The refrigerator includes four adjustable shelves. To adjust, lift the shelf slightly, remove the shelf clips from the support rails, reposition the clips to the desired height, and then place the shelf back onto the clips. Ensure shelves are level and securely seated before loading products.

4.3 LED Interior Lighting

The unit is equipped with bright LED interior lighting for enhanced product visibility. The lighting typically operates automatically when the door is opened or can be controlled via a dedicated switch, if present.

4.4 Door Lock

The self-closing hinged glass door includes a lock for security. Use the provided key to lock or unlock the door as needed.

5. Maintenance

WARNING: Always disconnect power to the unit before performing any maintenance or cleaning.

5.1 Cleaning the Interior

Regularly clean the interior with a mild, non-abrasive cleaner and warm water. Avoid harsh chemicals or abrasive pads that can damage surfaces. Rinse with clean water and dry thoroughly to prevent odors and bacterial growth.

5.2 Cleaning the Exterior

Wipe down the stainless steel exterior with a soft cloth and a stainless steel cleaner or mild soap and water. Polish in the direction of the grain to avoid scratches. Do not use abrasive cleaners.

5.3 Condenser Coil Cleaning

The condenser coil, located at the bottom of the unit, should be cleaned every 30 days or as needed to ensure efficient operation. Use a stiff brush or vacuum cleaner to remove dust and debris from the coil fins. A dirty condenser coil can lead to increased energy consumption and reduced cooling performance.

5.4 Automatic Air Defrost

This unit features an automatic air defrost system, eliminating the need for manual defrosting under normal operating conditions. If excessive ice buildup occurs, check door seals and ensure proper ventilation.

5.5 Door Gasket Inspection

Regularly inspect the door gasket for cracks, tears, or signs of wear. A damaged gasket can lead to air leaks, affecting cooling efficiency. Replace damaged gaskets promptly.

6. Troubleshooting

ProblemPossible CauseSolution
Unit not coolingPower supply issue
Thermostat set too high
Dirty condenser coil
Door left open or gasket leak
Check power connection and circuit breaker
Adjust thermostat to a lower setting
Clean condenser coil
Ensure door is closed and gasket is sealing properly
Excessive noiseUnit not level
Loose components
Fan obstruction
Level the unit using the casters
Inspect for loose screws or parts
Check for obstructions around fan blades
Water on floor (leak)Clogged drain line
Excessive humidity
Clear the drain line
Ensure door is closed properly; reduce ambient humidity if possible
Door not closing properlyDamaged or dirty gasket
Unit not level
Hinge issue
Clean or replace gasket
Level the unit
Contact service for hinge repair

If troubleshooting steps do not resolve the issue, please contact qualified service personnel.

7. Specifications

FeatureDetail
BrandAtosa
Model NumberMCF8705GRL
Capacity19.1 Cubic Feet
Product Dimensions (D x W x H)31.7" x 27" x 83.1"
Item Weight326 pounds
Installation TypeFreestanding
Number of Doors1 (Left Hinge)
Temperature Range33°F to 38°F (0.5°C to 3.3°C)
RefrigerantR290 Hydrocarbon
Compressor1/7 HP
Electrical Requirements115V/60/1-ph, 2.1 Amps
Plug TypeNEMA 5-15P
Defrost SystemAutomatic Air Defrost
Interior LightingLED
Special FeaturesLockable Door, 4" Casters, Stainless Steel Interior/Exterior

8. Warranty and Support

For warranty information and technical support, please refer to the warranty card included with your product or contact Atosa customer service directly. You may also reach out to your point of purchase for assistance.

Ask a question about this manual