ORIA B0DS8GYTCJ

ORIA Digital Infrared Thermometer User Manual

Model: B0DS8GYTCJ

1. Introduction

Thank you for choosing the ORIA Digital Infrared Thermometer. This non-contact temperature gun is designed for fast, accurate, and convenient surface temperature measurements across a wide range of applications, including cooking, automotive repair, and industrial use. It features a wide measurement range, fast response time, adjustable emissivity, and a backlit LCD display for ease of use.

Important Note: This device is NOT designed for measuring human body temperature. It measures surface temperature only.

2. Safety Information

3. Package Contents

Please check the package contents upon opening to ensure all items are present and undamaged:

ORIA Digital Infrared Thermometer, 2 AAA batteries, and user manual laid out on a white surface.

Image: Contents of the ORIA Digital Infrared Thermometer package, including the thermometer, two AAA batteries, and the user manual.

4. Product Specifications

SpecificationValue
Measurement Range-58℉~1022℉ (-50℃~550℃)
Accuracy±3℉ (±1.5℃) from 14 to 302℉ (-10 to 150℃), otherwise ±1.5%
Resolution±1%/±1℃
Wavelength5um-14um
Distance-Spot Ratio12:1
Response Time500ms
Emissivity0.10-1.00 (Default 0.95)
BacklightAuto-off after 15 seconds
Auto-offAuto-off after 30 seconds of inactivity
Battery2x AAA batteries, 3.0V (included)
MaterialAcrylonitrile Butadiene Styrene
Display TypeLCD

5. Setup

5.1 Battery Installation

The ORIA Digital Infrared Thermometer requires 2 AAA batteries (included). Follow these steps to install them:

  1. Locate the battery cover on the handle of the thermometer.
  2. Slide or open the battery cover as indicated by the arrow or latch.
  3. Insert the 2 AAA batteries, ensuring the correct polarity (+ and -) as marked inside the compartment.
  4. Close the battery cover securely until it clicks into place.
Diagram showing the battery cover location and how to open it on the ORIA Digital Infrared Thermometer.

Image: A detailed view of the ORIA Digital Infrared Thermometer, highlighting the battery cover and its opening mechanism.

The thermometer is now ready for use. If the low battery indicator appears on the display, replace the batteries promptly.

6. Operating Instructions

6.1 Basic Operation

To take a temperature reading:

  1. Point the thermometer at the target surface. Ensure the distance-to-spot ratio (12:1) is considered for accurate readings.
  2. Pull and hold the trigger. The laser pointer will activate (if enabled) to help aim, and the display will show the current temperature.
  3. Release the trigger to hold the reading on the display. The device will automatically shut off after 30 seconds of inactivity to conserve battery.
Hand holding the ORIA Digital Infrared Thermometer, pointing it at food on a grill, with the display showing a temperature reading.

Image: Demonstrates the ease of use, showing a user simply pulling the trigger to take a temperature reading of grilled food.

6.2 Display and Buttons

The LCD screen provides clear readings and indicators:

Close-up of the ORIA Digital Infrared Thermometer's LCD display showing various indicators like SCAN, HOLD, temperature values, emissivity, MAX, MIN, AVG, infrared status, and low battery icon.

Image: Detailed view of the LCD display and control buttons, explaining icons for HOLD, SCAN, Temperature values, Infrared on, Low Battery Icon, °C/°F Switch, Emissivity (EMI), MAX, MIN, and AVG.

6.3 Adjustable Emissivity

Emissivity is the ability of a material to emit energy. Different materials have different emissivity values. This thermometer allows you to adjust the emissivity from 0.10 to 1.00 (default 0.95) for more accurate readings on various surfaces.

  1. While the device is on, press the 'MODE' button until 'EMI' appears on the display.
  2. Use the up/down arrow buttons to adjust the emissivity value.
  3. Refer to common emissivity tables for specific materials to achieve optimal accuracy.
ORIA Digital Infrared Thermometer showing adjustable emissivity setting, with examples of different materials like oil, water, and iron and their typical emissivity values.

Image: Illustrates the adjustable emissivity feature, showing how to set the value and providing examples of common materials (oil, water, iron) with their corresponding emissivity for increased accuracy.

6.4 Product Demonstration Video

Video: A short product show demonstrating the ORIA Digital Infrared Thermometer's features and appearance.

7. Maintenance

8. Troubleshooting

ProblemPossible CauseSolution
Device does not turn on.Dead or incorrectly installed batteries.Check battery polarity or replace with new AAA batteries.
Inaccurate readings.Incorrect emissivity setting; target too far; lens dirty; device not designed for human temperature.Adjust emissivity for the material; ensure proper distance; clean the lens; remember it's not for human use.
Laser not visible.Laser function is turned off.Press the laser button to turn it on.
Display is dim or flickering.Low battery.Replace batteries.

9. Warranty and Support

For warranty information and customer support, please refer to the documentation included with your purchase or contact ORIA customer service directly. Keep your purchase receipt for warranty claims.

Online Support: You may also visit the official ORIA store on Amazon for product information and support: ORIA Store

Related Documents - B0DS8GYTCJ

Preview EAE KNX Oria Switch Series Installation Manual
Installation guide for the EAE KNX Oria Switch Series, detailing operation, installation, technical specifications, and commissioning for smart home automation systems.
Preview Audient ORIA mini Room Correction System Manual
The official manual for the Audient ORIA mini Room Correction System. Learn how to install, set up, and use this hardware solution, developed with Sonarworks, to achieve accurate studio monitoring and optimize your room acoustics.
Preview Audient ORIA mini Room Correction System Manual V1
User manual for the Audient ORIA mini room correction system, covering introduction, installation, setup, hardware features, software functions, troubleshooting, technical specifications, warranty, and Sonarworks integration. Learn how to optimize your studio monitoring environment with this powerful tool.
Preview Audient ORIA イマーシブオーディオインターフェイス & モニターコントローラー マニュアル V1.2
Audient ORIA イマーシブオーディオインターフェイス & モニターコントローラーのセットアップ、ハードウェア・ソフトウェア機能、接続性、キャリブレーション、仕様に関する詳細情報を提供する公式マニュアルです。プロフェッショナルなオーディオ制作環境を最適化します。
Preview Defender Wired Gaming Mouse Operation Manual - Model Guide
Comprehensive operation manual for Defender wired gaming mice, including safety instructions, usage precautions, technical specifications, and warranty details. Covers models like Arga GM-049, Draglen GM-907, and more.
Preview EAE KNX Panel Bilgilendirme Yazısı: Sistem Bileşenleri ve Kullanım Rehberi
Bu belge, EAE tarafından sunulan KNX panellerinin sistem bileşenlerini (IP Router, Dali Gateway, Switch, Room Control Unit, Dimmer vb.) tanıtan ve ETS yazılımı kurulumu hakkında bilgi veren bir bilgilendirme yazısıdır. Laboratuvar ortamında kullanım ve test senaryolarına odaklanmaktadır.