AIRPLUS WFS2008-2

AIRPLUS 77 Pint Dehumidifier User Manual

Model: WFS2008-2

1. Introduction

Thank you for choosing the AIRPLUS 77 Pint Dehumidifier. This manual provides essential information for the safe and efficient operation of your appliance. Please read it thoroughly before use and retain it for future reference.

This dehumidifier is designed to reduce humidity levels in indoor spaces up to 5000 sq. ft., featuring a 1.3-gallon water tank and options for continuous drainage. It includes functions for dehumidification, drying, and air purification, along with a smart control panel for easy operation.

AIRPLUS Dehumidifier showing 80% humidity before and 40% after dehumidification

Figure 1: Illustration of the dehumidifier's efficiency, reducing humidity from 80% to 40%.

2. Important Safety Instructions

To prevent injury to the user or others and property damage, the following instructions must be followed. Incorrect operation due to ignoring instructions may cause harm or damage.

  • Always connect the unit to a grounded power outlet.
  • Do not operate the unit with a damaged power cord or plug.
  • Do not block the air inlet or outlet.
  • Ensure the unit is placed on a level, stable surface to prevent water overflow.
  • Do not immerse the unit in water or other liquids.
  • Unplug the unit before cleaning or performing any maintenance.
  • Keep children and pets away from the unit during operation.
  • Do not use the unit in areas where flammable gases or combustible materials are present.

3. Product Overview

3.1 Components

The AIRPLUS Dehumidifier is designed for efficient moisture removal. Key components include:

  • Air Inlet/Outlet: For drawing in and expelling air.
  • Control Panel: For setting operating modes and functions.
  • Water Tank: 1.3-gallon capacity for collected moisture.
  • Drainage Port: For connecting the continuous drain hose.
  • Casters: For easy mobility.
AIRPLUS Dehumidifier front view with water tank and dimensions

Figure 2: Front view of the AIRPLUS Dehumidifier, showing the water tank and overall dimensions.

3.2 Control Panel

The smart control panel allows you to manage all functions of the dehumidifier. It features a digital display for temperature and humidity, along with various mode indicators.

AIRPLUS Dehumidifier Smart Control Panel with icons for Dry Clothes, Ionizer, Time Setting, Humidity Setting, Airflow Setting, and On/Off

Figure 3: Detailed view of the Smart Control Panel, illustrating buttons for Dry Clothes, Ionizer Mode, Time Setting, Humidity Setting, Airflow Setting, and Power On/Off.

  • ON/OFF Button: Powers the unit on or off.
  • Humidity Setting: Adjusts the desired humidity level.
  • Airflow Setting (Speed): Controls fan speed (Low, Medium, High).
  • Time Setting (Timer): Sets the 24-hour auto on/off timer.
  • IONIZER Mode: Activates the negative ion function for air purification.
  • Dry Clothes Mode: Optimized setting for drying laundry.
  • Digital Display: Shows current humidity, temperature, and timer settings.
  • Indicators: Full water tank, Defrost, Drying, Ionizer, Timer, Humidity, Speed.

4. Setup

4.1 Placement

Place the dehumidifier on a firm, level surface in the area where dehumidification is needed. Ensure there is at least 8 inches (20 cm) of space around the unit for proper airflow. The unit is suitable for basements, garages, bathrooms, and other large rooms up to 5000 sq. ft.

AIRPLUS Dehumidifier in a living room with a blue circle indicating 5000 sq.ft coverage area

Figure 4: Illustration of the dehumidifier's coverage area, demonstrating its effectiveness in a large living space up to 5000 sq. ft.

4.2 Drainage Options

Your dehumidifier offers two drainage methods:

  1. Manual Drainage (Water Tank):

    The unit collects moisture in its 1.3-gallon (5.5-liter) water tank. When the tank is full, the dehumidifier will beep and automatically shut off. The "FULL" indicator light will illuminate. Empty the tank and place it back correctly to resume operation.

  2. Continuous Drainage (Drain Hose):

    For continuous operation without needing to empty the tank, connect the provided 3.9 ft drain hose to the drainage port at the bottom of the water tank. Ensure the hose is sloped downwards to allow gravity drainage into a floor drain or suitable receptacle. This prevents the tank from filling and the unit from shutting off.

5. Operating Instructions

5.1 Power On/Off

Press the ON/OFF button on the control panel to turn the unit on or off.

5.2 Setting Desired Humidity

Press the Humidity Setting button to adjust the target humidity level. The digital display will show the current humidity. The unit will operate until the set humidity is reached, then cycle on and off to maintain it.

5.3 Fan Speed Adjustment

Press the Airflow Setting button to cycle through fan speeds: Low, Medium, and High. Higher speeds result in faster dehumidification but may produce more noise.

5.4 Operating Modes

AIRPLUS Dehumidifier showing multiple modes: Dry Clothes, Air Circulation, Continuous Dehumidification, Normal Operation

Figure 5: Visual representation of the dehumidifier's multiple operating modes, including Dry Clothes, Air Circulation, Continuous Dehumidification, and Normal Operation.

  • Dehumidification (Normal Operation): The primary function, removing moisture from the air.
  • Dry Clothes Mode: Optimizes airflow and dehumidification for faster drying of laundry. Activate by pressing the Dry Clothes button.
  • IONIZER Mode: Activates the negative ion generator to help purify the air. Press the IONIZER Mode button to enable.
  • Silent Mode (Sleep Mode): Reduces fan speed and dims the display for quiet operation, ideal for bedrooms. The display will screen off in this mode.
AIRPLUS Dehumidifier in a bedroom with 42dB noise level indicated and 'Screenoff In Sleep Mode'

Figure 6: The dehumidifier operating in a bedroom, highlighting its quiet operation at 42dB and the 'Screenoff In Sleep Mode' feature.

5.5 24-Hour Timer

Use the Time Setting button to program the unit to automatically turn on or off after a set number of hours (1-24 hours). This feature provides energy efficiency and convenience.

5.6 Automatic Defrost

The dehumidifier is equipped with defrost sensors. If the coil temperature drops below 45°F (7°C), the unit will automatically enter defrost mode to prevent ice buildup, ensuring proper operation even in colder environments.

6. Maintenance

Regular maintenance ensures optimal performance and extends the lifespan of your dehumidifier.

  • Emptying the Water Tank: When the tank is full, carefully remove it, empty the collected water, and reinsert it securely.
  • Cleaning the Air Filter: The air filter should be cleaned every two weeks or more frequently depending on usage. Remove the filter, wash it with warm, soapy water, rinse thoroughly, and let it air dry completely before reinstalling.
  • Cleaning the Unit Exterior: Wipe the exterior with a soft, damp cloth. Do not use harsh chemicals or abrasive cleaners.
  • Storage: If storing the unit for an extended period, ensure the water tank is empty and clean, and the unit is dry. Store in an upright position in a cool, dry place.

7. Troubleshooting

Before contacting customer support, please refer to the following troubleshooting guide:

ProblemPossible CauseSolution
Unit does not turn on.No power, power cord loose, water tank full or improperly seated.Check power connection. Empty and re-seat water tank correctly.
Unit runs but does not dehumidify.Air filter clogged, humidity setting too high, room temperature too low.Clean air filter. Lower desired humidity setting. Ensure room temperature is above 45°F (7°C).
Water tank fills too quickly / Unit beeps and shuts off frequently.High humidity levels, continuous drainage not set up or hose blocked.This is normal in very humid conditions. If continuous drainage is desired, ensure hose is connected and clear, with proper downward slope.
Unit is noisy.Fan speed too high, unit not on a level surface, air filter clogged.Reduce fan speed. Place unit on a level surface. Clean air filter.
Defrost indicator is on.Coil temperature is too low.This is normal. The unit is automatically defrosting. Operation will resume once defrosting is complete.

8. Specifications

FeatureDetail
BrandAIRPLUS
Model NameWFS2008-2
Dehumidification Capacity77 Pints per Day (AHAM) / 80 Pints per Day (Manufacturer)
Coverage AreaUp to 5000 Sq. Ft.
Water Tank Capacity1.3 Gallons (5.5 Liters)
Product Dimensions (D x W x H)7.87"D x 23.62"W x 13.77"H
Item Weight31.3 pounds
Operation ModeAutomatic
Special FeatureAuto Drain, 24-hour Timer, Ionizer, Dry Clothes Mode, Auto Defrost
ColorWhite

9. Warranty and Customer Support

For warranty information, please refer to the documentation included with your purchase or contact the retailer. If you encounter any issues or have questions regarding your AIRPLUS Dehumidifier, please contact AIRPLUS customer support for assistance.

Contact Information: Please refer to your product packaging or the official AIRPLUS website for the most current customer support contact details.

Related Documents - WFS2008-2

Preview Airplus AP1907P Dehumidifier User Manual
User manual for the Airplus AP1907P 30-pint dehumidifier, covering up to 2000 sq. ft. Includes setup, operation, maintenance, and safety guidelines for home and basement use.
Preview Airplus AP25-2003EE Dehumidifier User Manual
Comprehensive user manual for the Airplus AP25-2003EE dehumidifier, covering product details, operation, care and cleaning, troubleshooting, and technical specifications. Learn how to use and maintain your Airplus dehumidifier for optimal performance.
Preview Airplus AP20-1905EE Dehumidifier: Setup, Operation, and Safety Manual
Comprehensive user manual for the Airplus AP20-1905EE 70-pint dehumidifier, covering setup, safety guidelines, operating modes, timer functions, anion feature, auto-defrost, and maintenance for rooms up to 4,500 sq. ft.
Preview Airplus FDKE3802 2 Speed Dehumidifier User Manual
Comprehensive user manual for the Airplus FDKE3802 2 Speed Dehumidifier, detailing safety warnings, operation instructions, product features, maintenance, and troubleshooting guidance.
Preview Airplus Dehumidifier User Manual: Operation, Care, and Troubleshooting
Comprehensive user manual for the Airplus Dehumidifier, covering product details, operation, cleaning, maintenance, troubleshooting, and technical specifications.
Preview Airplus Dehumidifier AP25-2003EE User Manual
Comprehensive user manual for the Airplus Dehumidifier AP25-2003EE, detailing product features, operation instructions, care and cleaning procedures, troubleshooting tips, and technical specifications.